PREN 54-28 : DRAFT 2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
FIRE DETECTION AND FIRE ALARM SYSTEM - PART 28: NON-RESETTABLE LINE-TYPE HEAT DETECTORS
01-02-2016
11-01-2016
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Product characteristics
5 Testing, assessment and sampling methods
6 Assessment and Verification of Constancy of
Performance (AVCP)
7 Classification and designation
8 Marking, labelling and packaging
Annex A (normative) - Mounting of the sensing element
of NLTHD in the heat tunnel
Annex B (normative) - Heat tunnel for response temperature
measurements
Annex C (informative) - Construction of the heat tunnel
Annex D (normative) - Test arrangement for vibration tests
for sensing element
Annex E (normative) - Test apparatus for impact test on the
sensing element
Annex ZA (informative) - Clauses of this European Standard
addressing the provisions of the EU Construction
Products Regulation
Bibliography
Pertains to non-resettable line-type heat detectors consisting of a sensing element using an electrical sensor cable which can be connected to a sensor control unit or either directly or through an interface module to a control and indicating equipment intended for use in fire detection and fire alarm systems installed in and around buildings and civil engineering works.
Committee |
TC 72
|
DocumentType |
Draft
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
15/30291072 DC : 0 | Identical |
11/30240441 DC : 0 | Identical |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
ISO 9001:2015 | Quality management systems — Requirements |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN 54-1:2011 | Fire detection and fire alarm systems - Part 1: Introduction |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.