• 12/30260278 DC : 0

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    BS 5839-1 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE

    Available format(s):  Hardcopy, PDF

    Superseded date:  31-03-2013

    Language(s):  English

    Published date: 

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Section 1: General
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Need for a fire detection and fire alarm
       system and type of system
    5 Categories of system
    6 Exchange of information and definition of
       responsibilities
    7 Variations from the recommendations of this
       standard
    Section 2: Design considerations
    8 Relationship between system Category and
       areas protected
    9 Actuation of other fire protection systems or
       safety facilities
    10 Systems in explosive gas or dust atmospheres
    11 System components
    12 Monitoring, integrity and reliability of circuits
       external to control equipment
    13 Detection zones
    14 Alarm zones
    15 Communication with the fire and rescue service
    16 Audible alarm signals
    17 Visual alarm signals
    18 Fire alarm warnings for people with impaired
       hearing
    19 Staged fire alarms
    20 Manual call points
    21 Types of fire detector and their selection
    22 Spacing and sitting of automatic fire detectors
    23 Control and indicating equipment
    24 Networked systems
    25 Power supplies
    26 Cables, wiring and other interconnections
    27 Radio-linked systems
    28 Electromagnetic compatibility
    29 Electrical safety
    Section 3: Limitation of false alarms
    30 Responsibility for limitation of false alarms
    31 Categories of false alarms
    32 Acceptable rate of false alarms
    33 Causes of false alarms
    34 Design process for limitation of false alarms
    35 Measures to limit false alarms
    Section 4: Installation
    36 Responsibility of installer
    37 Installation practices and workmanship
    38 Inspection and testing of wiring
    Section 5: Commissioning and handover
    39 Commissioning
    40 Documentation
    41 Certification
    42 Acceptance
    43 Verification
    Section 6: Maintenance
    44 Routine testing
    45 Inspection and servicing
    46 Non-routine attention
    Section 7: Users responsibilities
    47 Premises management
    48 Log book
    Annexes
    Annex A (informative) - Choice of appropriate category
            of fire detection and fire alarm system
    Annex B (informative) - Typical noise levels in buildings
    Annex C (normative) - Control and transmission equipment
            for tactile alarm devices provided for
            people with impaired hearing systems
    Annex D (normative) - Method for calculating standby
            battery capacity
    Annex E (informative) - Schematic for design against
            false alarms
    Annex F (informative) - Model format for system log
            book
    Annex G (informative) - Model certificates
    Bibliography

    General Product Information - (Show below) - (Hide below)

    Comment Closes On
    Committee FSH/12/1
    Document Type Draft
    Publisher British Standards Institution
    Status Superseded
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    BS EN 54-23:2010 Fire detection and fire alarm systems Fire alarm devices. Visual alarm devices
    BS 4678-4:1982 Cable trunking Specification for cable trunking made of insulating material
    DD CLC/TS 50398:2009 Alarm systems. Combined and integrated systems. General requirements
    IEC 60702-1:2002+AMD1:2015 CSV Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables
    BS EN 50131-1 : 2006 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS
    BS ISO 7240-15:2014 Fire detection and alarm systems Point-type fire detectors using smoke and heat sensors
    BS EN 61672-1:2013 Electroacoustics. Sound level meters Specifications
    BS EN 54-7:2001 Fire detection and fire alarm systems Smoke detectors. Point detectors using scattered light, transmitted light or ionization
    BS EN 50200:2015 Method of test for resistance to fire of unprotected small cables for use in emergency circuits
    BS EN ISO 13943:2017 Fire safety. Vocabulary
    2004/108/EC : 2004 DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 DECEMBER 2004 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY AND REPEALING DIRECTIVE 89/336/EC
    BS 5839-9:2011 Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems
    BS EN 60702-2 : 2002 MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 2: TERMINATIONS
    BS EN 54-4:1998 Fire detection and fire alarm systems Power supply equipment
    BS EN 54-2 : 1998 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT
    BS EN 54-3:2014 Fire detection and fire alarm systems Fire alarm devices. Sounders
    BS EN 54-5 : 2017 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 5: HEAT DETECTORS - POINT HEAT DETECTORS
    BS EN 60079-14:2014 Explosive atmospheres Electrical installations design, selection and erection
    BS 8434-2(2003) : 2003 METHODS OF TEST FOR ASSESSMENT OF THE FIRE INTEGRITY OF ELECTRIC CABLES - PART 2: TEST FOR UNPROTECTED SMALL CABLES FOR USE IN EMERGENCY CIRCUITS - BS EN 50200 WITH A 930 DEGREE C FLAME AND WITH WATER SPRAY
    BS EN 54-12:2015 Fire detection and fire alarm systems Smoke detectors. Line detectors using an optical beam
    PD 7974-4:2003 Application of fire safety engineering principles to the design of buildings Detection of fire and activation of fire protection systems. (Sub-system 4)
    BS 8434-1:2003 Methods of test for assessment of the fire integrity of electric cables Test for unprotected small cables for use in emergency circuits. BS EN 50200 with addition of water spray
    BS EN 54-10:2002 Fire detection and fire alarm systems Flame detectors. Point detectors
    BS EN 50281-1-2:1999 Electrical apparatus for use in the presence of combustible dust. Electrical apparatus protected by enclosures Selection, installation and maintenance
    BS 7974:2001 Application of fire safety engineering principles to the design of buildings. Code of practice
    BS EN 60702-1 : 2002 MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES
    BS ISO 7240-8:2014 Fire detection and alarm systems Point-type fire detectors using a carbon monoxide sensor in combination with a heat sensor
    BS EN 54-25:2008 Fire detection and fire alarm systems Components using radio links
    BS EN 54-20:2006 Fire detection and fire alarm systems Aspirating smoke detectors
    BS EN 54-11:2001 Fire detection and fire alarm systems Manual call points
    IEC 60702-2:2002+AMD1:2015 CSV Mineral insulated cables and their terminations with a rated voltagenot exceeding 750 V - Part 2: Terminations
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective