PD ISO/IEC TR 18047-6:2011
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Information technology. Radio frequency identification device conformance test methods Test methods for air interface communications at 860 MHz to 960 MHz
Hardcopy , PDF
31-01-2013
English
28-02-2011
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions, symbols and abbreviated terms
4 Setup of test equipment
5 Conformance tests for ISO/IEC 18000-6 Type A
6 Conformance tests for ISO/IEC 18000-6 Type B
7 Conformance tests for ISO/IEC 18000-6 Type C
8 Conformance tests for ISO/IEC 18000-6 Type D
9 Conformance tests for ISO/IEC 18000-6 Battery
Assisted Passive (BAP) Type C
10 Conformance tests for ISO/IEC 18000-6 Sensor support
Annex A (informative) - Test measurement site
Annex B (normative) - Command coding for conformance
tests for the different types of ISO/IEC 18000-6
Annex C (normative) - State-transition tables
Annex D (normative) - Technical performance of the
digital oscilloscope
Annex E (normative) - Technical performance of the
spectrum analyser
Annex F (normative) - Tag emulator
Annex G (informative) - Measurement examples
Annex H (normative) - Technical performance of the vector
signal generator
Annex I (normative) - Reference antenna
Bibliography
Describes test methods for determining the conformance of radio frequency identification (RFID) devices (tags and interrogators) for item management with the specifications given in ISO/IEC 18000-6, but does not apply to the testing of conformity with regulatory or similar requirements.
Committee |
IST/34
|
DocumentType |
Standard
|
Pages |
84
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This part of ISO/IEC TR 18047 defines test methods for determining the conformance of radio frequency identification (RFID) devices (tags and interrogators) for item management with the specifications given in ISO/IEC 18000-6, but does not apply to the testing of conformity with regulatory or similar requirements.
The test methods require only that the mandatory functions, and any optional functions which are implemented, be verified. This can, in appropriate circumstances, be supplemented by further, application-specific functionality criteria that are not available in the general case.
The interrogator and tag conformance parameters in this part of ISO/IEC TR 18047 are the following:
type-specific conformance parameters including nominal values and tolerances;
parameters that apply directly affecting system functionality and inter-operability.
The following are not included in this part of ISO/IEC TR 18047:
parameters that are already included in regulatory test requirements;
high-level data encoding conformance test parameters (these are specified in ISO/IEC 15962).
Unless otherwise specified, the tests in this part of ISO/IEC TR 18047 are to be applied exclusively to RFID tags and interrogators defined in ISO/IEC 18000-6.
Clause 5 describes all necessary conformance tests for ISO/IEC 18000-6 Type A.
Clause 6 describes all necessary conformance tests for ISO/IEC 18000-6 Type B.
Clause 7 describes all necessary conformance tests for ISO/IEC 18000-6 Type C.
Clause 8 describes all necessary conformance tests for ISO/IEC 18000-6 Type D.
Clause 9 describes all necessary conformance tests for ISO/IEC 18000-6 Type C Battery Assisted Passive (BAP), whereas optional features will only be tested when supported.
Clause 10 describes all necessary conformance tests for ISO/IEC 18000-6 Type C Sensor support, whereas optional features will only be tested when supported.
Standards | Relationship |
ISO/IEC TR 18047-6:2011 | Identical |
ISO/IEC 15962:2013 | Information technology Radio frequency identification (RFID) for item management Data protocol: data encoding rules and logical memory functions |
ISO/IEC 18000-6:2013 | Information technology — Radio frequency identification for item management — Part 6: Parameters for air interface communications at 860 MHz to 960 MHz General |
TR 102 273-3 : 1.2.1 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); IMPROVEMENT ON RADIATED METHODS OF MEASUREMENT (USING TEST SITE) AND EVALUATION OF THE CORRESPONDING MEASUREMENT UNCERTAINTIES; PART 3: ANECHOIC CHAMBER WITH A GROUND PLANE |
ISO/IEC 18046-1:2011 | Information technology — Radio frequency identification device performance test methods — Part 1: Test methods for system performance |
ISO/IEC 18046-2:2011 | Information technology Radio frequency identification device performance test methods Part 2: Test methods for interrogator performance |
ISO/IEC 18046-3:2012 | Information technology Radio frequency identification device performance test methods Part 3: Test methods for tag performance |
TR 102 273-2 : 1.2.1 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); IMPROVEMENT ON RADIATED METHODS OF MEASUREMENT (USING TEST SITE) AND EVALUATION OF THE CORRESPONDING MEASUREMENT UNCERTAINTIES; PART 2: ANECHOIC CHAMBER |
TR 102 273-4 : 1.2.1 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); IMPROVEMENT ON RADIATED METHODS OF MEASUREMENT (USING TEST SITE) AND EVALUATION OF THE CORRESPONDING MEASUREMENT UNCERTAINTIES; PART 4: OPEN AREA TEST SITE |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.