• There are no items in your cart

UL 1484:5ED 2016-04-20

Current

Current

The latest, up-to-date edition.

Residential Gas Detectors

Available format(s)

Hardcopy

Published date

20-04-2016

€965.88
Excluding VAT

FOREWORD
INTRODUCTION
1 Scope
2 General
3 Glossary
4 Detector reliability prediction
5 Installation and operating instructions
CONSTRUCTION
Assembly
6 Product assembly
7 Detection-threshold adjustment
8 Supplementary signaling feature
9 Sharp edges
10 Enclosures
11 Protection against corrosion
Field-wiring connections
12 General
13 Cord-connected products
14 Permanently connected products
15 Supplementary signaling circuits
16 Grounding
Internal wiring
17 General
18 Wiring methods
19 Separation of circuits
20 Bonding for grounding
Electrical components
21 General
22 Lampholders and lamps
23 Printed wiring-boards
24 Protective devices
25 Switches
26 Transformers
Spacings
27 General
PERFORMANCE
General
28 Samples and data for test
29 Test voltages
Tests
30 Normal operation test
31 Input-measurement test
32 Electrical-supervision test
33 Temperature test
34 Dielectric voltage-withstand test
35 Abnormal-operation test
36 Overload test
37 Endurance test
38 Audibility test
39 Leakage current test
40 Tests of thermoplastic materials
41 Power supply tests
42 Ignition test
43 Detection threshold tests
44 Permanence of marking tests
45 Strain-relief test
MANUFACTURING AND PRODUCTION TESTS
46 General
47 Production-line detection-threshold calibration
     tests
48 Production-line dielectric voltage-withstand test
49 Production-line grounding continuity tests
MARKING
50 General
INSTRUCTIONS
51 General
SUPPLEMENT SA
SA1 Instructions for determining a reliability
     prediction for gas detectors
SA2 Methods for determining failure rate
SA3 Maximum detector failure rates
CRITERIA FOR ACCEPTANCE OF MICROELECTRONIC DEVICES
SA4 General
SA5 Quality-assurance-screening program
SA6 Determination of the failure rate number
     supplemented by burn-in test
APPENDIX
A Standards for components

These requirements cover electrically operated gas detectors intended for installation in residential occupancies and recreational vehicles (RVs).

DevelopmentNote
NEW CHILD REV 3 2022 IS NOW ADDED
DocumentType
Standard
Pages
0
ProductNote
NEW CHILD REV 3 2022 IS NOW ADDED
PublisherName
Underwriters Laboratories
Status
Current

NFPA 96:2024 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations
NFPA 96 : 2017 VENTILATION CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING OPERATIONS
NFPA 1192 : 2018 RECREATIONAL VEHICLES
UL 2075:2ED 2013-03-05 Gas and Vapor Detectors and Sensors
CSA Z240 RV SERIES : 2014 RECREATIONAL VEHICLES
CSA Z240 VC SERIES : 2014
08/30190078 DC : DRAFT SEP 2008 BS ISO 26142 - HYDROGEN DETECTOR
ASHRAE HDBK REFRIGERATION : 2014 ASHRAE HANDBOOK - REFRIGERATION

UL 1439:5ED 2015-04-21 Tests for Sharpness of Edges on Equipment
UL 4248-11:1ED 2007-02-28 Fuseholders - Part 11: Type C (Edison Base) and Type S Plug Fuse
UL 4248-9:1ED 2007-02-28 Fuseholders - Part 9: Class K
UL 746A:6ED 2012-09-06 Polymeric Materials - Short Term Property Evaluations
UL 4248-15:1ED 2007-02-28 Fuseholders - Part 15: Class T
UL 4248-4:1ED 2007-02 Fuseholders - Part 4: Class CC
UL 496:14ED 2017-09-05 Lampholders

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.