• Shopping Cart
    There are no items in your cart

TR 102 273-7 : 1.2.1

Current

Current

The latest, up-to-date edition.

ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); IMPROVEMENT ON RADIATED METHODS OF MEASUREMENT (USING TEST SITE) AND EVALUATION OF THE CORRESPONDING MEASUREMENT UNCERTAINTIES; PART 7: ARTIFICIAL HUMAN BEINGS

Available format(s)

Hardcopy , PDF

Language(s)

English

€46.74
Excluding VAT

Intellectual Property Rights
Foreword
1 Scope
2 References
3 Definitions, symbols and abbreviations
  3.1 Definitions
  3.2 Symbols
  3.3 Abbreviations
4 Introduction
  4.1 Artificial Human Beings
      4.1.1 Saltwater column
      4.1.2 Salty man
      4.1.3 "Salty-lite"
      4.1.4 Other salties
  4.2 Simulation of the human form
  4.3 Test conditions
5 Uncertainty contributions specific to Salty man/Salty-lite
  5.1 Comparison between average humans and Salties
  5.2 Uncertainties associated with the use of Salty man and
      Salty-lite
  5.3 Measurement considerations for Salty man and Salty-lite
      5.3.1 Frequency ranges
      5.3.2 Uncertainties of use
      5.3.3 Conclusion
6 Verification procedure for the Salty man and Salty-lite
  6.1 Definition
  6.2 Overview of the verification procedure
      6.2.1 Apparatus required
      6.2.2 Site preparation
      6.2.3 Measurement configuration
      6.2.4 What to record
  6.3 Verification procedure
  6.4 Processing the results of the verification procedure
      6.4.1 Report format
  6.5 Calculation of measurement uncertainty
      6.5.1 Introduction
      6.5.2 Discussion of uncertainty contributions
      6.5.3 Uncertainty contribution, actual measurement
7 Test methods
  7.1 Introduction
      7.1.1 Site preparation
      7.1.2 Preparation of the EUT
      7.1.3 Standard antennas
      7.1.4 Mutual coupling and mismatch loss correction
            factors
      7.1.5 Power supplies to the EUT
      7.1.6 Restrictions
  7.2 Transmitter tests
      7.2.1 Frequency error
      7.2.2 Effective radiated power
      7.2.3 Spurious emissions
      7.2.4 Adjacent channel power
  7.3 Receiver tests
      7.3.1 Sensitivity tests in an Anechoic Chamber
             (30 MHz to 1 000 MHz)
             7.3.1.1 Apparatus required
             7.3.1.2 Method of measurement
             7.3.1.3 Procedure for completing the results
                     sheets
             7.3.1.4 Log book entries
             7.3.1.5 Statement of results
      7.3.2 Measurement uncertainty for Receiver Sensitivity
             (Anechoic Chamber)
             7.3.2.1 Uncertainty contributions: Stage 1:
                     Determination of transform factor
             7.3.2.2 Uncertainty contributions: Stage 2:
                     EUT measurement
             7.3.2.3 Expanded uncertainty of the receiver
                     sensitivity measurement
      7.3.3 Sensitivity tests in an Anechoic Chamber with a
             Ground Plane (30 MHz to 1 000 MHz)
             7.3.3.1 Apparatus required
             7.3.3.2 Method of measurement
             7.3.3.3 Procedure for completion of the results
                     sheets
             7.3.3.4 Log book entries
             7.3.3.5 Statement of results
      7.3.4 Measurement uncertainty for Receiver Sensitivity
             7.3.4.1 Uncertainty contributions: Stage 1:
                     Determination of transform factor
             7.3.4.2 Uncertainty contributions: Stage 2:
                     EUT measurement
             7.3.4.3 Expanded uncertainty of the receiver
                     sensitivity measurement
      7.3.5 Sensitivity tests (Open Area Test Site)
             (30 to 1 000 MHz)
             7.3.5.1 Apparatus required
             7.3.5.2 Method of measurement
             7.3.5.3 Procedure for completion of the results
                     sheets
             7.3.5.4 Log book entries
             7.3.5.5 Statement of results
      7.3.6 Measurement uncertainty for Receiver Sensitivity
             7.3.6.1 Uncertainty contributions: Stage 1:
                     Determination of transform factor
             7.3.6.2 Uncertainty contributions: Stage 2:
                     EUT measurement
             7.3.6.3 Expanded uncertainty of the receiver
                     sensitivity measurement
      7.3.7 Co-channel rejection
      7.3.8 Adjacent channel selectivity
      7.3.9 Intermodulation immunity
      7.3.10 Blocking immunity or desensitization
      7.3.11 Spurious response rejection
Annex A: Bibliography
History

Gives background to the subject of measurement uncertainty and proposes extensions and improvements relevant to radiated measurements.

Committee
ERM RP02
DocumentType
Standard
Pages
69
PublisherName
European Telecommunications Standards Institute
Status
Current

TS 103 051 : 1.1.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); EXPANDED MEASUREMENT UNCERTAINTY FOR THE MEASUREMENT OF RADIATED ELECTROMAGNETIC FIELDS
TR 102 215 : 1.3.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); RECOMMENDED APPROACH, AND POSSIBLE LIMITS FOR MEASUREMENT UNCERTAINTY FOR THE MEASUREMENT OF RADIATED ELECTROMAGNETIC FIELDS ABOVE 1 GHZ
EG 202 290 : 1.1.1 FINAL DRAFT ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); MEASUREMENT UNCERTAINTIES AND TEST METHODOLOGIES FROM 1 GHZ TO 40 GHZ

TR 102 273-1-2 : 1.2.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); IMPROVEMENT ON RADIATED METHODS OF MEASUREMENT (USING TEST SITE) AND EVALUATION OF THE CORRESPONDING MEASUREMENT UNCERTAINTIES; PART 1: UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS; SUB-PART 2: EXAMPLES AND ANNEXES
TR 100 028-1 : 1.4.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS PART 1
TR 102 273-1-1 : 1.2.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); IMPROVEMENT ON RADIATED METHODS OF MEASUREMENT (USING TEST SITE) AND EVALUATION OF THE CORRESPONDING MEASUREMENT UNCERTAINTIES; PART 1: UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS; SUB-PART 1: INTRODUCTION
IEC 60489-6:1999 Radio equipment used in mobile services - Methods of measurement - Part 6: Data equipment
ANSI C63.5 : 2006 ELECTROMAGNETIC COMPATIBILITY - RADIATED EMISSION MEASUREMENTS IN ELECTROMAGNETIC INTERFERENCE (EMI) CONTROL - CALIBRATION AND QUALIFICATION OF ANTENNAS (9 KHZ TO 40 GHZ)
TR 100 027 : 1.2.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); METHODS OF MEASUREMENT FOR PRIVATE MOBILE RADIO EQUIPMENT
TR 100 028-2 : 1.4.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS PART 2

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.