ANSI/CSA NGV 5.1-2016 (R2020)
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Residential fueling appliances
Hardcopy , PDF
10-02-2023
English
01-01-2016
Preface This is the second edition of ANSI/CSA NGV 5.1, Residential fueling appliances. CSA Group acknowledges that the development of this Standard was made possible, in part, by the financial support of the Advanced Research Projects Agency-Energy (ARPA-E), U.S. Department of Energy, under Award Number DE-AR000375. Scope 1.1 General This Standard details mechanical, physical, and electrical requirements for a newly manufactured appliance that dispenses natural gas for vehicles directly into the vehicle natural gas fuel storage system, referred to as a residential fueling appliance (RFA). 1.2 Application These requirements apply to appliances: a) for natural gas only (see Clause 1.1) b) for outdoor or indoor installation in nonliving spaces (e.g., garage) c) for ambient temperature not below minus 40ºC (minus 40 ºF) d) for nominal voltage not exceeding 240 Volts AC e) for fill pressure not exceeding specified vehicle service pressure f) for maximum inlet flow rate not exceeding 10 SCFM (17 SCMH) g) intended for connection to residential utility gas piping system in accordance with requirements of the applicable Code h) intended to meet the installation fire safety requirements in accordance with the requirements of the applicable Code i) single and dual fueling hose gas compressor packages 1.3 Pressure references All references to \"kpa\" and \"psi\" throughout this Standard are to be considered gauge pressures, unless otherwise specified. 1.4 Resolution of conflicts In the case of conflict between this Standard and Federal, National, Provincial, State, or local requirements, the authority having jurisdiction requirements take precedence. 1.5 Units of measure This Standard contains SI (Metric) units corresponding to the inch/pound quantities, the purpose being to allow the standard to be used in SI (Metric) units. If a value for a measurement and a corresponding value in other units are stated, the first stated value is to be regarded as the requirement. The given corresponding value may be approximate. If a value for a measurement and a corresponding value in other units are both specified as a quoted marking requirement, the first stated unit, or both are to be provided. Note: IEEE/ASTM SI 10 or ISO 80000-1 is used as a guide in making metric conversion from inch/pound quantities. 1.6 Terminology In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user shall satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised but not required; and \"may\" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
DocumentType |
Standard
|
ISBN |
978-1-4883-0374-6
|
Pages |
79
|
PublisherName |
Canadian Standards Association
|
Status |
Withdrawn
|
Supersedes |
Preface This is the second edition of ANSI/CSA NGV 5.1, Residential fueling appliances. CSA Group acknowledges that the development of this Standard was made possible, in part, by the financial support of the Advanced Research Projects Agency-Energy (ARPA-E), U.S. Department of Energy, under Award Number DE-AR000375. Scope 1.1 General This Standard details mechanical, physical, and electrical requirements for a newly manufactured appliance that dispenses natural gas for vehicles directly into the vehicle natural gas fuel storage system, referred to as a residential fueling appliance (RFA). 1.2 Application These requirements apply to appliances: a) for natural gas only (see Clause 1.1) b) for outdoor or indoor installation in nonliving spaces (e.g., garage) c) for ambient temperature not below minus 40ºC (minus 40 ºF) d) for nominal voltage not exceeding 240 Volts AC e) for fill pressure not exceeding specified vehicle service pressure f) for maximum inlet flow rate not exceeding 10 SCFM (17 SCMH) g) intended for connection to residential utility gas piping system in accordance with requirements of the applicable Code h) intended to meet the installation fire safety requirements in accordance with the requirements of the applicable Code i) single and dual fueling hose gas compressor packages 1.3 Pressure references All references to \"kpa\" and \"psi\" throughout this Standard are to be considered gauge pressures, unless otherwise specified. 1.4 Resolution of conflicts In the case of conflict between this Standard and Federal, National, Provincial, State, or local requirements, the authority having jurisdiction requirements take precedence. 1.5 Units of measure This Standard contains SI (Metric) units corresponding to the inch/pound quantities, the purpose being to allow the standard to be used in SI (Metric) units. If a value for a measurement and a corresponding value in other units are stated, the first stated value is to be regarded as the requirement. The given corresponding value may be approximate. If a value for a measurement and a corresponding value in other units are both specified as a quoted marking requirement, the first stated unit, or both are to be provided. Note: IEEE/ASTM SI 10 or ISO 80000-1 is used as a guide in making metric conversion from inch/pound quantities. 1.6 Terminology In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user shall satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised but not required; and \"may\" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
