• Shopping Cart
    There are no items in your cart

SN EN 60601-2-25 : 1995 AMD 1 1999

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

MEDICAL ELECTRICAL EQUIPMENT - PART 2: PARTICULAR REQUIREMENTS FOR THE SAFETY OF ELECTROCARDIOGRAPHS

Withdrawn date

15-09-2018

Superseded by

SN EN 60601-2-25:2015

Published date

12-01-2013

Sorry this product is not available in your region.

Committees responsible
National foreword
Foreword
Section 1. General
1 Scope and object
2 Terminology and definitions
4 General requirements for tests
5 Classification
6 Identification, marking and documents
Section 2. Environmental conditions
10 Environmental conditions
Section 3. Protection against electric shock hazards
17 Separation
19 Continuous LEAKAGE CURRENTS and PATIENT AUXILIARY
    CURRENTS
20 Dielectric strength
Section 4. Protection against mechanical hazards
Section 5. Protection against hazards from unwanted or
            excessive radiation
34 Ultraviolet radiation
Section 6. Protection against hazards of ignition of
            flammable anaesthetic mixtures
36 Electromagnetic compatability
Section 7. Protection against excessive temperatures and
            other safety hazards
42 Excessive temperatures
44 Overflow, spillage, leakage, humidity, ingress of
    liquids, cleaning, sterilization disinfection and
    compatibility
Section 8. Accuracy of operating data and protection
            against hazardous output
51 Protection against hazardous output
Section 9. Abnormal operation and fault conditions;
            environmental tests
Section 10. Constructional requirements
56 Components and general assembly
57 MAIN PARTS, components and layout
Appendix L
Annex AA (informative) General guidance and rationale
Annex ZAA (informative) A-deviations
Annex ZA (normative) Normative references to international
                     publications with their corresponding
                     European publications
Figure 104 - Test of protection against the effects of
             defibrillation
Figure 105 - Test of protection against the effects of
             defibrillation
Figure 106 - Arrangements for ECG ELECTRODES on sponges
Figure 107 - Test of the recovery time from the effects
             on cardiac defibrillator discharge
             on cardiac defibrillator discharge
Figure 108 - Set-up for radiated and conducted emission
             test according to 36.201.1
Figure 109 - Set-up for radiated immunity test according
             to 36.202.2
Figure 110 - Test circuit for HF surgery interference
             measurement according to 36.202.101
Figure 111 - Test circuit for HF surgery interference
             measurement according to 36.202.101
Table 102 - Test conditions: Protection against the effect
             of defibrillation

Establishes particular requirements for the safety of electrocardiographs. Includes sections on: Environmental Conditions; Protection against Electric Shock Hazards; Protection against Mechanical Hazards; Constructional Requirements. Also includes detailed diagrams.

DocumentType
Standard
PublisherName
Swiss Standards
Status
Withdrawn
SupersededBy

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.