EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 5: METAL SANDWICH PANEL CONSTRUCTION
06-10-2022
01-01-2009
Foreword
1 Scope
2 Normative references
3 Terms and definitions, symbols and abbreviations
3.1 Terms and definitions
3.2 Symbols and abbreviations
4 Establishing the field of extended application
4.1 General
4.2 Assumptions in the extended application
4.3 Assumed structural behaviour of a sandwich panel in
fire
5 Rules for extended applications of the tested product
5.1 General
5.2 Variations in the materials of the product
5.3 Variations in the construction
5.4 Interaction between the factor influences
5.5 Support structure
5.6 Heating conditions
6 Small scale tests and calculation methods
6.1 Small scale tests
6.2 Calculation methods
6.3 Additional measurements to be carried out in the
reference test
7 Report of the extended application analysis
Annex A (informative) - Typical behaviour of a metal faced
sandwich panel wall when exposed to fire
Annex B (normative) - Evaluation of extension of span length
Bibliography
Provides rules for extended applications, provides guidance, and, where appropriate, defines procedures, for variations of certain parameters and factors associated with the design of internal and external non-loadbearing walls constructed of metal sandwich panels and that have been tested in accordance with EN 1364-1.
DocumentType |
Standard
|
PublisherName |
Ente Nazionale Italiano di Unificazione (UNI)
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
EN 15254-5:2018 | Identical |
EN 14509:2013 | Self-supporting double skin metal faced insulating panels - Factory made products - Specifications |
EN 1364-1:1999 | Fire resistance tests for non-loadbearing elements - Part 1: Walls |
EN 13501-2:2016 | Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services |
EN 1363-1:2012 | Fire resistance tests - Part 1: General Requirements |
EN 1363-2:1999 | Fire resistance tests - Part 2: Alternative and additional procedures |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.