FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Classification of insulating liquids
5 Types of electrotechnical equipment containing
insulating liquids
6 Fire parameters
7 Fire scenarios
8 Protective measures against fire
9 Considerations for the selection of test methods
Annex A (informative) - History of insulating liquids
Annex B (informative) - Preventive and protective
measures against fire
Annex C (informative) - Transformers
Annex D (informative) - Power capacitors
Annex E (informative) - Cables
Annex F (informative) - Bushings
Annex G (informative) - Switchgear
Bibliography
BS EN 60695-1-40 Ed 1.0.
Committee |
GEL/89
|
DocumentType |
Draft
|
Pages |
33
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
ISO 2719:2016 | Determination of flash point — Pensky-Martens closed cup method |
IEC 60055-1:1997+AMD1:2005 CSV | Paper-insulated metal-sheathed cables for rated voltages up to 18/30 kV (with copper or aluminium conductors and excluding gas-pressure and oil-filled cables) - Part 1: Tests on cables and their accessories |
IEEE 241 : 1990 | ELECTRIC POWER SYSTEMS IN COMMERCIAL BUILDINGS |
IEC 60695-6-2:2011 | Fire hazard testing - Part 6-2: Smoke obscuration - Summary and relevance of test methods |
IEC 60465:1988 | Specification for unused insulating mineral oils for cables with oil ducts |
IEC 62271-105:2012 | High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV |
IEC 60695-4:2012 | Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products |
ISO 1716:2010 | Reaction to fire tests for products Determination of the gross heat of combustion (calorific value) |
IEC TS 60695-5-2:2002 | Fire hazard testing - Part 5-2: Corrosion damage effects of fire effluent - Summary and relevance of test methods |
NFC 17 300 : 88 AMD 1 1995 | CONDITIONS OF USE OF LIQUID DIELECTRICS - FIRST PART: FIRE RISKS |
IEC TS 60695-8-3:2008 | Fire hazard testing - Part 8-3: Heat release - Heat release of insulating liquids used in electrotechnical products |
IEC 61039:2008 | Classification of insulating liquids |
HD 637 S1:1999/corrigendum:2005 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. |
ISO 13943:2017 | Fire safety — Vocabulary |
IEC 61197:1993 | Insulating liquids - Linear flame propagation - Test method using a glass-fibre tape |
IEC 60794-1-1:2015 | Optical fibre cables - Part 1-1: Generic specification - General |
IEC 61099:2010 | Insulating liquids - Specifications for unused synthetic organic esters for electrical purposes |
IEC 61144:1992 | Test method for the determination of oxygen index of insulating liquids |
IEC 60076-8:1997 | Power transformers - Part 8: Application guide |
IEC 60836:2015 | Specifications for unused silicone insulating liquids for electrotechnical purposes |
IEC 60296:2012 RLV | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
ISO/IEC Guide 51:2014 | Safety aspects — Guidelines for their inclusion in standards |
IEC 61330:1995 | High-voltage/low voltage prefabricated substations |
IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
IEC 60944:1988 | Guide for the maintenance of silicone transformer liquids |
IEC 60695-7-2:2011 | Fire hazard testing - Part 7-2: Toxicity of fire effluent - Summary and relevance of test methods |
IEC 60867:1993 | Insulating liquids - Specifications for unused liquids based on synthetic aromatic hydrocarbons |
IEC 60141-1:1993 | Tests on oil-filled and gas-pressure cables and their accessories - Part 1: Oil-filled, paper or polypropylene paper laminate insulated, metal-sheathed cables and accessories for alternating voltages up to and including 500 kV |
IEC 61203:1992 | Synthetic organic esters for electrical purposes - Guide for maintenance of transformer esters in equipment |
IEC 60963:1988 | Specification for unused polybutenes |
IEC 60695-1-11:2014 | Fire hazard testing - Part 1-11: Guidance for assessing the fire hazard of electrotechnical products - Fire hazard assessment |
IEC 60695-1-10:2016 | Fire hazard testing - Part 1-10: Guidance for assessing the fire hazard of electrotechnical products - General guidelines |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.