• Shopping Cart
    There are no items in your cart

TR 102 273-5 : 1.2.1

Current

Current

The latest, up-to-date edition.

ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); IMPROVEMENT ON RADIATED METHODS OF MEASUREMENT (USING TEST SITE) AND EVALUATION OF THE CORRESPONDING MEASUREMENT UNCERTAINTIES; PART 5: STRIPLINES

Available format(s)

Hardcopy , PDF

Language(s)

English

€17.53
Excluding VAT

Intellectual Property Rights
Foreword
1 Scope
2 References
3 Definitions, symbols and abbreviations
  3.1 Definitions
  3.2 Symbols
  3.3 Abbreviations
4 Introduction
  4.1 Open two-plate Stripline test cells
  4.2 Open three-plate Stripline test cells
  4.3 Closed Stripline cell
5 Uncertainty contributions specific to Stripline test
  facilities
  5.1 Mutual coupling
  5.2 Characteristic impedance of the Stripline
  5.3 Non-planar nature of the field distribution
  5.4 Field strength measurement
  5.5 Correction factor for the size of the EUT
  5.6 Influence of site effects
  5.7 General discussion
6 Verification procedure for a Stripline
  6.1 Definition
  6.2 Overview of the verification procedure
      6.2.1 Apparatus required
      6.2.2 Site preparation
      6.2.3 Measurement configuration
      6.2.4 What to record
  6.3 Verification procedure
  6.4 Processing the results of the verification procedure
      6.4.1 Introduction
      6.4.2 Completing the results sheet
  6.5 Report Format
  6.6 Calculation of measurement uncertainty
      6.6.1 Uncertainty contribution: Stage 1: Reference,
            direct attenuation measurement
      6.6.2 Uncertainty contribution: Stage 2: Stripline
            attenuation measurement
      6.6.3 Expanded uncertainty of the verification
            procedure
7 Test methods
  7.1 Introduction
      7.1.1 Site preparation
      7.1.2 Preparation of the EUT
      7.1.3 Power supplies to the EUT
  7.2 Transmitter tests
      7.2.1 Frequency error
      7.2.2 Effective radiated power
      7.2.3 Spurious emissions
      7.2.4 Adjacent channel power
  7.3 Receiver tests
      7.3.1 Sensitivity tests (30 MHz to 1 000 MHz)
            7.3.1.1 Apparatus required
            7.3.1.2 Method of measurement
            7.3.1.3 Procedure for the completion of the
                    results sheets
            7.3.1.4 Log book entries
            7.3.1.5 Statement of results
      7.3.2 Measurement uncertainty for Receiver sensitivity
            7.3.2.1 Uncertainty contributions: Stage 1:
                    EUT measurement
            7.3.2.2 Uncertainty contributions: Stage 2:
                    Field measurement
            7.3.2.3 Expanded uncertainty for the Receiver
                    sensitivity measurement
      7.3.3 Co-channel rejection
      7.3.4 Adjacent channel selectivity
      7.3.5 Intermodulation immunity
      7.3.6 Blocking immunity or desensitization
      7.3.7 Spurious response rejection
Annex A: Bibliography
History

Gives background to the subject of measurement uncertainty and proposes extensions and improvements relevant to radiated measurements.

Committee
ERM RP02
DocumentType
Standard
Pages
47
PublisherName
European Telecommunications Standards Institute
Status
Current

TS 103 051 : 1.1.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); EXPANDED MEASUREMENT UNCERTAINTY FOR THE MEASUREMENT OF RADIATED ELECTROMAGNETIC FIELDS
EN 61000-4-20:2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-20: TESTING AND MEASUREMENT TECHNIQUES - EMISSION AND IMMUNITY TESTING IN TRANSVERSE ELECTROMAGNETIC (TEM) WAVEGUIDES
CEI EN 61000-4-20 : 2013 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-20: TESTING AND MEASUREMENT TECHNIQUES - EMISSION AND IMMUNITY TESTING IN TRANSVERSE ELECTROMAGNETIC (TEM) WAVEGUIDES
TR 102 215 : 1.3.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); RECOMMENDED APPROACH, AND POSSIBLE LIMITS FOR MEASUREMENT UNCERTAINTY FOR THE MEASUREMENT OF RADIATED ELECTROMAGNETIC FIELDS ABOVE 1 GHZ
EG 202 290 : 1.1.1 FINAL DRAFT ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); MEASUREMENT UNCERTAINTIES AND TEST METHODOLOGIES FROM 1 GHZ TO 40 GHZ
BS EN 61000-4-20:2003 Electromagnetic Compatibility (EMC) Testing and measurement techniques. Emission and immunity testing in transverse electromagnetic (TEM) waveguides
TR 102 273-1-1 : 1.2.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); IMPROVEMENT ON RADIATED METHODS OF MEASUREMENT (USING TEST SITE) AND EVALUATION OF THE CORRESPONDING MEASUREMENT UNCERTAINTIES; PART 1: UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS; SUB-PART 1: INTRODUCTION
I.S. EN 61000-4-20:2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-20: TESTING AND MEASUREMENT TECHNIQUES - EMISSION AND IMMUNITY TESTING IN TRANSVERSE ELECTROMAGNETIC (TEM) WAVEGUIDES
UNE-EN 61000-4-20:2011 Electromagnetic compatibility (EMC) -- Part 4-20: Testing and measurement techniques - Emission and immunity testing in Transverse Electromagnetic (TEM) waveguides - Basic EMC publication
IEC 61000-4-20:2010 Electromagnetic compatibility (EMC) - Part 4-20: Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguides

TR 102 273-1-2 : 1.2.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); IMPROVEMENT ON RADIATED METHODS OF MEASUREMENT (USING TEST SITE) AND EVALUATION OF THE CORRESPONDING MEASUREMENT UNCERTAINTIES; PART 1: UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS; SUB-PART 2: EXAMPLES AND ANNEXES
TR 100 028-1 : 1.4.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS PART 1
EN 55020:2007/A12:2016 SOUND AND TELEVISION BROADCAST RECEIVERS AND ASSOCIATED EQUIPMENT - IMMUNITY CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 20:2006)
TR 102 273-1-1 : 1.2.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); IMPROVEMENT ON RADIATED METHODS OF MEASUREMENT (USING TEST SITE) AND EVALUATION OF THE CORRESPONDING MEASUREMENT UNCERTAINTIES; PART 1: UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS; SUB-PART 1: INTRODUCTION
TR 100 027 : 1.2.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); METHODS OF MEASUREMENT FOR PRIVATE MOBILE RADIO EQUIPMENT
TR 100 028-2 : 1.4.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS PART 2

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.