AAMI DF80:2003
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
MEDICAL ELECTRICAL EQUIPMENT - PART 2-4: PARTICULAR REQUIREMENTS FOR THE SAFETY OF CARDIAC DEFIBRILLATORS [INCLUDING AUTOMATED EXTERNAL DEFIBRILLATORS]
Hardcopy , PDF
14-10-2010
English
01-01-2010
Glossary of equivalent standards
Committee representation
Background
FOREWORD
INTRODUCTION
SECTION ONE - GENERAL
1 Scope and object
2 Terminology and definitions
4 General requirements for tests
5 Classification
6 Identification, marking, and documents
SECTION TWO - ENVIRONMENTAL CONDITIONS
10 Environmental conditions
SECTION THREE - PROTECTION AGAINST ELECTRIC SHOCK HAZARDS
14 Requirements related to classification
17 Separation
19 Continuous LEAKAGE CURRENTS and PATIENT AUXILIARY CURRENTS
20 Dielectric strength
SECTION FOUR - PROTECTION AGAINST MECHANICAL HAZARDS
SECTION FIVE - PROTECTION AGAINST HAZARDS
FROM UNWANTED OR EXCESSIVE RADIATION
36 Electromagnetic compatibility (EMC)
SECTION SIX - PROTECTION AGAINST HAZARDS
OF IGNITION OF FLAMMABLE ANAESTHETIC MIXTURES
SECTION SEVEN - PROTECTION AGAINST
EXCESSIVE TEMPERATURES AND OTHER SAFETY HAZARDS
42 Excessive temperatures
44 Overflow, spillage, leakage, humidity,
ingress of liquids, cleaning, sterilization,
disinfection, and compatibility
46 Human errors
SECTION EIGHT - ACCURACY OF OPERATING DATA
AND PROTECTION AGAINST HAZARDOUS OUTPUT
50 Accuracy of operating data
51 Protection against hazardous output
SECTION NINE - ABNORMAL OPERATION AND FAULT CONDITIONS;
ENVIRONMENTAL TESTS
52 Abnormal operation and fault conditions
SECTION TEN - CONSTRUCTIONAL REQUIREMENTS
56 Components and general assembly
57 MAINS PARTS, components and layout
SECTION 101 - ADDITIONAL REQUIREMENTS RELATING TO SAFETY
101 Charging time
102 Internal electrical power source
103 Endurance
104 Synchronizer
105 Recovery of the MONITOR/ECG INPUT after defibrillation
106 Disturbance to the monitor from charging or internal
discharging
107 Defibrillator electrodes (U.S.)
108 External pacing (U.S.)
Annexes
Appendix L References - Publications mentioned in this Standard
Annex AA (informative) - General guidance and rationale
Annex BB (informative) - AUTOMATED EXTERNAL DEFIBRILLATORS:
background and rationale
Annex CC (informative) - General guidance and rationale
for additional U.S. requirements (U.S.)
Annex DD (informative) - Historical background on
defibrillation waveforms (U.S.)
Annex EE (informative) - Cited references in Annexes CC
and DD (U.S.)
Describes the requirements for the safety of CARDIAC DEFIBRILLATORS as defined in 2.1.101, hereinafter referred to as EQUIPMENT.
Committee |
DF
|
DevelopmentNote |
Supersedes AAMI TIR2. Supersedes AAMI DF2 and AAMI DF39 (11/2003)
|
DocumentType |
Standard
|
Pages |
81
|
ProductNote |
Reconfirmed 2003
|
PublisherName |
Association for the Advancement of Medical Instrumentation
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
IEC 60601-2-4:2010 | Identical |
AAMI DF2 : 3ED 96 | CARDIAC DEFIBRILLATOR DEVICES |
AAMI EC12 : 2000 | DISPOSABLE ECG ELECTRODES |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60601-2-27:2011 | Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment |
IEC 60300-3-9:1995 | Dependability management - Part 3: Application guide - Section 9: Risk analysis of technological systems |
AAMI EC13 : 2002 | CARDIAC MONITORS, HEART RATE METERS AND ALARMS |
IEC 60601-1-1:2000 | Medical electrical equipment - Part 1-1: General requirements for safety - Collateral standard: Safety requirements for medical electrical systems |
IEC 60601-1-4:1996+AMD1:1999 CSV | Medical electrical equipment - Part 1-4: General requirements for safety - Collateral Standard: Programmable electrical medical systems |
AAMI DF39 : 1ED 93 | AUTOMATIC EXTERNAL DEFIBRILLATORS AND REMOTE-CONTROL DEFIBRILLATORS |
IEC 60651:1979+AMD1:1993+AMD2:2000 CSV | Sound level meters |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.