• ISO 10780:1994

    Current The latest, up-to-date edition.

    Stationary source emissions — Measurement of velocity and volume flowrate of gas streams in ducts

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English, French

    Published date:  10-11-1994

    Publisher:  International Organization for Standardization

    Add To Cart

    Abstract - (Show below) - (Hide below)

    Specifies manual methods for determining the velocity and volume flowrate of gas streams in ducts, stacks and chimneys vented to the atmosphere. Specifies the use of two types of Pitot tubes, type L und type S, for determining the velocity and the volume flowrate for each type of Pitot tube. Applies to gas streams with essentially constant density, temperature, flowrate and pressure at the sampling point.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher International Organization for Standardization
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS ISO 2889:2010 Sampling airborne radioactive materials from the stacks and ducts of nuclear facilities
    UNE-EN ISO 16170:2017 In situ test methods for high efficiency filter systems in industrial facilities (ISO 16170:2016, Corrected version 2017-04)
    11/30239461 DC : 0 BS EN ISO 16911-1 - STATIONARY SOURCE EMISSIONS - DETERMINATION OF VELOCITY AND VOLUMETRIC FLOW RATE IN DUCTS - PART 1: MANUAL REFERENCE METHOD
    BS EN 62282-3-200:2016 Fuel cell technologies Stationary fuel cell power systems. Performance test methods
    BS ISO 25597:2013 Stationary source emissions. Test method for determining PM2$d,5 and PM10 mass in stack gases using cyclone samplers and sample dilution
    FD X43 319 : 2010 FD STATIONARY SOURCE EMISSIONS - GUIDE FOR SAMPLING AND ANALYSIS OF VOLATILE ORGANIC COMPOUNDS
    I.S. EN ISO 16170:2016 IN SITU TEST METHODS FOR HIGH EFFICIENCY FILTER SYSTEMS IN INDUSTRIAL FACILITIES (ISO 16170:2016, CORRECTED VERSION 2017-04)
    CSA N288.5 : 2011 : R2016 EFFLUENT MONITORING PROGRAMS AT CLASS 1 NUCLEAR FACILITIES AND URANIUM MINES AND MILLS
    I.S. EN 62282-3-2:2006 FUEL CELL TECHNOLOGIES - PART 3-2: STATIONARY FUEL CELL POWER SYSTEMS - PERFORMANCE TEST METHODS
    ISO 12141:2002 Stationary source emissions — Determination of mass concentration of particulate matter (dust) at low concentrations — Manual gravimetric method
    ISO 16170:2016 In situ test methods for high efficiency filter systems in industrial facilities
    S.R. CWA 45547:2004 MANUAL FOR DETERMINATION OF COMBINED HEAT AND POWER (CHP)
    DIN EN ISO 16170:2013-07 (Draft) IN SITU TEST METHODS FOR HIGH EFFICIENCY FILTER SYSTEMS IN INDUSTRIAL FACILITIES (ISO 16170:2016)
    EN 62282-3-200:2016 Fuel cell technologies - Part 3-200: Stationary fuel cell power systems - Performance test methods
    08/30161739 DC : DRAFT MAY 2008 BS EN ISO 11771 - AIR QUALITY - DETERMINATION OF TIME-AVERAGED MASS EMISSIONS AND EMISSION FACTORS - GENERAL APPROACH
    ISO 25597:2013 Stationary source emissions Test method for determining PM2,5 and PM10 mass in stack gases using cyclone samplers and sample dilution
    14/30280137 DC : 0 BS EN 62282-3-200 ED 2.0 - FUEL CELL TECHNOLOGIES - PART 3-200: STATIONARY FUEL CELL POWER SYSTEMS - PERFORMANCE TEST METHODS
    12/30230597 DC : 0 BS ISO 25597 - STATIONARY SOURCE EMISSIONS - TEST METHOD FOR DETERMINING PM2,5 AND PM10 MASS IN STACK GASES USING CYCLONE SAMPLERS AND SAMPLE DILUTION
