FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
3.1 Definitions related to general terms
3.2 Definitions of relay types
4 Influence quantities
5 Rated values
5.1 Control voltage and frequency
5.2 Release voltage
5.3 Power consumption
5.4 Output circuit
5.5 Ambient temperature
5.6 Transport and storage temperature
5.7 Humidity
5.8 Pollution degree
5.9 Altitude
5.10 Timing circuit function
6 General provisions for testing
7 Documentation and marking
7.1 Data
7.2 Marking
8 Heating
8.1 General test conditions
8.2 Heating of Terminals
8.3 Heating of sockets
8.4 Heating of alternative termination types
8.5 Heating of accessible parts
8.6 Heating of insulating materials
9 Basic operating function
9.1 General test conditions
9.2 Operate
9.3 Release
9.4 Time function
10 Insulation
10.1 Preconditioning
10.2 Dielectric strength
10.3 Impulse withstand test
10.4 Dielectric A.C. power frequency voltage test
10.5 Protection against direct contact
11 Electrical endurance
11.1 Resistive loads, inductive loads, and special loads
11.2 Low energy loads
12 Conditional short-circuit current
12.1 Test Procedure
12.2 Test circuit electromechanical output circuit
12.3 Test circuit solid state output circuit
12.4 Condition of switching element after test
13 Clearances, creepage distances and solid insulation
13.1 General provisions
13.2 Measurement of creepage distances and clearances
14 Mechanical strength
14.1 Mechanical strength of terminals and
current-carrying parts
15 Heat and fire resistance
16 Vibration and shock
16.1 Vibration
16.2 Shock
17 Electromagnetic compatibility (EMC)
Annex A (informative) - Ball pressure test
BS EN 61812-1
Committee |
EPL/94
|
DocumentType |
Draft
|
Pages |
43
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
IEC 60947-5-4:2002 | Low-voltage switchgear and controlgear - Part 5-4: Control circuit devices and switching elements - Method of assessing the performance of low-energy contacts - Special tests |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60664-4:2005 | Insulation coordination for equipment within low-voltage systems - Part 4: Consideration of high-frequency voltage stress |
IEC 61984:2008 | Connectors - Safety requirements and tests |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 62314:2006 | Solid-state relays |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
IEC 61810-1:2015 | Electromechanical elementary relays - Part 1: General and safety requirements |
IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60664-5:2007 | Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm |
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV | Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
IEC 61180-1:1992 | High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV | Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests |