Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Systems and equipment to be protected
5 Overvoltages in a PV installation
6 Installation and location of SPDs
7 Equipotential
8 Surge protective devices (SPD) in PV installations
9 Requirements for the implementation of SPDs
10 Maintenance
Annex A (informative) - Determination of the value of
        I[imp] or I[n] for SPDs for different structures
        protected by a LPS according to a simplified
        approach
Annex B (informative) - Characteristic of a PV source
Annex C (normative) - Simplified risk assessment based
        on EN 62305-2
Bibliography

Specifies the principles for selection, location, coordination and operation of SPDs to be connected to PV installations.

Committee
PEL/37
DevelopmentNote
Supersedes DD CLC/TS 50539-12. (07/2014)
DocumentType
Standard
Pages
38
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

This Technical Specification describes the principles for selection, location, coordination and operation of SPDs to be connected to PV installations. The d.c. side is rated up to 1 500 V d.c. and the a.c. side, if any, is rated up to 1 000 V rms 50 Hz.

The electrical installation starts from a PV generator or a set of interconnected PV modules with their cables, provided by the PV generator manufacturer, up to the user installation or the utility supply point.

For PV installations including batteries, additional requirements will be necessary.

NOTE 1 HD 60364-7-712, CLC/TS 61643-12 and EN 62305-4 are also applicable.

NOTE 2 This Technical Specification deals only with SPDs, and not with SPDs components integrated inside equipment.

Standards Relationship
CLC/TS 50539-12:2013 Identical

IEC 60364-5-54:2011 Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors
EN 60904-3:2016 Photovoltaic devices - Part 3: Measurement principles for terrestrial photovoltaic (PV) solar devices with reference spectral irradiance data
IEC 60364-7-712:2017 Low voltage electrical installations - Part 7-712: Requirements for special installations or locations - Solar photovoltaic (PV) power supply systems
HD 60364-4-443:2016 Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances - Clause 443: Protection against transient overvoltages of atmospheric origin or due to switching
EN 62305-4:2011/AC:2016 PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES (IEC 62305-4:2010)
IEC 61730-2:2016 Photovoltaic (PV) module safety qualification - Part 2: Requirements for testing
IEC 61643-12:2008 Low-voltage surge protective devices - Part 12: Surge protective devices connected to low-voltage power distribution systems - Selection and application principles
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control
HD 60364-5-54:2011/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS
IEC 61643-21:2000+AMD1:2008+AMD2:2012 CSV Low voltage surge protective devices - Part 21: Surge protective devices connected to telecommunications and signalling networks - Performance requirements and testing methods
IEC 62561-1:2017 Lightning protection system components (LPSC) - Part 1: Requirements for connection components
EN 62305-4:2011/AC:2016-11 Protection against lightning - Part 4: Electrical and electronic systems within structures
IEC 62305-1:2010 Protection against lightning - Part 1: General principles
EN 62305-3:2011 Protection against lightning - Part 3: Physical damage to structures and life hazard
HD 60364-5-534:2016 Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control - Clause 534: Devices for protection against transient overvoltages
IEC 61643-22:2015 Low-voltage surge protective devices - Part 22: Surge protective devices connected to telecommunications and signalling networks - Selection and application principles
IEC 61643-1:2005 Low-voltage surge protective devices - Part 1: Surge protective devices connected to low-voltage power distribution systems - Requirements and tests
IEC 60364-4-44:2007+AMD1:2015 CSV Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances
EN 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
HD 60364-7-712:2016 Low-voltage electrical installations - Part 7-712: Requirements for special installations or locations - Photovoltaic (PV) systems
IEC 60904-3:2016 Photovoltaic devices - Part 3: Measurement principles for terrestrial photovoltaic (PV) solar devices with reference spectral irradiance data
EN 61643-21:2001/A2:2013 LOW VOLTAGE SURGE PROTECTIVE DEVICES - PART 21: SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALLING NETWORKS - PERFORMANCE REQUIREMENTS AND TESTING METHODS (IEC 61643-21:2000/A2:2012)
EN 62109-1 : 2010 SAFETY OF POWER CONVERTERS FOR USE IN PHOTOVOLTAIC POWER SYSTEMS - PART 1: GENERAL REQUIREMENTS
EN 62305-2:2012 Protection against lightning - Part 2: Risk management
EN 62561-1:2017 Lightning Protection System Components (LPSC) - Part 1: Requirements for connection components
CLC/TS 61643-12:2009 LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 12: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER DISTRIBUTION SYSTEMS - SELECTION AND APPLICATION PRINCIPLES
IEC 62305-4:2010 Protection against lightning - Part 4: Electrical and electronic systems within structures
IEC 62305-2:2010 Protection against lightning - Part 2: Risk management
IEC 62109-1:2010 Safety of power converters for use in photovoltaic power systems - Part 1: General requirements
EN 50539-11 : 2013 AMD 1 2014 LOW-VOLTAGE SURGE PROTECTIVE DEVICES - SURGE PROTECTIVE DEVICES FOR SPECIFIC APPLICATION INCLUDING D.C. - PART 11: REQUIREMENTS AND TESTS FOR SPDS IN PHOTOVOLTAIC APPLICATIONS
IEC 62305-3:2010 Protection against lightning - Part 3: Physical damage to structures and life hazard
CLC/TS 61643-22:2016 Low-voltage surge protective devices - Part 22: Surge protective devices connected to telecommunications and signalling networks - Selection and application principles