AAMI/IEC TIR62296:2009
Current
The latest, up-to-date edition.
Hardcopy , PDF
English
05-04-2009
Glossary of equivalent standards
Committee representation
Background of AAMI adoption of IEC/TR 62296:2009
FOREWORD
INTRODUCTION
1 Scope and object
1.1 Scope
1.2 Object
2 Recommendations
2.1 Summary of all recommendations prepared by
SC 62A/WG 14
2.2 Recommendation sheets
2.2.1 Separation: Reliability of component impedance
2.2.2 Separation: Non-complying creepage distance and
air clearances
2.2.3 Mains supply transformers: Overload test
2.2.4 Mains supply transformers: Short circuit and
overload tests
2.2.5 Creepage distance and air clearances: Values
2.2.6 Dielectric strength
2.2.7 Failure of components: Evidence of reliability
2.2.8 ENCLOSURES and protective covers
2.2.9 INTERNALLY POWERED EQUIPMENT: 110 percent of
the maximum supply voltage
2.2.10 Creepage distances and air clearances: Values
under 1 mm
2.2.11 Separation: Secondary circuit impedance limit
LEAKAGE CURRENT
2.2.12 ENCLOSURES and PROTECTIVE COVERS: Lampholder/switching
device
2.2.13 Fixing, prevention of maladjustment: Torque test
2.2.14 Batteries not intended to be changed by OPERATOR:
Lithium batteries
2.2.15 Excessive temperatures: Ambient temperatures
2.2.16 Continuous LEAKAGE CURRENTS: Different SUPPLY MAINS
2.2.17 ENCLOSURE and protective covers: EQUIPMENT in ambulances
2.2.18 Dielectric strength: Voltages appearing from external
sources
2.2.19 Testing switch mode power supply units (SMPSU)
2.2.20 Failure of an electrical component: Time periodicity
for detection
2.2.21 Environmental conditions: Compliance paragraph
2.2.22 Limitation of voltage and/or energy: Capacitance
2.2.23 LEAKAGE CURRENTS: Presence of 45 k ohm resistor in
Figure 21
2.2.24 Humidity preconditioning treatment: Exception from
requirement
2.2.25 Dielectric strength: EQUIPMENT containing floating
circuits
2.2.26 General requirements for tests: Measurement uncertainty
2.2.27 CREEPAGE DISTANCES and AIR CLEARANCES: Interpolated values
2.2.28 Overheating: Change of load resistance
2.2.29 Mains operated EQUIPMENT with additional power source:
Integrity of external protective earth
2.2.30 Rechargeable batteries: No OPERATOR/USER maintenance
2.2.31 Isolation from the SUPPLY MAINS: Symbol for single pole
switch
2.2.32 Sequence of testing: Clause 52 before Clause 19
2.2.33 SINGLE FAULT CONDITION: ENCLOSURE LEAKAGE CURRENT from
INTERNALLYY POWERED EQUIPMENT
2.2.34 Marking on the outside of EQUIPMENT: Type and rating
of fuses
2.2.35 Excessive temperatures: APPLIED PARTS not intended to
supply heat
2.2.36 Mains supply transformers: Use of PTCs as protective
devices
2.2.37 Components and general assembly: Reliability of
components
2.2.38 Definition of APPLIED PART: EQUIPMENT worn by PATIENTS
2.2.39 Construction: Triple insulated winding wire
2.2.40 CREEPAGE DISTANCES and AIR CLEARANCES: Dielectric
strength test versus CREEPAGE DISTANCES and AIR
CLEARANCES
2.2.41 CREEPAGE DISTANCES and AIR CLEARANCES: Dielectric
strength test versus CREEPAGE DISTANCES and AIR
CLEARANCES - POWER SUPPLY CORDS
2.2.42 ACCOMPANYING DOCUMENTS: on CD-ROM or electronic file
format
2.2.43 INTERNAL ELECTRICAL POWER SOURCE: Requirements for
lithium batteries
2.2.44 Dielectric strength: Differences between B-d and B-e
2.2.45 Excessive temperatures: Thermocouple instead of
resistance method
2.2.46 Mains fuses and OVER-CURRENT RELEASEs: Fuses in
CLASS II EQUIPMENT
2.2.47 Plug in power supply
2.2.48 Connecting cords between EQUIPMENT parts: Other
applications
2.2.49 MULTIPLE PORTABLE SOCKET-OUTLET
2.2.50 Separation, DEFIBRILLATION-PROOF APPLIED PART:
multiple APPLIED PARTS
2.2.51 Separation, APPLIED PART: Hand held flexible shafts
2.2.52 Protective earthing: No-load voltage of 6 V maximum
2.2.53 Foot-operated control devices: Protection against
entry of liquids
2.2.54 Mains supply transformers
2.2.55 Dielectric strength: Reliability of components to
bridge A-a2 and B-a
2.2.56 Dielectric strength: A-e in switch mode power supply
units (SMPSU)
2.2.57 Dielectric strength: Connection of 12 V dc negative
side to ENCLOSURE
2.2.58 Dielectric strength: Voltages appearing on SIP/SOP
2.2.59 APPLIED PART: EQUIPMENT without APPLIED PART
2.2.60 Scope: Other than MEDICAL ELECTRICAL EQUIPMENT in
contact with the body of a person
2.2.61 Markings: AC symbol
2.2.62 Interruption of power supply: Characteristics of
interruption
2.2.63 Reference voltage: Different reference voltages
in the same circuit
Bibliography
Index of Terms
Provides a series of recommendations developed by an expert working group of IEC subcommittee 62A in response to questions of interpretation of the second edition of IEC 60601-1.
Committee |
ES
|
DocumentType |
Technical Report
|
ISBN |
1570203458
|
Pages |
86
|
PublisherName |
Association for the Advancement of Medical Instrumentation
|
Status |
Current
|
Standards | Relationship |
IEC TR 62296:2009 | Identical |
IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV | Information technology equipment - Safety - Part 1: General requirements |
IEC 60320-1:2015 | Appliance couplers for household and similar general purposes - Part 1: General requirements |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
IEC 60364-7-710:2002 | Electrical installations of buildings - Part 7-710: Requirements for special installations or locations - Medical locations |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
IEC 60884-1:2002+AMD1:2006+AMD2:2013 CSV | Plugs and socket-outlets for household and similar purposes - Part1: General requirements |
IEC 60127-1:2006+AMD1:2011+AMD2:2015 CSV | Miniature fuses - Part 1: Definitions for miniature fuses andgeneral requirements for miniature fuse-links |
IEC 60127-2:2014 | Miniature fuses - Part 2: Cartridge fuse-links |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
IEC 61558-1:2017 | Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC TR 60930:2008 | Guidelines for administrative, medical and nursing staff concerned with the safe use of medical electrical equipment and medical electrical systems |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
IEC 61010-1:2010+AMD1:2016 CSV | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
IEC 60601-1-1:2000 | Medical electrical equipment - Part 1-1: General requirements for safety - Collateral standard: Safety requirements for medical electrical systems |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.