• BS EN 14453:2005

    Current The latest, up-to-date edition.

    Devices to prevent pollution by backflow of potable water. Pipe interrupter with permanent atmospheric vent DN 10 to DN 20. Family D, type C

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  25-01-2006

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Nominal sizes
    5 Designation
    6 Marking and technical documents
    7 Symbolization
    8 General design characteristics
    9 Physico-chemical characteristics
    10 Characteristics and tests
    11 Acoustic characteristics
    Annex A (normative) Sampling and test
            sequence
    Bibliography

    Abstract - (Show below) - (Hide below)

    Defines the characteristics of pipe interrupters with permanent atmospheric vent, DN 10 to DN 20 that are suitable for use in drinking water systems at pressures up to 1 MPa (10 bar) and temperatures up to 65 degree C and for 1 h 90 degree C.

    Scope - (Show below) - (Hide below)

    This document specifies: a) field of application; b) requirements for pipe interrupters with permanent atmospheric vent; c) dimensional, the physico-chemical properties and the properties of general hydraulic, mechanical and acoustic design of pipe interrupters with permanent atmospheric vent, DN 10 to DN 20; d) test method and requirements for verifying these properties; e) marking and presentation; f) acoustics. This document specifies the characteristics of pipe interrupters with permanent atmospheric vent, DN 10 to DN 20 that are suitable for use in drinking water systems at pressures up to 1 MPa (10 bar) and temperatures up to 65 °C and for 1 h 90 °C. Backflow protection devices integrated in flushing valves are similar to DC and are not covered under this document. The requirements are stated in EN 12541. This document specifies: a) field of application; b) requirements for pipe interrupters with permanent atmospheric vent; c) dimensional, the physico-chemical properties and the properties of general hydraulic, mechanical and acoustic design of pipe interrupters with permanent atmospheric vent, DN 10 to DN 20; d) test method and requirements for verifying these properties; e) marking and presentation; f) acoustics. This document specifies the characteristics of pipe interrupters with permanent atmospheric vent, DN 10 to DN 20 that are suitable for use in drinking water systems at pressures up to 1 MPa (10 bar) and temperatures up to 65 °C and for 1 h 90 °C. Backflow protection devices integrated in flushing valves are similar to DC and are not covered under this document. The requirements are stated in EN 12541.

    General Product Information - (Show below) - (Hide below)

    Committee B/504
    Development Note Supersedes BS 6281-3(1982) and 02/103307 DC. (02/2006)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 3822-1:1999 Acoustics Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 1: Method of measurement
    EN 806-1:2000/A1:2001 SPECIFICATIONS FOR INSTALLATIONS INSIDE BUILDINGS CONVEYING WATER FOR HUMAN CONSUMPTION - PART 1: GENERAL
    ISO 3822-4:1997 Acoustics Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 4: Mounting and operating conditions for special appliances
    EN 1717:2000 Protection against pollution of potable water in water installations and general requirements of devices to prevent pollution by backflow
    EN 12541:2002 Sanitary tapware - Pressure flushing valves and automatic closing urinal valves PN 10
    EN ISO 228-1:2003 Pipe threads where pressure-tight joints are not made on the threads - Part 1: Dimensions, tolerances and designation (ISO 228-1:2000)
    EN ISO 3822-4:1997 Acoustics - Laboratory tests on noise emission from appliances and equipment used in water supply installations - Part 4: Mounting and operating conditions for special appliances
    ISO 7-1:1994 Pipe threads where pressure-tight joints are made on the threads Part 1: Dimensions, tolerances and designation
    EN ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003)
    ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements
    ISO 6509:1981 Corrosion of metals and alloys Determination of dezincification resistance of brass
    ISO 9227:2017 Corrosion tests in artificial atmospheres — Salt spray tests
    ISO 3822-3:1997 Acoustics Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 3: Mounting and operating conditions for in-line valves and appliances
    EN ISO 3822-1:1999/A1:2008 ACOUSTICS - LABORATORY TESTS ON NOISE EMISSION FROM APPLIANCES AND EQUIPMENT USED IN WATER SUPPLY INSTALLATIONS - PART 1: METHOD OF MEASUREMENT
    EN ISO 6509 : 1995 CORROSION OF METALS AND ALLOYS - DETERMINATION OF DEZINCIFICATION RESISTANCE OF BRASS
    ISO 228-1:2000 Pipe threads where pressure-tight joints are not made on the threads Part 1: Dimensions, tolerances and designation
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective