SN EN 60601-2-25 : 1995 AMD 1 1999
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
MEDICAL ELECTRICAL EQUIPMENT - PART 2: PARTICULAR REQUIREMENTS FOR THE SAFETY OF ELECTROCARDIOGRAPHS
15-09-2018
12-01-2013
Committees responsible
National foreword
Foreword
Section 1. General
1 Scope and object
2 Terminology and definitions
4 General requirements for tests
5 Classification
6 Identification, marking and documents
Section 2. Environmental conditions
10 Environmental conditions
Section 3. Protection against electric shock hazards
17 Separation
19 Continuous LEAKAGE CURRENTS and PATIENT AUXILIARY
CURRENTS
20 Dielectric strength
Section 4. Protection against mechanical hazards
Section 5. Protection against hazards from unwanted or
excessive radiation
34 Ultraviolet radiation
Section 6. Protection against hazards of ignition of
flammable anaesthetic mixtures
36 Electromagnetic compatability
Section 7. Protection against excessive temperatures and
other safety hazards
42 Excessive temperatures
44 Overflow, spillage, leakage, humidity, ingress of
liquids, cleaning, sterilization disinfection and
compatibility
Section 8. Accuracy of operating data and protection
against hazardous output
51 Protection against hazardous output
Section 9. Abnormal operation and fault conditions;
environmental tests
Section 10. Constructional requirements
56 Components and general assembly
57 MAIN PARTS, components and layout
Appendix L
Annex AA (informative) General guidance and rationale
Annex ZAA (informative) A-deviations
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Figure 104 - Test of protection against the effects of
defibrillation
Figure 105 - Test of protection against the effects of
defibrillation
Figure 106 - Arrangements for ECG ELECTRODES on sponges
Figure 107 - Test of the recovery time from the effects
on cardiac defibrillator discharge
on cardiac defibrillator discharge
Figure 108 - Set-up for radiated and conducted emission
test according to 36.201.1
Figure 109 - Set-up for radiated immunity test according
to 36.202.2
Figure 110 - Test circuit for HF surgery interference
measurement according to 36.202.101
Figure 111 - Test circuit for HF surgery interference
measurement according to 36.202.101
Table 102 - Test conditions: Protection against the effect
of defibrillation
Establishes particular requirements for the safety of electrocardiographs. Includes sections on: Environmental Conditions; Protection against Electric Shock Hazards; Protection against Mechanical Hazards; Constructional Requirements. Also includes detailed diagrams.
DocumentType |
Standard
|
PublisherName |
Swiss Standards
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
BS EN 60601-2-25:2015 | Identical |
NF EN 60601-2-25 : 1996 AMD 1 2005 | Identical |
IEC 60601-2-25:2011 | Identical |
EN 60601-2-25:2015 | Identical |
DIN EN 60601-2-25 : 2016 | Identical |
I.S. EN 60601-2-25:2015 | Identical |
UNE-EN 60601-2-25:2016 | Identical |