AS 1202.1-1981
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
A.C. motor starters (up to and including 1000 V) - Direct-on-line (full voltage) starters
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
29-05-2024
English
01-01-1981
Applies to starters intended to start, inch, plug or accelerate a motor to normal speed and to provide means for the protection of the motor and its associated circuits against operating overloads and overheating and to cause the motor to stop. It applies to reversing starters, but does not apply to starters for d.c. motors, static starters for a.c. motors, or control gear for electric traction or for aircraft. Classification and characteristics, operating conditions, constructional requirements and details of tests, including type, routine and special tests, are covered. Technically unchanged from 1972 edition as amended by Amendments 1 and 2.
Committee |
EL-006
|
DocumentType |
Standard
|
ISBN |
0 7262 2289 5
|
Pages |
31
|
ProductNote |
To run concurrently with AS 3947.4.1-1995
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This standard specifies requirements for direct-on-line starters for industrial use, intended to start, inch, plug or accelerate a motor to normal speed and to provide means for the protection of the motor and its associated circuits against operating overloads, and to intentionally cause the motor to stop.This standard applies also to reversing starters. The direct-on-line starters dealt with in this standard are not normally designed to interrupt short-circuit currents. Therefore, suitable short-circuit protection (see Appendix C) should form part of the installation, but not necessarily in the starter.Direct-on-line starters intended for application in merchant ships may also need to comply with supplementary requirements.The standard applies only to starters, the main contacts of which are intended to be connected to circuits the rated voltage of which does not exceed 1000 V a.c. It does not apply to direct-on-line starters intended for installation in rail or road vehicles, or in aircraft, nor are starters for d.c. motors and static starters dealt with.For overload protection reference should be made to AS 1023, Parts 1 to 3.NOTES:1. This standard may, as far as is practicable, apply to either starters or controllers designed to connect the windings of a change-pole motor on any of its various speeds.2. Information to be supplied by the purchaser is listed in Appendix A.
Under Revision See DR 94015
AS 1966.2-1985 | Electric arc welding power sources - Rotary type |
AS 1930-1976 | Circuit-breakers for distribution circuits (up to and including 1000 V a.c. and 1200 V d.c.) |
AS 1966.1-1985 | Electric arc welding power sources - Transformer type |
AS 3439.1-1993 | Low-voltage switchgear and controlgear assemblies Type-tested and partially type-tested assemblies |
AS 2380.1-1989 | Electrical equipment for explosive atmospheres - Explosion-protection techniques General requirements (Reconfirmed 2013) |
AS 3947.3-1994 | Low-voltage switchgear and controlgear Switches, disconnectors, switch-disconnectors and fuse-combination units |
AS 1029.2-1982 | Low voltage contactors - Semiconductor (solid state) (up to and including 1000 V a.c. and 1500 V d.c.) |
AS 2941-1995 | Fixed fire protection installations - Pumpset systems |
AS 1418.1-1994 | Cranes (including hoists and winches) General requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.