Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Smoke control damper requirements
5 Test methods
6 Evaluation of conformity
7 Marking and documentation
8 Product, installation and maintenance information
(documentation)
Annex A (normative) - Salt spray exposure test
Annex B (informative) - Example of inspection and maintenance
procedure
Annex C (normative) - Factory production control - test plan
Bibliography
BS ISO 21927-8.
Committee |
FSH/25
|
DocumentType |
Draft
|
Pages |
36
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
ISO 21927-9:2012 | Smoke and heat control systems — Part 9: Specification for control equipment |
ISO 7244:1984 | Air distribution and air diffusion Aerodynamic testing of dampers and valves |
EN 13501-4:2016 | Fire classification of construction products and building elements - Part 4: Classification using data from fire resistance tests on components of smoke control systems |
ISO 13943:2017 | Fire safety — Vocabulary |
EN ISO 9002:1994/AC:1997 | QUALITY SYSTEMS - SPECIFICATION FOR PRODUCTION AND INSTALLATION |
ISO 21927-10:2011 | Smoke and heat control systems — Part 10: Specification for power output devices |
EN 1366-9:2008 | Fire resistance tests for service installations - Part 9: Single compartment smoke extraction ducts |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
ISO 5135:1997 | Acoustics Determination of sound power levels of noise from air-terminal devices, air-terminal units, dampers and valves by measurement in a reverberation room |
EN 1366-8:2004 | Fire resistance tests for service installations - Part 8: Smoke extraction ducts |
ISO 9001:2015 | Quality management systems — Requirements |
EN 1366-10:2011+A1:2017 | Fire resistance tests for service installations - Part 10: Smoke control dampers |
ISO 21927-3:2006 | Smoke and heat control systems Part 3: Specification for powered smoke and heat exhaust ventilators |
ISO 21927-2:2006 | Smoke and heat control systems Part 2: Specification for natural smoke and heat exhaust ventilators |
ISO 834-1:1999 | Fire-resistance tests Elements of building construction Part 1: General requirements |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
ISO 10294-1:1996 | Fire resistance tests Fire dampers for air distribution systems Part 1: Test method |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-