PREN 54-10 : DRAFT 2012
Current
The latest, up-to-date edition.
FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 10: FLAME DETECTORS - POINT DETECTORS
12-01-2013
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Requirements
5 Tests and evaluation methods
6 Evaluation of conformity
Annex A (normative) - Apparatus for response point
determination
Annex B (informative) - Example of a methane burner
Annex C (normative) - Test fires
Annex D (normative) - Apparatus for dazzling test
Annex E (informative) - Apparatus for impact test
Annex ZA (informative) - Clauses of this European
Standard addressing the provisions of
the EU Construction Products Directive
(89/106/EEC)
Bibliography
Defines requirements, test methods and performance criteria for point-type, flame detectors that operate using radiation from a hydrocarbon flame for use in fire detection systems installed in and around buildings.
Committee |
TC 72
|
DocumentType |
Draft
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
12/30254902 DC : DRAFT JAN 2012 | Identical |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
ISO 209-1:1989 | Wrought aluminium and aluminium alloys Chemical composition and forms of products Part 1: Chemical composition |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
IEC 60064:1993+AMD1:2000+AMD2:2002+AMD3:2005 CSV | Tungsten filament lamps for domestic and similar general lighting purposes - Performance requirements |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
ISO 9001:2015 | Quality management systems — Requirements |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN 54-1:2011 | Fire detection and fire alarm systems - Part 1: Introduction |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.