IEC 61025:2006 | Fault tree analysis (FTA) |
CSA NGV1 : 2017 | COMPRESSED NATURAL GAS VEHICLE (NGV) FUELING CONNECTION DEVICES |
SAE J200_201506 | Classification System for Rubber Materials |
ASME B18.2.1 : 2012 | SQUARE, HEX, HEAVY HEX, AND ASKEW HEAD BOLTS AND HEX, HEAVY HEX, HEX FLANGE, LOBED HEAD, AND LAG SCREWS (INCH SERIES) |
UL 514A:11ED 2013-02-01 | Metallic Outlet Boxes |
CSA/ANSI NGV1 : 2017 | COMPRESSED NATURAL GAS VEHICLE (NGV) FUELING CONNECTION DEVICES |
ANSI/CSA NGV 4.2-2014 (R2019)/CSA 12.52-2014 (R2018) | Hoses for natural gas dispensing systems |
CSA B51 : 2014 | BOILER, PRESSURE VESSEL, AND PRESSURE PIPING CODE |
IEC 60812:2006 | Analysis techniques for system reliability - Procedure for failure mode and effects analysis (FMEA) |
CSA C22.2 No. 77 : 2014 | MOTORS WITH INHERENT OVERHEATING PROTECTION |
CSA 6.5 : 2015 | AUTOMATIC VALVES FOR GAS APPLIANCES |
SAE J 102 : 1992 | SQUARE HEAD SETSCREWS |
ASME B18.6.4 : 1998 | THREAD FORMING AND THREAD CUTTING TAPPING SCREWS AND METALLIC DRIVE SCREWS, INCH SERIES |
ASTM D 1149 : 2016-02 | TEST METHODS FOR RUBBER DETERIORATION - CRACKING IN AN OZONE CONTROLLED ENVIRONMENT |
CSA C22.2 No. 0.4 : 2004(R2013) | BONDING OF ELECTRICAL EQUIPMENT |
CSA C22.2 No. 0.5 : 2016 | THREADED CONDUIT ENTRIES |
NFPA 79 : 2015 | ELECTRICAL STANDARD FOR INDUSTRIAL MACHINERY |
CSA C22.2 No. 24 : 2015 | TEMPERATURE-INDICATING AND -REGULATING EQUIPMENT |
UL 795:8ED 2016-12-02 | Commercial-Industrial Gas Heating Equipment |
CSA C22.2 No. 139 : 2013 | ELECTRICALLY OPERATED VALVES |
ASME B40.100 : 2013 | Pressure Gauges and Gauge Attachments (B40.100 - 2013) |
CSA 12.3 : 2014 | FUEL SYSTEM COMPONENTS FOR COMPRESSED NATURAL GAS POWERED VEHICLES |
ASME B18.6.2 : 1998 | SLOTTED HEAD CAP SCREWS, SQAURE HEAD SET SCREWS, AND SLOTTED HEADLESS SET SCREWS (INCH SERIES) |
IEEE/ASTM SI_10-2010 | American National Standard for Metric Practice |
SAE J1065_201605 | Nominal Reference Working Pressures for Steel Hydraulic Tubing |
CSA 12.56 : 1999 | MANUALLY OPERATED VALVES FOR NATURAL GAS DISPENSING SYSTEMS |
ASTM D 1822 : 2013 | Standard Test Method for Tensile-Impact Energy to Break Plastics and Electrical Insulating Materials |
SAE J1739_200901 | Potential Failure Mode and Effects Analysis in Design (Design FMEA), Potential Failure Mode and Effects Analysis in Manufacturing and Assembly Processes (Process FMEA) |
MIL-STD-882 Revision E:2012 | System Safety |
NFPA 52 : 2016 | VEHICULAR NATURAL GAS FUEL SYSTEMS CODE |
ASME B36.10M : 2015 | WELDED AND SEAMLESS WROUGHT STEEL PIPE |
ASTM D 865 : 2011 | Standard Test Method for Rubber<char: emdash>Deterioration by Heating in Air (Test Tube Enclosure) |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
SAE J526_201611 | Welded Low-Carbon Steel Tubing Suitable for Bending, Flaring, Beading, Forming and Brazing |
ISO 80000-1:2009 | Quantities and units — Part 1: General |
SAE J525_201609 | Welded and Cold Drawn Low-Carbon Steel Tubing Annealed for Bending and Flaring |
ASTM D 648 : 2016 | Standard Test Method for Deflection Temperature of Plastics Under Flexural Load in the Edgewise Position |
CSA C22.2 No. 100 : 2014 | MOTORS AND GENERATORS |
SAE J1183_201702 | Recommended Guidelines for Fatigue Testing of Elastomeric Materials and Components |
SAE J524_201607 | Seamless Low-Carbon Steel Tubing Annealed for Bending and Flaring |
UL 429:7ED 2013-11-06 | Electrically Operated Valves |
ASTM D 790 : 2010 | Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials |
CFR 49(PTS400-599) : 0 | TRANSPORTATION |
ASME B18.2.2 : 2015 | NUTS FOR GENERAL APPLICATIONS: MACHINE SCREW NUTS, HEX, SQUARE, HEX FLANGE, AND COUPLING NUTS (INCH SERIES) |
ASTM D 5420 : 2016 | Standard Test Method for Impact Resistance of Flat, Rigid Plastic Specimen by Means of a Striker Impacted by a Falling Weight (Gardner Impact) |
SAE J 105 : 1992 | HEX BOLTS |
NFPA 54 : 2018 | NATIONAL FUEL GAS CODE |
C22.2 NO. 236-15 | Heating and cooling equipment (Bi-national standard with UL 1995) |
ASME PV CODE SET : 2017 | BOILER AND PRESSURE VESSEL CODE - COMPLETE SET |
ANSI Z223.1 : 2018 | NATIONAL FUEL GAS CODE |
ASTM D 471 : 2016-02 | TEST METHOD FOR RUBBER PROPERTY - EFFECT OF LIQUIDS |
UL 515:2ED 2015-07-17 | Standard for Electrical Resistance Trace Heating for Commercial Applications |
SAE J 479 : 1992 | SLOTTED HEADLESS SETSCREWS |
UL 60079-0:6ED 2013-07 | Explosive Atmospheres - Part 0: Equipment - General Requirements |
SAE J 478 : A | SLOTTED AND RECESSED HEAD SCREWS |
ASME B18.6.3 : 2013 | MACHINE SCREWS, TAPPING SCREWS, AND METALLIC DRIVE SCREWS (INCH SERIES) |
ASTM D 638 : 2010 | Standard Test Method for Tensile Properties of Plastics |
NFPA 497 : 2017 | CLASSIFICATION OF FLAMMABLE LIQUIDS, GASES, OR VAPORS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.