Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Principle
6 Calibration and validation of the AMS
  (QAL2)
7 Ongoing quality assurance during operation
  (QAL3)
8 Annual Surveillance Test (AST)
9 Documentation
Annex A (normative) - QAL2 and AST functional test
        of AMS
Annex B (normative) - Test of linearity
Annex C (informative) - Control Charts
Annex D (informative) - Documentation
Annex E (informative) - Example of calculation of the
        calibration function and of the variability test
Annex F (informative) - Example of calculation of the
        standard deviation s[AMS] of the AMS at zero
        and span level
Annex G (informative) - Example of using the calibration
        function and the variability test in the AST
Annex H (informative) - CUSUM charts field form (drift)
Annex I (informative) - Implementation of QAL1
Annex J (normative) - k[v] and t[0,95] values
Annex K (informative) - Significant technical changes
Bibliography

Defines procedures for establishing quality assurance levels (QAL) for automated measuring systems (AMS) installed on industrial plants for the determination of the flue gas components and other flue gas parameters.

Committee
TC 264
DocumentType
Draft
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy

Standards Relationship
12/30259213 DC : 0 Identical
01/562616 DC : DRAFT JUL 2001 Identical

03/312903 DC : DRAFT SEP 2003 EN 14792 - STATIONARY SOURCE EMISSIONS - DETERMINATION OF MASS CONCENTRATION OF NITROGEN OXIDES (NO[X]) - REFERENCE METHOD: CHEMILUMINESCENCE
04/30107778 DC : DRAFT JAN 2004 EN 14884 - AIR QUALITY - STATIONARY SOURCE EMISSIONS - DETERMINATION OF TOTAL MERCURY - AUTOMATED MEASURING SYSTEMS
14/30303591 DC : 0 BS EN ISO 19694-1 - STATIONARY SOURCE EMISSIONS - DETERMINATION OF GREENHOUSE GAS (GHG) EMISSIONS IN ENERGY-INTENSIVE INDUSTRIES - PART 1: GENERAL ASPECTS
PREN 14790 : DRAFT 2014 STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE WATER VAPOUR IN DUCTS - STANDARD REFERENCE METHOD
VDI 3884 Blatt 1:2015-02 Olfactometry - Determination of odour concentration by dynamic olfactometry - Supplementary instructions for application of DIN EN 13725
VDI 2286 Blatt 1:2013-08 Emission control - Electrolytic aluminium reduction process
VDI 3460 Blatt 1:2014-02 Emission control - Thermal waste treatment - Fundamentals
VDI 3455:2013-08 Emission control - High-volume car body painting plants
VDI 3898:2013-01 Emission control - Plants for dry mechanical, physio-chemical, thermal and biological soil treatment
VDI 2102 Blatt 2:2013-04 Emission control - Copper and copper alloy melting plants
14/30293551 DC : 0 BS EN 14790 - STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE WATER VAPOUR IN DUCTS - STANDARD REFERENCE METHOD
14/30293548 DC : 0 BS EN 14792 - STATIONARY SOURCE EMISSIONS - DETERMINATION OF MASS CONCENTRATION OF NITROGEN OXIDES - STANDARD REFERENCE METHOD: CHEMILUMINESCENCE
14/30293541 DC : 0 BS EN 14789 - STATIONARY SOURCE EMISSIONS - DETERMINATION OF VOLUME CONCENTRATION OF OXYGEN (O2) - STANDARD REFERENCE METHOD - PARAMAGNETISM
02/565203 DC : DRAFT DEC 2002 BS EN 13284-2 - STATIONARY SOURCE EMISSIONS - DETERMINATION OF LOW RANGE MASS CONCENTRATION OF DUST - PART 2: AUTOMATED MEASURING SYSTEMS
PREN 14789 : DRAFT 2014 STATIONARY SOURCE EMISSIONS - DETERMINATION OF VOLUME CONCENTRATION OF OXYGEN - STANDARD REFERENCE METHOD: PARAMAGNETISM
03/312902 DC : DRAFT SEP 2003 EN 14791 - STATIONARY SOURCE EMISSIONS - DETERMINATION OF MASS CONCENTRATION OF SULPHUR DIOXIDE - REFERENCE METHOD

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
EN 15267-3:2007 Air quality - Certification of automated measuring systems - Part 3: Performance criteria and test procedures for automated measuring systems for monitoring emissions from stationary sources
CEN/TR 15983:2010 Stationary source emissions - Guidance on the application of EN 14181:2004
ISO 14956:2002 Air quality — Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty
EN 15267-2:2009 Air quality - Certification of automated measuring systems - Part 2: Initial assessment of the AMS manufacturer’s quality management system and post certification surveillance for the manufacturing process
ISO 11095:1996 Linear calibration using reference materials
EN 15259:2007 Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
EN 13284-1:2017 Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
EN 13284-2:2017 Stationary source emissions - Determination of low range mass concentration of dust - Part 2: Quality assurance of automated measuring systems
EN ISO 14956:2002 Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty (ISO 14956:2002)
ENV 13005 : DRAFT 1999 GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT
EN 14385:2004 Stationary source emissions - Determination of the total emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, TI and V
EN 14792:2017 Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: chemiluminescence
EN 15267-1:2009 Air quality - Certification of automated measuring systems - Part 1: General principles
ISO 3534-1:2006 Statistics — Vocabulary and symbols — Part 1: General statistical terms and terms used in probability

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.