    NF ISO 2889 : 2010 SAMPLING AIRBORNE RADIOACTIVE MATERIALS FROM THE STACKS AND DUCTS OF NUCLEAR FACILITIES
    14/30303591 DC : 0 BS EN ISO 19694-1 - STATIONARY SOURCE EMISSIONS - DETERMINATION OF GREENHOUSE GAS (GHG) EMISSIONS IN ENERGY-INTENSIVE INDUSTRIES - PART 1: GENERAL ASPECTS
    BS EN ISO 11771:2010 Air quality. Determination of time-averaged mass emissions and emission factors. General approach
    I.S. EN ISO 13833:2013 STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE RATIO OF BIOMASS (BIOGENIC) AND FOSSIL-DERIVED CARBON DIOXIDE - RADIOCARBON SAMPLING AND DETERMINATION (ISO 13833:2013)
    ISO 19867-1:2018 Clean cookstoves and clean cooking solutions — Harmonized laboratory test protocols — Part 1: Standard test sequence for emissions and performance, safety and durability
    FD X43 131 : 2005 FD STATIONARY SOURCE EMISSIONS - PRACTICAL GUIDANCE FOR ESTIMATING THE INCERTAINTY IN MEASUREMENT OF POLLUTANT CONCENTRATIONS - PART 1: GENERAL - PART 2: AUTOMATIC MEASUREMENT - PART 3: DUST MEASUREMENT - PART 4: MANUAL MEASUREMENT OF A PARTICULATE GASEOUS POLLUTANT SPARGING - PART 5: MANUAL MEASUREMENT OF POLYCYCLIC AROMATIC HYDROCARBONS AND DIOXINS/FURARES - PART 6: MOISTURE
    ASTM D 6331 : 2016 : REDLINE Standard Test Method for Determination of Mass Concentration of Particulate Matter from Stationary Sources at Low Concentrations (Manual Gravimetric Method)
    VDI 3460 Blatt 1:2014-02 Emission control - Thermal waste treatment - Fundamentals
    VDI 3478 Blatt 2:2008-04 Biological waste gas purification - Biological trickle bed-reactors
    DIN EN ISO 16170:2017-05 IN SITU TEST METHODS FOR HIGH EFFICIENCY FILTER SYSTEMS IN INDUSTRIAL FACILITIES (ISO 16170:2016)
    VDI 3880:2011-10 Olfactometry - Static sampling
    DIN EN ISO 16170 E : 2017 IN SITU TEST METHODS FOR HIGH EFFICIENCY FILTER SYSTEMS IN INDUSTRIAL FACILITIES (ISO 16170:2016)
    17/30335786 DC : 0 BS ISO 19867-1 - CLEAN COOKSTOVES AND CLEAN COOKING SOLUTIONS - HARMONIZED LABORATORY TEST PROTOCOLS - PART 1: STANDARD TEST SEQUENCE FOR EMISSIONS AND PERFORMANCE, SAFETY AND DURABILITY
    10/30173701 DC : 0 BS EN 62282-3-200 - FUEL CELL TECHNOLOGIES - PART 3-200: STATIONARY FUEL CELL POWER SYSTEMS - PERFORMANCE TEST METHODS
    03/315090 DC : DRAFT SEP 2003 ISO 15713 - STATIONARY SOURCE EMISSIONS - SAMPLING AND DETERMINATION OF GASEOUS-FLUORIDE CONTENT
    BS ISO 12141:2002 Stationary source emissions. Determination of mass concentration of particulate matter (dust) at low concentrations. Manual gravimetric method
    BS ISO 18466:2016 Stationary source emissions. Determination of the biogenic fraction in C O2 in stack gas using the balance method
    11/30227244 DC : 0 BS EN ISO 13833 - STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE RATIO OF BIOMASS (BIOGENIC) AND FOSSIL-DERIVED CARBON DIOXIDE - RADIOCARBON SAMPLING AND DETERMINATION
    07/30134856 DC : DRAFT AUG 2007 BS ISO 2889 - SAMPLING AIRBORNE RADIOACTIVE MATERIALS FROM THE STACKS AND DUCTS OF NUCLEAR FACILITIES
    99/565449 DC : DRAFT OCT 99 DRAFT BS EN 13725 - AIR QUALITY - DETERMINATION OF ODOUR CONCENTRATION BY DYNAMIC OFFACTOMETRY
    BS ISO 15713:2006 Stationary source emissions. Sampling and determination of gaseous fluoride content
    16/30346835 DC : 0 BS ISO 20789 - ANAESTHETIC AND RESPIRATORY EQUIPMENT - PASSIVE HUMIDIFIERS
    02/203214 DC : DRAFT MAR 2002 IEC 62282-3-2 - FUEL CELL TECHNOLOGIES - PART 3-2: STATIONARY FUEL CELL POWER PLANTS - TEST METHODS FOR THE PERFORMANCE
