PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTANCE AND/OR SMOKE CONTROL CHARACTERISTICS
12-01-2013
01-10-2014
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Performance characteristics and special requirements
5 Classification and designation
6 Instructions for installation, operation and
maintenance
7 Evaluation of conformity
8 Cascading ITT and factory production control (FPC)
9 Labeling and Marking
Annex A (informative) - Form for designation and
classification of performances
Annex B (normative) - Inspection and maintenance
Annex ZA (informative) - Clauses of this European
Standard addressing the
provisions of the EU
Construction Product Directive
Annex ZB (Informative) - Relationship of this European
Standard and the Essential
Requirements of EU Directive
2006/42/EC
Annex ZC (Informative) - Relationship of this European
Standard and the Essential
Requirements of EU Directive
2004/108/EC
Annex ZD (informative) - Relationship between this
European Standard and the
Essential Requirements of EU
Directive 2006/95/EC
Specifies material independent, safety and performance requirements related to fire resistance and/or smoke control characteristics that are applicable to industrial-/commercial-/garage doors (as defined in EN 13241-1), pedestrian doorsets and openable windows (as defined in EN 14351-1 and/or prEN 14351-2).
| Committee |
TC 33
|
| DocumentType |
Draft
|
| PublisherName |
Comite Europeen de Normalisation
|
| Status |
Superseded
|
| Standards | Relationship |
| DIN EN 16034:2014-12 | Identical |
| 10/30211850 DC : 0 | Identical |
| BS 8524-1:2013 | Active fire curtain barrier assemblies Specification |
| PREN 14351-2 : DRAFT 2014 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 2: INTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND /OR SMOKE LEAKAGE CHARACTERISTICS |
| DIN EN 16035:2013-03 | Hardware performance sheet (HPS) - Identification and summary of test evidence to facilitate the interchangeability of building hardware for application to fire resisting and/or smoke control doorsets and/or openable windows |
| I.S. EN 16035:2012 | HARDWARE PERFORMANCE SHEET (HPS) - IDENTIFICATION AND SUMMARY OF TEST EVIDENCE TO FACILITATE THE INTER-CHANGEABILITY OF BUILDING HARDWARE FOR APPLICATION TO FIRE RESISTING AND/OR SMOKE CONTROL DOORSETS AND/OR OPENABLE WINDOWS |
| DIN EN 1191:2013-04 | Windows and doors - Resistance to repeated opening and closing - Test method |
| BS EN 1191:2012 | Windows and doors. Resistance to repeated opening and closing. Testmethod |
| I.S. EN 1191:2012 | WINDOWS AND DOORS - RESISTANCE TO REPEATED OPENING AND CLOSING - TEST METHOD |
| BS 6510:2010 | Steel-framed windows and glazed doors. Specification |
| 10/30211853 DC : 0 | BS EN 16035 - HARDWARE PERFORMANCE SHEET (HPS) - IDENTIFICATION AND SUMMARY OF TEST EVIDENCE TO FACILITATE THE INTERCHANGEABILITY OF BUILDING HARDWARE FOR APPLICATION TO FIRE RESISTING AND SMOKE CONTROL DOORSETS AND OPENABLE WINDOWS |
| BS 8524-2:2013 | Active fire curtain barrier assemblies Code of practice for application, installation and maintenance |
| BS EN 16035:2012 | Hardware performance sheet (HPS). Identification and summary of test evidence to facilitate the inter-changeability of building hardware for application to fire resisting and/or smoke control doorsets and/or openable windows |
| BS EN 1634-1 : 2014 | FIRE RESISTANCE AND SMOKE CONTROL TESTS FOR DOOR AND SHUTTER ASSEMBLIES, OPENABLE WINDOWS AND ELEMENTS OF BUILDING HARDWARE - PART 1: FIRE RESISTANCE TEST FOR DOOR AND SHUTTER ASSEMBLIES AND OPENABLE WINDOWS |
| 11/30253413 DC : 0 | BS EN 16361 - POWER OPERATED PEDESTRIAN DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PEDESTRIAN DOOR SETS, OTHER THAN SWING TYPE, INITIALLY DESIGNED FOR INSTALLATION WITH POWER OPERATION WITHOUT RESISTANCE TO FIRE AND SMOKE LEAKAGE CHARACTERISTICS |
| 14/30297827 DC : 0 | BS EN 14351-2 - WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 2: INTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND /OR SMOKE LEAKAGE CHARACTERISTICS |
| EN 16035:2012 | Hardware performance sheet (HPS) - Identification and summary of test evidence to facilitate the inter-changeability of building hardware for application to fire resisting and/or smoke control doorsets and/or openable windows |
| EN 1191:2012 | Windows and doors - Resistance to repeated opening and closing - Test method |
| UNE-EN 1191:2013 | Windows and doors - Resistance to repeated opening and closing - Test method |
| UNE-EN 1634-1:2016 | Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 1: Fire resistance test for door and shutter assemblies and openable windows |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.