17/30348256 DC : 0
NA
Status of Standard is Unknown
BS EN 13501-6 - FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES
Hardcopy , PDF
English
European foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Classes of reaction to fire performance
5 Test methods
6 Principles for specimen preparation
7 Number of tests for classification
8 Testing of electric cables
9 Classification criteria for electric cables
10 Presentation of classification
11 Field of application of the classification
12 Classification report
Annex A (normative) - Reaction to fire classification report
for electric cables
Annex B (informative) - Background information as regards
the reaction to fire performance of cables
Bibliography
BS EN 13501-6.
Committee |
FSH/21/-/8
|
DocumentType |
Draft
|
Pages |
32
|
PublisherName |
British Standards Institution
|
Status |
NA
|
Standards | Relationship |
PREN 13501-6 : DRAFT 2017 | Identical |
EN 50399 : 2011 AMD 1 2016 | COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - HEAT RELEASE AND SMOKE PRODUCTION MEASUREMENT ON CABLES DURING FLAME SPREAD TEST - TEST APPARATUS, PROCEDURES, RESULTS |
EN 60754-2:2014 | Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity |
ISO 1716:2010 | Reaction to fire tests for products Determination of the gross heat of combustion (calorific value) |
ISO 13943:2017 | Fire safety — Vocabulary |
IEC 60754-1:2011 | Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content |
EN 50575:2014/A1:2016 | POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
EN 61034-2:2005/A1:2013 | MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 2: TEST PROCEDURE AND REQUIREMENTS (IEC 61034-2:2005/A1:2013) |
EN 60754-1:2014 | Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content |
IEC 60754-2:2011 | Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity |
EN ISO 13943:2017 | Fire safety - Vocabulary (ISO 13943:2017) |
CLC/TS 50576:2016 | Electric cables - Extended application of test results for reaction to fire |
EN ISO 1716:2010 | Reaction to fire tests for products - Determination of the gross heat of combustion (calorific value) (ISO 1716:2010) |
IEC 61034-2:2005+AMD1:2013 CSV | Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.