VDE 0750-2-40 : 1998

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

MEDICAL ELECTRICAL EQUIPMENT - PART 2-40: PARTICULAR REQUIREMENTS FOR THE SAFETY OF ELECTROMYOGRAPHS AND EVOKED RESPONSE EQUIPMENT

Superseded date

14-11-2022

Superseded by

VDE 0750-2-40:2019-04

Published date

12-01-2013

Sorry this product is not available in your region.

Einführung
HAUPTABSCHNITT EINS - ALLGEMEINES
1 Anwendungsbereich und Zweck
2 Begriffe und Definitionen
5 Klassifikation
6 Bezeichnungen, Aufschriften und Begleitpapiere
7 Strom- bzw. Leistungsaufnahme
HAUPTABSCHNITT ZWEI - UMWELTBEDINGUNGEN
HAUPTABSCHNITT DREI - SCHUTZ GEGEN DIE GEFAHR EINES
ELEKTRISCHEN SCHLAGES
14 Anforderungen in bezug auf die Einteilung der
   Geräte
20 Spannungsfestigkeit
HAUPTABSCHNITT VIER - SCHUTZ GEGEN MECHANISCHE GEFÄHRDUNG
HAUPTABSCHNITT FÜNF - SCHUTZ GEGEN GEFAHREN DURCH
UNERWÜNSCHTE ODER ÜBERMÄSSIGE STRAHLUNG
36 Elektromagnetische Verträglichkeit
HAUPTABSCHNITT SECHS - SCHUTZ GEGEN GEFAHREN DURCH ZÜNDUNG
BRENNBARER GEMISCHE
HAUPTABSCHNITT SIEBEN - SCHUTZ GEGEN ÜBERMÄSSIGE TEMPERATUREN
UND ANDERE GEFÄHRDUNGEN
42 Übermässige Temperaturen
46 Menschliches Versagen
HAUPTABSCHNITT ACHT - GENAUIGKEIT DER BETRIEBSDATEN UND
SCHUTZ GEGEN GEFÄHRDENDE AUSGANGSWERTE
50 Genauigkeit der Betriebsdaten
51 Schutz gegen gefährdende Ausgangswerte
HAUPTABSCHNITT NEUN - NICHT BESTIMMUNGSGEMÄSSER BETRIEB UND
FEHLERFÄLLE; UMWELTPRÜFUNGEN
HAUPTABSCHNITT ZEHN - KONSTRUKTIVE ANFORDERUNGEN
Anhang AA (informativ) Allgemeine Erklärung und
          Begründung
Anhang ZA (normativ) Normative Verweisungen
          auf Internationale Publikationen mit ihren
          entsprechenden Europäischen Publikationen
Anhang ZB (informativ) Andere in dieser Norm
          zitierte Internationale Publikationen mit den
          Verweisungen auf die entsprechenden Europäischen
          Publikationen

Diese Besonderen Festlegungen gelten für ELEKTROMYOGRAPHEN, wie in 2.101 definiert und GERÄTE FÜR EVOZIERTE POTENTIALE, wie in 2.1.102 definiert, nachfolgend als GERÄTE bezeichnet. Der Zweck dieser Besonderen Festlegungen ist es, besondere Anforderungen für die Sicherheit von ELEKTROMYOGRAPHEN und GERÄTEN FÜR EVOZIERTE POTENTIALE, wie In 2.1.101 beziehungsweise 2.1.102 definiert, festzulegen.

DevelopmentNote
DRAFT 2015 issued in September 2015. (09/2015)
DocumentType
Standard
PublisherName
Verband Deutscher Elektrotechniker
Status
Superseded
SupersededBy

Standards Relationship
IEC 60601-2-40:2016 Identical
DIN EN 60601-2-40 : 1998 Identical
EN 60601-2-40:1998 Identical
DIN EN 60601-2-40 : 1998 Corresponds

EN 60645-3:2007 Electroacoustics - Audiometric equipment - Part 3: Test signals of short duration
IEC 60645-3:2007 Electroacoustics - Audiometric equipment - Part 3: Test signals of short duration
EN 60825-1:2014/AC:2017-06 SAFETY OF LASER PRODUCTS - PART 1: EQUIPMENT CLASSIFICATION AND REQUIREMENTS (IEC 60825-1:2014)
DIN EN 60601-1-1 : 2002 MEDICAL ELECTRICAL EQUIPMENT - PART 1-1: GENERAL REQUIREMENTS FOR SAFETY - COLLATERAL STANDARD: SAFETY REQUIREMENTS FOR MEDICAL ELECTRICAL SYSTEMS
IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
VDE 0750-1-2 : 2016 MEDICAL ELECTRICAL EQUIPMENT - PART 1-2: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: ELECTROMAGNETIC DISTURBANCES REQUIREMENTS AND TESTS (IEC 60601-1-2:2014)
IEC 60825-1:2014 Safety of laser products - Part 1: Equipment classification and requirements
EN 60601-1-1:2001 Medical electrical equipment - Part 1-1: General requirements for safety - Collateral standard: Safety requirements for medical electrical systems
IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
EN 60601-1-2:2015 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
DIN EN 60825-1 : 2015-07 SAFETY OF LASER PRODUCTS - PART 1: EQUIPMENT CLASSIFICATION AND REQUIREMENTS (IEC 60825-1:2014)
VDE 0750-1-1 : 2002 MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR SAFETY; 1 COLLATERAL STANDARD: SAFETY REQUIREMENTS FOR MEDICAL ELECTRICAL SYSTEMS
VDE 0837-1 : 2015-07 SAFETY OF LASER PRODUCTS - PART 1: EQUIPMENT CLASSIFICATION AND REQUIREMENT (IEC 60825-1:2014)
VDE 0750-1 : 2013 MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE (IEC 60601-1:2005 + COR.:2006 + COR.:2007 + A1:2012)
IEC 60601-1-1:2000 Medical electrical equipment - Part 1-1: General requirements for safety - Collateral standard: Safety requirements for medical electrical systems
DIN EN 60645-3:2008-01 Electroacoustics - Audiometric equipment - Part 3: Test signals of short duration (IEC 60645-3:2007); German version EN 60645-3:2007

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.