UFC 4-024-01 : 2008
Current
The latest, up-to-date edition.
UNIFIED FACILITIES CRITERIA - SECURITY ENGINEERING: PROCEDURES FOR DESIGNING AIRBORNE CHEMICAL, BIOLOGICAL, AND RADIOLOGICAL PROTECTION FOR BUILDINGS
26-09-2016
CHAPTER 1 - INTRODUCTION
CHAPTER 2 - ASSUMPTIONS AND DESIGN CONSTRAINTS
CHAPTER 3 - TECHNICAL REQUIREMENTS AND GUIDANCE
CHAPTER 4 - STARTUP, OPERATION, AND MAINTENANCE OF THE COLPRO SYSTEM
APPENDIX A - REFERENCES
APPENDIX B - GLOSSARY
APPENDIX C - AIRLOCKS AND ENTRY OR EXIT PROCESSING
APPENDIX D - SHELTERING IN PLACE
APPENDIX E - PROTECTIVE ACTION PLAN: OPERATIONAL PROCEDURES TO PROTECT EXISTING BUILDINGS AND THEIR OCCUPANTS FROM AIRBORNE HAZARDS
APPENDIX F - DETERMINING THE BUILDING PROTECTION FACTOR
APPENDIX G - COLPRO FILTRATION SYSTEM EQUIPMENT
APPENDIX H - COLPRO FILTRATION SYSTEM TESTING REQUIREMENTS
Gives design guidance to protect assets against airborne delivery tactics using CBR agents. Covers minimum requirements, recommended protective measures for all buildings, filtration system types and arrangements, protective area overpressure, and ColPro system design and equipment.
DocumentType |
Standard
|
PublisherName |
US Military Specs/Standards/Handbooks
|
Status |
Current
|
Supersedes |
NFPA 1221 : 2016 | INSTALLATION, MAINTENANCE, AND USE OF EMERGENCY SERVICES COMMUNICATIONS SYSTEMS |
UFC 4-023-10 : 2016 | UNIFIED FACILITIES CRITERIA - SAFE HAVENS |
UFC 4-020-01 : 2008 | UNIFIED FACILITIES CRITERIA - DOD SECURITY ENGINEERING FACILITIES PLANNING MANUAL |
UFC 4-010-01 : 2018 | UNIFIED FACILITIES CRITERIA - DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS |
ASHRAE 52.2 : 2017 | METHOD OF TESTING GENERAL VENTILATION AIR-CLEANING DEVICES FOR REMOVAL EFFICIENCY BY PARTICLE SIZE |
ASME N510 : 2007 | TESTING OF NUCLEAR AIR-TREATMENT SYSTEMS |
NFPA 101 : 2018 | LIFE SAFETY CODE |
MIL-PRF-51525 Revision B:2004 | FILTER, GAS, 200 CFM |
ASME AG 1 : 2012 | CODE ON NUCLEAR AIR AND GAS TREATMENT |
UFC 3-400-02 : 2003 | UNIFIED FACILITIES CRITERIA - DESIGN: ENGINEERING WEATHER DATA |
ASHRAE HDBK FUNDAMENTALS : 2013 | ASHRAE HANDBOOK - FUNDAMENTALS |
UFC 3-340-01 : 2002 | UNIFIED FACILITIES CRITERIA - DESIGN AND ANALYSIS OF HARDENED STRUCTURES TO CONVENTIONAL WEAPONS EFFECTS (FOUO) |
MIL-DTL-32101 Base Document:2002 | CARBON, ACTIVATED, IMPREGNATED, COPPER-SILVER-ZINC-MOLYBDENUM-TRIETHYLENEDIAMINE (ASZM-TEDA) |
ASHRAE 62.1 : 2016 | VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY |
MIL-PRF-32016 Revision A:2002 | CELL, GAS PHASE, ADSORBER |
UL 586:9ED 2009-08-14 | High-Efficiency, Particulate, Air Filter Units |
ASME NQA 1 : 2015 | Quality Assurance Requirements for Nuclear Facility Applications (NQA-1 - 2015) |
UFC 4-010-02 : 2012 | UNIFIED FACILITIES CRITERIA - DOD MINIMUM ANTITERRORISM STANDOFF DISTANCES FOR BUILDINGS (FOUO) |
MIL-PRF-51526 Revision B:2004 | Filter, Particulate, 200 CFM |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.