• BS EN 54-20:2006

    Current The latest, up-to-date edition.

    Fire detection and fire alarm systems Aspirating smoke detectors

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  30-06-2006

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Symbols and abbreviations
    5 Requirements
       5.1 Compliance
       5.2 Individual visual alarm indication
       5.3 Connection of ancillary devices
       5.4 Manufacturer's adjustments
       5.5 On site adjustment of response behaviour
       5.6 Response to slowly developing fires
       5.7 Mechanical strength of the pipework
       5.8 Hardware components and additional sensing elements
            in the sampling device
       5.9 Airflow monitoring
       5.10 Power supply
       5.11 Data
       5.12 Additional requirements for software controlled
            detectors
    6 Tests
       6.1 General
       6.2 Repeatability
       6.3 Reproducibility
       6.4 Variation in supply parameters
       6.5 Dry heat (operational)
       6.6 Cold (operational)
       6.7 Damp heat, steady state (operational)
       6.8 Damp heat, steady state (endurance)
       6.9 Sulfur dioxide (SO[2]) corrosion (endurance)
       6.10 Shock (operational)
       6.11 Impact (operational)
       6.12 Vibration, sinusoidal (operational)
       6.13 Vibration, sinusoidal (endurance)
       6.14 Electromagnetic compatibility (EMC) immunity tests
       6.15 Fire sensitivity
    7 Classification and designation
    8 Marking
    Annex A (informative) - Apparatus for Response Threshold
                            Value (RTV) measurements
    Annex B (normative) - Smoldering (pyrolysis) wood fire
                            (TF2)
          B.1 Fuel
          B.2 Hotplate
          B.3 Arrangement
          B.4 Heating rate
          B.5 End of test condition
          B.6 Test validity criteria
    Annex C (normative) - Reduced smoldering pyrolysis wood
                            fires (TF2A and TF2B)
          C.1 Fuel
          C.2 Hotplate
          C.3 Arrangement
          C.4 Heating rate
          C.5 End of test condition
          C.6 Test validity criteria
    Annex D (normative) - Glowing smouldering cotton fire
                            (TF3)
          D.1 Fuel
          D.2 Arrangement
          D.3 Ignition
          D.4 End of test condition
          D.5 Test validity criteria
    Annex E (normative) - Reduced glowing smoldering cotton
                            fire (TF3A and TF3B)
          E.1 Fuel
          E.2 Arrangement
          E.3 Ignition
          E.4 End of test condition
          E.5 Test validity criteria
    Annex F (normative) - Flaming plastics (polyurethane)
                            fire (TF4)
          F.1 Fuel
          F.2 Arrangement
          F.3 Ignition
          F.4 End of test condition
          F.5 Test validity criteria
    Annex G (normative) - Flaming liquid (n-heptanes) fire
                            (TF5)
          G.1 Fuel
          G.2 Arrangement
          G.3 Ignition
          G.4 End of test condition
          G.5 Test validity criteria
    Annex H (normative) - Reduced flaming liquid
                            (n-heptanes) fire (TF5A and TF5B)
          H.1 Fuel
          H.2 Arrangement
          H.3 Ignition
          H.4 End of test condition
          H.5 Test validity criteria
    Annex I (normative) - Fire test room and ventilation
                            system
          I.1 Fire test room
          I.2 Ventilation system
    Annex J (informative) - Information concerning the
                            requirements for the response to
                            slowly developing fires
    Annex K (informative) - Apparatus for air flow monitoring
                            test
          K.1 General
          K.2 Airflow measuring with worst-case sampling
               device
          K.3 Airflow monitoring test with test pipe network
    Annex ZA (informative) - Clauses of this European Standard
                             addressing the provisions of the
                             EU Construction Products Directive
          ZA.1 Scope and relevant clauses
          ZA.2 Procedures for the attestation of conformity of
                aspirating smoke detectors covered by this
                standard
          ZA.3 CE Marking and labelling and accompanying
                documentation
          ZA.4 EC certificate and declaration of conformity
    Bibliography

    Abstract - (Show below) - (Hide below)

    Describes the requirements, test methods and performance criteria for aspirating smoke detectors for use in fire detection and fire alarm systems installed in buildings.

    General Product Information - (Show below) - (Hide below)

    Committee FSH/12
    Development Note Supersedes 04/30104415 DC. (08/2006)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS 5839-1(2002) : 2002 FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE
    BS 5839-1:2017 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
    12/30260278 DC : 0 BS 5839-1 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE
    12/30258581 DC : 0 BS 5908-2 - FIRE AND EXPLOSION PRECAUTIONS AT PREMISES HANDLING FLAMMABLE GASES, LIQUIDS AND DUSTS - PART 2: GUIDE TO APPLICABLE STANDARDS AND REGULATIONS
    PD ISO/TR 19814:2017 Information and documentation. Collections management for archives and libraries
    BS 5908-2:2012 Fire and explosion precautions at premises handling flammable gases, liquids and dusts Guide to applicable standards and regulations
    ISO/TR 19814:2017 Information and documentation Collections management for archives and libraries
    BS 5839-1:2013 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
    PD 5454:2012 Guide for the storage and exhibition of archival materials
    07/30171700 DC : DRAFT OCT 2007 BS 5839-1 AMD1 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
    IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
    EN 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
    IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
    EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
    EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
    EN 60068-1:2014 Environmental testing - Part 1: General and guidance
    EN 54-7:2000/A2:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
    EN 54-2:1997/A1:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT
    EN 61386-1:2008 Conduit systems for cable management - Part 1: General requirements
    EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
    EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
    IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
    IEC 60068-2-2a:1976 Supplement A - Basic environmental testing procedures - Part 2: Tests - Tests B: Dry heat
    ISO 9001:2015 Quality management systems — Requirements
    IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
    EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
    EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
    IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
    IEC 61386-1:2008+AMD1:2017 CSV Conduit systems for cable management - Part 1: General requirements
    IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
    EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
    EN 54-4:1997/A2:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 4: POWER SUPPLY EQUIPMENT
    EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction