PREN 54-29 : DRAFT 2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 29: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE AND HEAT SENSORS
01-04-2015
26-01-2015
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Test methods
Annex A (normative) - Smoke tunnel for
smoke response values
Annex B (normative) - Test aerosol for smoke
response value measurements
Annex C (normative) - Smoke measuring
instruments
Annex D (normative) - Heat tunnel for heat
response value
Annex E (normative) - Apparatus for dazzling test
Annex F (informative) - Apparatus for impact test
Annex G (normative) - Fire test room
Annex H (normative) - Open wood fire (TF1)
Annex I (normative) - Smouldering (pyrolysis)
wood fire (TF2)
Annex J (normative) - Glowing smouldering
cotton fire (TF3)
Annex K (normative) - Open plastics (polyurethane)
fire (TF4)
Annex L (normative) - Liquid (heptane) fire (TF5)
Annex M (normative) - Low temperature black smoke
(decalene) liquid fire (TF8)
Annex N (informative) - Information concerning the
construction of the smoke tunnel
Annex O (informative) - Construction of the heat tunnel
Annex P (informative) - Information concerning test
procedures and requirements for the response
to slowly developing fires
Annex Q (informative) - Information concerning the
construction of the measuring ionization chamber
Annex R (normative) - Additional requirements and
test methods for detectors with more than one
smoke sensor
Annex ZA (informative) - Clauses of this European
Standard addressing the provisions of the EU
Construction Products Directive (89/106/EEC)
Defines requirements, test methods and performance criteria for pointtype multi-sensor fire detectors for use in fire detection systems installed in buildings incorporating in one mechanical enclosure at least one optical or ionization smoke sensor and at least one heat sensor.
Committee |
TC 72
|
DocumentType |
Draft
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
09/30208451 DC : 0 | Identical |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
EN 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 54-5:2017 | Fire detection and fire alarm systems - Part 5: Heat detectors - Point heat detectors |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
ISO 9001:2015 | Quality management systems — Requirements |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN 54-1:2011 | Fire detection and fire alarm systems - Part 1: Introduction |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.