• Shopping Cart
    There are no items in your cart

VDE 0441-5 : 2002

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

COMPOSITE STRING INSULATOR UNITS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE GREATER THAN 1 KV - DIMENSIONAL AND ELECTRICAL CHARACTERISTICS

Superseded date

16-11-2022

Superseded by

VDE 0674-103-2:2019

Published date

12-01-2013

Sorry this product is not available in your region.

1 Anwendungsbereich
2 Normative Verweisungen
3 Mechanische Kenngrössen und Masse
4 Elektrische Kenngrössen
5 Bezeichnung
6 Kennzeichnung
7 Toleranzen
Anhang A (informativ) Information zum Kriechweg
Anhang ZA (normativ) Normative Verweisungen auf
          internationale Publikationen mit ihren
          entsprechenden europäischen Publikationen

Dieser Teil von IEC 61466 gilt für Verbund-Kettenisolatoren mit einer festgelegten mechanischen Kraft (SML) von 40 kN und 70 kN für Wechselstrom-Verteilungsfreileitungen mit einer Nennspannung über 1000 V und einer Frequenz bis 100 Hz. Er gilt auch für Isolatoren ähnlicher Konstruktion, die in Schaltanlagen oder für elektrische Fahrleitungen verwendet werden. Diese Norm gilt für Kettenisolatoren vom Verbundtyp mit Verbindungen nach IEC 61466-1. Diese Norm beschreibt festgelegte Werte für elektrische Kenngrössen und Masse von Verbund-Kettenisolatoren für Verteilungsfreileitungen mit einer höchsten Blitzstossspannung von 325 kV und einer festgelegten mechanischen Kraft (SML) von 40 kN und 70 kN. ANMERKUNG: Allgemeine Definitionen und Prüfverfahren sind in IEC 61109 angegeben.

DevelopmentNote
Supersedes VDE 0441-103 (02/2003) DRAFT AMD 2 issued in April 2016. (05/2016)
DocumentType
Standard
PublisherName
Verband Deutscher Elektrotechniker
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
EN 61466-2:1998/A1:2002 Identical
DIN EN 61466-2 : 2002 Identical
IEC 61466-2:1998+AMD1:2002 CSV Identical
DIN EN 61466-2 : 2002 Corresponds

DIN EN 61466-1 : 2017 COR 1 2017 COMPOSITE STRING INSULATOR UNITS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE GREATER THAN 1000 V - PART 1: STANDARD STRENGTH CLASSES AND END FITTINGS (IEC 61466-1:2016)
IEC 61466-1:2016 Composite string insulator units for overhead lines with a nominal voltage greater than 1 000 V - Part 1: Standard strength and end fittings
VDE 0441-4 : 1997 COR 1 2010 COMPOSITE STRING INSULATOR UNITS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE GREATER THAN 1 KV - STANDARD STRENGTH CLASSES AND END FITTINGS
VDE 0441-100 : 2009 INSULATORS FOR OVERHEAD LINES - COMPOSITE SUSPENSION AND TENSION INSULATORS FOR A.C. SYSTEMS WITH A NOMINAL VOLTAGE GREATER THAN 1 000 V DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
DIN VDE 0441-100 : DRAFT 1992 TESTS OF COMPOSITE INSULATORS FOR A.C. OVERHEAD LINES WITH A NOMINAL VOLTAGE GREATER THAN 1000 V
IEC 61109:2008 Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria
DIN EN 60071-1 : 2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
IEC 60071-2:1996 Insulation co-ordination - Part 2: Application guide
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
DIN EN 60071-2 : 1997 INSULATION CO-ORDINATION - PART 2: APPLICATION GUIDE

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.