Alarm systems. Intrusion and hold-up systems Alarm verification. Methods and principles
Hardcopy , PDF
English
31-07-2014
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Overview
5 Parameter variation
6 General recommendations for I&HAS incorporating
alarm verification
7 Sequential verification of intruder alarms
8 Sequential verification of hold-up alarms
9 Audible alarm verification
10 Visual alarm verification
11 ATS faults
Annex A (informative) - Equipment specifications
Annex B (informative) - Equipment test procedures
Bibliography
Gives recommendations for the addition and use of alarm verification technology in Intrusion and Hold-up Alarm Systems (I&HAS) installed to comply with EN 50131-1.
Committee |
GW/1/2
|
DevelopmentNote |
Supersedes 10/30227151 DC. (07/2014)
|
DocumentType |
Standard
|
Pages |
32
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Technical Specification is available for use where alarm verification methods are considered necessary. It provides recommendations for the addition and use of alarm verification technology in Intrusion and Hold-up Alarm Systems (I&HAS) installed to comply with EN 50131-1. These recommendations should be incorporated into the respective standards in the EN 5013x series. This Technical Specification does not detail methods of alarm verification relying solely on Alarm Receiving Centre (ARC) procedures, but does not preclude their use. This Technical Specification describes alarm verification methods that could be applied and details applicable to system and equipment design. The framework limits the range of options in order to provide for local regulations and circumstances, whilst permitting a standardised approach to equipment design. This Technical Specification also provides (in Annex A) recommendations for equipment in order to permit the manufacture of standardised equipment to provide the functionality needed by an I&HAS incorporating alarm verification technology. The associated guidelines for use in ARCs to monitor notification from such I&HAS can be found in EN 50518-3. NOTE Alarm verification may also be referred to as “alarm confirmation??.
Standards | Relationship |
CLC/TS 50131-9:2014 | Identical |
CLC/TS 50131-2-7-1:2009 | Alarm systems - Intrusion and hold-up systems - Part 2-7-1: Intrusion detectors - Glass break detectors (acoustic) |
CLC/TS 50131-7:2010 | Alarm systems - Intrusion and hold-up systems - Part 7: Application guidelines |
EN 50136-1:2012 | Alarm systems - Alarm transmission systems and equipment - Part 1: General requirements for alarm transmission systems |
EN 50132-1 : 2010 COR 2010 | ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 1: SYSTEM REQUIREMENTS |
EN 50131-10:2014 | Alarm systems - Intrusion and hold-up systems - Part 10: Application specific requirements for Supervised Premises Transceiver (SPT) |
EN 50131-3:2009 | Alarm systems - Intrusion and hold-up systems - Part 3: Control and indicating equipment |
EN 50518-3:2013 | MONITORING AND ALARM RECEIVING CENTRE - PART 3: PROCEDURES AND REQUIREMENTS FOR OPERATION |
CLC/TS 50131-11:2012 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 11: HOLD-UP DEVICES |
EN 50131-1:2006/A2:2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
EN 50132-7:2012 | Alarm systems - CCTV surveillance systems for use in security applications - Part 7: Application guidelines |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.