    S.R. CEN/TR 17078:2017 STATIONARY SOURCE EMISSIONS - GUIDANCE ON THE APPLICATION OF EN ISO 16911-1
    ISO 18466:2016 Stationary source emissions — Determination of the biogenic fraction in CO2 in stack gas using the balance method
    ISO 15713:2006 Stationary source emissions Sampling and determination of gaseous fluoride content
    IEC 62282-3-200:2015 Fuel cell technologies - Part 3-200: Stationary fuel cell power systems - Performance test methods
    EN ISO 13833:2013 Stationary source emissions - Determination of the ratio of biomass (biogenic) and fossil-derived carbon dioxide - Radiocarbon sampling and determination (ISO 13833:2013)
    ONORM EN 13725 : 2006 AIR QUALITY - DETERMINATION OF ODOUR CONCENTRATION BY DYNAMIC OLFACTOMETRY
    UNI EN ISO 16911-1 : 2013 STATIONARY SOURCE EMISSIONS - MANUAL AND AUTOMATIC DETERMINATION OF VELOCITY AND VOLUME FLOW RATE IN DUCTS - PART 1: MANUAL REFERENCE METHOD
    BS EN ISO 16170:2016 In situ test methods for high efficiency filter systems in industrial facilities
    DIN EN ISO 11771:2011-04 Air quality - Determination of time-averaged mass emissions and emission factors - General approach (ISO 11771:2010)
    13/30248319 DC : 0 BS EN ISO 16170 - IN SITU TEST METHODS FOR VERY HIGH EFFICIENCY FILTER SYSTEMS IN INDUSTRIAL FACILITIES
    BS EN ISO 16911-1:2013 Stationary source emissions. Manual and automatic determination of velocity and volume flow rate in ducts Manual reference method
    BS EN ISO 13833:2013 Stationary source emissions. Determination of the ratio of biomass (biogenic) and fossil-derived carbon dioxide. Radiocarbon sampling and determination
    BS ISO 9096:2017 Stationary source emissions. Manual determination of mass concentration of particulate matter
    BS EN 62282-3-2:2006 Fuel cell technologies Stationary fuel cell power systems. Performance test methods
    CSA N288.5 : 2011 EFFLUENT MONITORING PROGRAMS AT CLASS 1 NUCLEAR FACILITIES AND URANIUM MINES AND MILLS
    UNI EN ISO 11771 : 2011 AIR QUALITY - DETERMINATION OF TIME-AVERAGED MASS EMISSIONS AND EMISSION FACTORS - GENERAL APPROACH
    UNI EN ISO 13833 : 2013 STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE RATIO OF BIOMASS (BIOGENIC) AND FOSSIL-DERIVED CARBON DIOXIDE - RADIOCARBON SAMPLING AND DETERMINATION
    NF ISO 15713 : 2006 STATIONARY SOURCE EMISSIONS - SAMPLING AND DETERMINATION OF GASEOUS FLUORIDE CONTENT
    ISO 2889:2010 Sampling airborne radioactive materials from the stacks and ducts of nuclear facilities
    ISO 14164:1999 Stationary source emissions — Determination of the volume flowrate of gas streams in ducts — Automated method
    ISO 16911-1:2013 Stationary source emissions — Manual and automatic determination of velocity and volume flow rate in ducts — Part 1: Manual reference method
    UNE-EN ISO 16911-1:2013 Stationary source emissions - Manual and automatic determination of velocity and volume flow rate in ducts - Part 1: Manual reference method (ISO 16911-1:2013)
    ISO 11771:2010 Air quality Determination of time-averaged mass emissions and emission factors General approach
    ISO 13833:2013 Stationary source emissions Determination of the ratio of biomass (biogenic) and fossil-derived carbon dioxide Radiocarbon sampling and determination
    EN 13725:2003/AC:2006 AIR QUALITY - DETERMINATION OF ODOUR CONCENTRATION BY DYNAMIC OLFACTOMETRY
