• UNI EN 1366-3 : 2009

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 3: PENETRATION SEALS

    Available format(s): 

    Superseded date:  05-08-2022

    Language(s): 

    Published date:  31-12-2008

    Publisher:  Ente Nazionale Italiano di Unificazione (UNI)

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Test equipment
    5 Test conditions
       5.1 Heating conditions
       5.2 Pressure conditions
    6 Test specimen
       6.1 Size and distances
       6.2 Number
       6.3 Design
       6.4 Construction
       6.5 Verification
    7 Installation of test specimen
       7.1 General
       7.2 Supporting construction
       7.3 Installation of service(s)
       7.4 Installation of penetration seal
       7.5 Multiple penetration seals in one test specimen
    8 Conditioning
    9 Application of instrumentation
       9.1 Thermocouples
       9.2 Integrity measurement
       9.3 Pressure
    10 Test procedure
       10.1 General
       10.2 Integrity
       10.3 Other observations
    11 Performance criteria
       11.1 Integrity
       11.2 Insulation
       11.3 Multiple penetrations
    12 Test report
    13 Field of direct application of test results
       13.1 Orientation
       13.2 Supporting construction
       13.3 Services
       13.4 Service support construction
       13.5 Seal size and distances
    Annex A (normative) - Standard configuration for large cable
            penetration seals
            A.1 Structure of specimens
            A.2 Non-standard configuration
            A.3 Field of direct application
    Annex B (normative) - Standard configuration for small cable
            penetration seals
            B.1 Structure of specimens
            B.2 Field of direct application
            B.3 Non-standard configuration
    Annex C (normative) - Standard configuration and field of direct
            application for modular systems and cable boxes
            C.1 Modular Systems
            C.2 Cable boxes
            C.3 Non-standard configuration
    Annex D (normative) - Specimen design and field of direct
            application for bus bars
            D.1 Structure of specimens
            D.2 Field of direct application
            D.3 Non-standard configuration
    Annex E (normative) - Standard configuration and field of direct
            application for pipe penetration seals
            E.1 Standard configuration for penetration seals for
                pipes according to 6.3.2 a) - "metal pipes"
            E.2 Standard configuration for penetration seals for
                pipes according to 6.3.2 d) - "plastic pipes"
            E.3 Trunking and conduits
            E.4 Standard configuration for floor penetrations ending
                at floor level (e.g. floor drain)
    Annex F (normative) - Standard configuration and field of direct
            application for large mixed penetration seals
            F.1 General
            F.2 Standard Mixed Module
            F.3 Standard configuration for combinations of
                type a) according to F.1.2
            F.4 Standard configuration for combinations of
                type b), c) and d) according to F.1.2
            F.5 Field of direct application
    Annex G (normative) - Critical pipe/cable approach
            G.1 General
            G.2 Definition of "critical"
            G.3 Procedure selecting critical pipes from previous
                test data
            G.4 Procedure selecting critical cables from previous
                test data
    Annex H (informative) - Explanatory notes
            H.1 General
            H.2 Notes on the scope and application of test results
            H.3 Notes on test conditions
            H.4 Notes on test construction
            H.5 Notes on test procedure
            H.6 Notes on test criteria
            H.7 Notes on validity of test results (field of
                application)
            H.8 Notes on test report
    Bibliography

    Abstract - (Show below) - (Hide below)

    Describes a method of test and criteria for the evaluation (including field of application rules) of the ability of a penetration seal to maintain the fire resistance of a separating element at the position at which it has been penetrated by a service.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Ente Nazionale Italiano di Unificazione (UNI)
    Status Superseded
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 520:2004+A1:2009 Gypsum plasterboards - Definitions, requirements and test methods
    EN 61386-21:2004/A11:2010 CONDUIT SYSTEMS FOR CABLE MANAGEMENT - PART 21: PARTICULAR REQUIREMENTS - RIGID CONDUIT SYSTEMS
    HD 21-3 : S3 AMD 2 2008 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - NON-SHEATHED CABLES FOR FIXED WIRING
    EN 1566-1:1998 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Chlorinated poly(vinyl chloride) (PVC-C) - Part 1: Specifications for pipes, fittings and the system
    EN 10305-6:2016 Steel tubes for precision applications - Technical delivery conditions - Part 6: Welded cold drawn tubes for hydraulic and pneumatic power systems
    IEC 60227-3:1993+AMD1:1997 CSV Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 3: Non-sheathed cables for fixed wiring
    IEC 61386-21:2002 Conduit systems for cable management - Part 21: Particular requirements - Rigid conduit systems
    EN 1453-1:2017/AC:2017 PLASTICS PIPING SYSTEMS WITH STRUCTURED-WALL PIPES FOR SOIL AND WASTE DISCHARGE (LOW AND HIGH TEMPERATURE) INSIDE BUILDINGS - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES AND THE SYSTEM
    ISO 13943:2017 Fire safety — Vocabulary
    EN 13501-2:2016 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
    HD 603 S1:1994/A3:2007 DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV
    HD 22-4 : 200S4 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 4: CORDS AND FLEXIBLE CABLES
    EN 12449:2016 Copper and copper alloys - Seamless, round tubes for general purposes
    EN 61386-1:2008 Conduit systems for cable management - Part 1: General requirements
    EN 10305-4:2016 Steel tubes for precision applications - Technical delivery conditions - Part 4: Seamless cold drawn tubes for hydraulic and pneumatic power systems
    EN 1455-1:1999 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Acrylonitrile-butadiene-styrene (ABS) - Part 1: Requirements for pipes, fittings and the system
    EN 13600:2013 Copper and copper alloys - Seamless copper tubes for electrical purposes
    EN 1992-1-2:2004/AC:2008 EUROCODE 2: DESIGN OF CONCRETE STRUCTURES - PART 1-2: GENERAL RULES - STRUCTURAL FIRE DESIGN
    EN 12666-1:2005+A1:2011 Plastics piping systems for non-pressure underground drainage and sewerage - Polyethylene (PE) - Part 1: Specifications for pipes, fittings and the system
    EN ISO 13943:2017 Fire safety - Vocabulary (ISO 13943:2017)
    EN 10025-2:2004/AC:2005 HOT ROLLED PRODUCTS OF STRUCTURAL STEELS - PART 2: TECHNICAL DELIVERY CONDITIONS FOR NON-ALLOY STRUCTURAL STEELS
    EN 12201-2:2011+A1:2013 Plastics piping systems for water supply, and for drainage and sewerage under pressure - Polyethylene (PE) - Part 2: Pipes
    EN 1363-1:2012 Fire resistance tests - Part 1: General Requirements
    EN 1519-1:1999 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Polyethylene (PE) - Part 1: Specifications for pipes, fittings and the system
    EN 1996-1-2:2005/AC:2010 EUROCODE 6 - DESIGN OF MASONRY STRUCTURES - PART 1-2: GENERAL RULES - STRUCTURAL FIRE DESIGN
    IEC 61386-1:2008+AMD1:2017 CSV Conduit systems for cable management - Part 1: General requirements
    EN 1452-1 : 1999 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: GENERAL
    EN 1363-2:1999 Fire resistance tests - Part 2: Alternative and additional procedures
    EN 1565-1:1998 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Styrene copolymer blends (SAN+PVC) - Part 1: Specifications for pipes, fittings and the system
    HD 604 S1:1994/A3:2005 0.6/1 KV POWER CABLES WITH SPECIAL FIRE PERFORMANCE FOR USE IN POWER STATIONS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations