UNE-EN 14792:2017
Current
The latest, up-to-date edition.
Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: chemiluminescence
Hardcopy , PDF
Spanish, Castilian, English
13-09-2017
This European Standard specifies the standard reference method (SRM) based on the chemiluminescence principle for the determination of the nitrogen oxides (NOx) in flue gases emitted to the atmosphere from ducts and stacks. It includes the sampling and the gas conditioning system, as well as the analyser. This European Standard specifies the characteristics to be determined and the performance criteria to be fulfilled by measuring systems based on this measurement method. It applies for periodic monitoring and for the calibration or control of automatic measuring systems (AMS) permanently installed on a stack, for regulatory or other purposes. This European Standard specifies criteria for demonstration of equivalence of an alternative method to the SRM by application of prEN 14793.This European standard has been validated during field tests on waste incineration, co-incineration and large combustion installations and on a recognized test-bench. It has been validated for sampling periods of 30 min in the range of 0 mg/m3 to 1 300 mg/m3 of NO2 for large combustion plants and 0 mg/m3 to 400 mg/m3 of NO2 for waste incineration, according to emission limit values (ELV) laid down in the Directive 2010/75/EC.The ELV for NOx (NO + NO2) in EU directives are expressed in mg/m3 of NO2 on a dry basis, at a specified value for oxygen and at reference conditions (273 K and 101,3 kPa).NOTE The characteristics of installations, the conditions during field tests and the values of repeatability and reproducibility in the field are given in Annex F.
| Committee |
CTN 77/SC 2
|
| DocumentType |
Standard
|
| Pages |
64
|
| PublisherName |
Asociación Española de Normalización
|
| Status |
Current
|
| Standards | Relationship |
| NF EN 14792 : 2017 | Identical |
| I.S. EN 14792:2017 | Identical |
| EN 14792:2017 | Identical |
| NBN EN 14792 : 2006 | Identical |
| DIN EN 14792:2006-04 | Identical |
| NS EN 14792 : 2017 | Identical |
| BS EN 14792:2005 | Identical |
| NEN EN 14792 : 2017 | Identical |
| ISO 5725-6:1994 | Accuracy (trueness and precision) of measurement methods and results — Part 6: Use in practice of accuracy values |
| EN 15259:2007 | Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report |
| ISO/IEC Guide 99:2007 | International vocabulary of metrology — Basic and general concepts and associated terms (VIM) |
| EN 13284-1:2017 | Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method |
| EN ISO 14956:2002 | Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty (ISO 14956:2002) |
| ISO 5725-2:1994 | Accuracy (trueness and precision) of measurement methods and results — Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method |
| EN 14790:2017 | Stationary source emissions - Determination of the water vapour in ducts - Standard reference method |
| EN 15267-4:2017 | Air quality - Certification of automated measuring systems - Part 4: Performance criteria and test procedures for automated measuring systems for periodic measurements of emissions from stationary sources |
| ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
| EN 14793:2017 | Stationary source emissions - Demonstration of equivalence of an alternative method with a reference method |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.