    EN ISO 16911-1:2013 Stationary source emissions - Manual and automatic determination of velocity and volume flow rate in ducts - Part 1: Manual reference method (ISO 16911-1:2013)
    NF EN 13725 : 2003 AIR QUALITY - DETERMINATION OF ODOUR CONCENTRATION BY DYNAMIC OLFACTOMETRY
    EN ISO 11771 : 2010 Air quality - Determination of time-averaged mass emissions and emission factors - General approach (ISO 11771:2010)
    I.S. EN 13725:2003 AIR QUALITY - DETERMINATION OF ODOUR CONCENTRATION BY DYNAMIC OLFACTOMETRY
    PD CEN/TR 17078:2017 Stationary source emissions. Guidance on the application of EN ISO 16911-1
    UNE-EN ISO 11771:2011 Air quality - Determination of time-averaged mass emissions and emission factors - General approach (ISO 11771:2010)
    DIN EN ISO 13833:2013-07 STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE RATIO OF BIOMASS (BIOGENIC) AND FOSSIL-DERIVED CARBON DIOXIDE - RADIOCARBON SAMPLING AND DETERMINATION (ISO 13833:2013)
    ISO 10396:2007 Stationary source emissions — Sampling for the automated determination of gas emission concentrations for permanently-installed monitoring systems
    17/30326671 DC : 0 BS ISO 27919-1 - CARBON DIOXIDE CAPTURE - PART 1: PERFORMANCE EVALUATION METHODS FOR POST-COMBUSTION CO[2] CAPTURE INTEGRATED WITH A POWER PLANT
    UNE-EN ISO 13833:2013 Stationary source emissions - Determination of the ratio of biomass (biogenic) and fossil-derived carbon dioxide - Radiocarbon sampling and determination (ISO 13833:2013)
    15/30300279 DC : 0 BS ISO 80601-2-74 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-74: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RESPIRATORY HUMIDIFYING EQUIPMENT
    BS ISO 14164:1999 Stationary source emissions. Determination of the volume flowrate of gas streams in ducts. Automated method
    DIN EN ISO 16911-1:2013-06 Stationary source emissions - Manual and automatic determination of velocity and volume flow rate in ducts - Part 1: Manual reference method (ISO 16911-1:2013); German version EN ISO 16911-1:2013
    BS ISO 10396:2007 Stationary source emissions. Sampling for the automated determination of gas emission concentrations for permanently-installed monitoring systems
    16/30275160 DC : 0 BS ISO 18466 - STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE BIOGENIC FRACTION IN CO[2]IN STACK GAS USING THE BALANCE METHOD
    I.S. EN ISO 16911-1:2013 STATIONARY SOURCE EMISSIONS - MANUAL AND AUTOMATIC DETERMINATION OF VELOCITY AND VOLUME FLOW RATE IN DUCTS - PART 1: MANUAL REFERENCE METHOD (ISO 16911-1:2013)
    I.S. EN 62282-3-200:2016 FUEL CELL TECHNOLOGIES - PART 3-200: STATIONARY FUEL CELL POWER SYSTEMS - PERFORMANCE TEST METHODS
    NF ISO 10396 : 2007 STATIONARY SOURCE EMISSIONS - SAMPLING FOR THE AUTOMATED DETERMINATION OF GAS EMISSION CONCENTRATIONS FOR PERMANENTLY-INSTALLED MONITORING SYSTEMS
    I.S. EN ISO 11771:2010 AIR QUALITY - DETERMINATION OF TIME-AVERAGED MASS EMISSIONS AND EMISSION FACTORS - GENERAL APPROACH
    IEC 62282-3-2:2006 Fuel cell technologies - Part 3-2: Stationary fuel cell power systems - Performance test methods
    EN 62282-3-2:2006 Fuel cell technologies - Part 3-2: Stationary fuel cell power systems - Performance test methods
    CEN/TR 17078:2017 Stationary source emissions - Guidance on the application of EN ISO 16911-1

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 3966:2008 Measurement of fluid flow in closed conduits Velocity area method using Pitot static tubes
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective