• Shopping Cart
    There are no items in your cart

TR 102 457 : 1.1.1

Current

Current

The latest, up-to-date edition.

TRANSMISSION AND MULTIPLEXING (TM); STUDY ON THE ELECTROMAGNETIC RADIATED FIELD IN FIXED RADIO SYSTEMS FOR ENVIRONMENTAL ISSUES

Available format(s)

Hardcopy , PDF

Language(s)

English

€46.74
Excluding VAT

Intellectual Property Rights
Foreword
1 Scope
2 References
3 Definitions, symbols and abbreviations
  3.1 Definitions
  3.2 Symbols
  3.3 Abbreviations
4 Some properties of fixed radio systems
  4.1 General
  4.2 Point-to-point communication systems
  4.3 Multipoint communication systems
5 Antenna properties
  5.1 Near-field - Far-field concept
  5.2 Emission parameters
  5.3 Parameter description
  5.4 Relationship between parameters (V/m, W/m[2])
  5.5 Variation with distance and power
6 Exposure limits
  6.1 General public exposure
  6.2 Occupational exposure
7 Calculations and measurements of power density
  7.1 General
  7.2 Far-field power density
  7.3 Near-field power density
  7.4 Power density upper bound
8 Assessment of compliance to limits
  8.1 General
  8.2 Compliance boundaries evaluation
  8.3 Tabulated values
Annex A: Power density calculations
      A.1 Near-field calculations using the Fresnel
          transform
Annex B: Simulations and measurements
      B.1 Simulations and measurements of a 0,24 m 38 GHz
          antenna
      B.2 Simulations and measurements of a 0,6 m 8,1 GHz
          antenna
      B.3 RFS investigation on antennas from 5 to 38 GHz
      B.4 Simulations using SRSR tool on 8 GHz and 13 GHz
          antennas
History

Specifies guidelines on how to evaluate the electromagnetic fields in the main beam of fixed radio system (Point to Point/Point to Multipoint/Multipoint to Multipoint) using circular parabolic antennas for compliance assessment with human exposure limits.

Committee
TM 04 4
DocumentType
Standard
Pages
53
PublisherName
European Telecommunications Standards Institute
Status
Current

BS IEC 62232:2011 Determination of RF field strength and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure
EN 62232:2017 Determination of RF field strength, power density and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure
BS EN 62232:2017 Determination of RF field strength, power density and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure (IEC 62232:2017)
IEC 62232:2017 Determination of RF field strength, power density and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure
I.S. EN 62232:2017 DETERMINATION OF RF FIELD STRENGTH, POWER DENSITY AND SAR IN THE VICINITY OF RADIOCOMMUNICATION BASE STATIONS FOR THE PURPOSE OF EVALUATING HUMAN EXPOSURE

EG 202 373 : 1.1.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); GUIDE TO THE METHODS OF MEASUREMENT OF RADIO FREQUENCY (RF) FIELDS
TR 102 243-1 : 1.2.1 FIXED RADIO SYSTEMS; REPRESENTATIVE VALUES FOR TRANSMITTER POWER AND ANTENNA GAIN TO SUPPORT INTER- AND INTRA-COMPATIBILITY AND SHARING ANALYSIS; PART 1: DIGITAL POINT-TO-POINT SYSTEMS
EN 302 217-1 : 2.1.1 FIXED RADIO SYSTEMS; CHARACTERISTICS AND REQUIREMENTS FOR POINT-TO-POINT EQUIPMENT AND ANTENNAS; PART 1: OVERVIEW, COMMON CHARACTERISTICS AND SYSTEM-INDEPENDENT REQUIREMENTS
EN 50383 : 2010 COR 2013 BASIC STANDARD FOR THE CALCULATION AND MEASUREMENT OF ELECTROMAGNETIC FIELD STRENGTH AND SAR RELATED TO HUMAN EXPOSURE FROM RADIO BASE STATIONS AND FIXED TERMINAL STATIONS FOR WIRELESS TELECOMMUNICATION SYSTEMS (110 MHZ - 40 GHZ)
119999/5/EC : 1999 DIRECTIVE 1999/5/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 9 MARCH 1999 ON RADIO EQUIPMENT AND TELECOMMUNICATIONS TERMINAL EQUIPMENT AND THE MUTUAL RECOGNITION OF THEIR CONFORMITY

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.