1 - AS 1670.2-1997 FIRE DETECTION, WARNING, CONTROL AND INTERCOM SYSTEMS-SYSTEM DESIGN, INSTALLATION AND COMMISSIONING - LOCAL FIRE
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 SCOPE AND GENERAL
6 - 1.1 SCOPE
6 - 1.2 APPLICATION
6 - 1.3 REFERENCED AND RELATED DOCUMENTS
6 - 1.4 DEFINITIONS
6 - 1.4.1 Egress path
6 - 1.4.2 Extra low voltage (ELV)
6 - 1.4.3 Habitable room
6 - 1.4.4 Level surface
6 - 1.4.5 Local fire indicator panel (LFIP)
6 - 1.4.6 Low voltage (LV)
6 - 1.4.7 Multi-station smoke alarms
6 - 1.4.8 Power supply
6 - 1.4.9 Protected area
7 - 1.5 COMPLIANCE WITH OTHER STANDARDS
7 - 1.6 INTERPRETATION OF SPECIFIED LIMITING VALUES
8 - SECTION 2 GENERAL REQUIREMENTS
8 - 2.1 COMPONENTS
8 - 2.2 SEPARATION OF SYSTEMS
9 - SECTION 3 TYPES OF LOCAL FIRE ALARM SYSTEMS
9 - 3.1 SYSTEM TYPES
9 - 3.1.1 General
9 - 3.1.2 Type 1
9 - 3.1.3 Type 2
9 - 3.1.4 Type 3
9 - 3.1.5 Type 4
9 - 3.2 ALARM ZONE LIMITATIONS
9 - 3.2.1 General
9 - 3.2.2 Number of actuating devices
9 - 3.2.3 Concealed spaces
11 - SECTION 4 INSTALLATION REQUIREMENTS
11 - 4.1 GENERAL
11 - 4.2 POWER SOURCE
11 - 4.2.1 Power source (primary)
11 - 4.2.2 Power source (secondary)
11 - 4.3 SEPARATION OF WIRING SYSTEMS
11 - 4.4 CONNECTION TO EXISTING INSTALLATIONS
11 - 4.5 EQUIPMENT AND ITS LOCATION
11 - 4.5.1 General
11 - 4.5.2 Local fire indicator panel
12 - 4.5.3 Detectors
12 - 4.6 WARNING SYSTEMS
12 - 4.7 ANCILLARY LOADS
12 - 4.8 AIRCONDITIONING AND MECHANICAL VENTILATION
12 - 4.9 SUPERVISION
12 - 4.10 INSTALLATION WIRING
12 - 4.10.1 General
13 - 4.10.2 Conductors
13 - 4.10.3 Cable colours
13 - 4.10.4 Joints and terminations
14 - SECTION 5 COMMISSIONING OF INSTALLATION
14 - 5.1 GENERAL
14 - 5.2 COMMISSIONING TESTS
15 - 5.3 STATEMENT OF COMPLIANCE
15 - 5.4 LOG
15 - 5.5 LFIP DOCUMENTATION
17 - APPENDIX A - LIST OF REFERENCED AND RELATED DOCUMENTS
17 - REFERENCED DOCUMENTS
17 - RELATED DOCUMENTS
18 - APPENDIX B - TYPICAL COMMISSIONING TEST REPORT
20 - APPENDIX C - STANDARD FORM OF STATEMENT OF COMPLIANCE FOR LOCAL FIRE ALARM SYSTEMS

Specifies requirements for the design, installation and commissioning of local alarm systems used for early warning fire detection and life safety in situations where there is no legislative requirement for a system, no monitoring station connection requirement, or no monitoring facility available.

Committee
FP-002
DocumentType
Standard
ISBN
0 7337 1604 0
Pages
16
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This Standard sets out the requirements for the system design, installation and commissioning of local fire detection and alarm systems (i.e. not requiring connection to a monitoring service) and components that are manufactured in accordance with the AS 1603 suite of Standards and AS 3786, and fire indicator panels complying with AS 4428.1.These systems are concerned with early warning fire detection and life safety of persons occupying a single building only and do not provide for the connection of subindicator panels.

First published as AS 1670.2-1997.

AS 2484.2-1991 Fire - Glossary of terms Fire protection and firefighting equipment
AS 2380.7-1987 Electrical equipment for explosive atmospheres - Explosion-protection techniques - Intrinsic safety i
AS 4428.6-1997 Fire detection, warning, control and intercom systems - Control and indicating equipment - Alarm signalling equipment
AS 1603.3-1996 Automatic fire detection and alarm systems - Heat alarms
AS 3000-1986 Electrical installations - Buildings, structures and premises (known as the SAA Wiring Rules)
AS 1603.6-1987 Automatic fire detection and alarm systems - Fire alarm bells
AS 3147-1992 Approval and test specification - Electric cables - Thermoplastic insulated - For working voltages up to and including 0.6/1 kV
AS 1851.15-1997 Maintenance of fire protection equipment - Local fire alarm systems
AS 4428.5-1998 Fire detection, warning, control and intercom systems - Control and indicating equipment Power supply units (Reconfirmed 2016)
AS 3786-1993 Smoke alarms
AS 1603.1-1997 Automatic fire detection and alarm systems Heat detectors (Reconfirmed 2016)
AS 2706-1984 Numerical values - Rounding and interpretation of limiting values
AS 1670.1-1995 Fire detection, warning, control and intercom systems - System design, installation and commissioning Fire
AS 1603.2-1997 Automatic fire detection and alarm systems Point type smoke detectors (Reconfirmed 2016)
AS 4428.1-1998 Fire detection, warning, control and intercom systems - Control and indicating equipment Fire (Reconfirmed 2016)
AS 3116-1990 Approval and test specification - Electric cables - Elastomer insulated - For working voltages up to and including 0.6/1 kV

AS 1940:2017 The storage and handling of flammable and combustible liquids
AS 4428.1-1998 Fire detection, warning, control and intercom systems - Control and indicating equipment Fire (Reconfirmed 2016)
AS 1851.15-1997 Maintenance of fire protection equipment - Local fire alarm systems
AS/NZS 3833:1998 The storage and handling of mixed classes of dangerous goods in packages and intermediate bulk containers
AS 1940-2004 The storage and handling of flammable and combustible liquids
AS 4428.10-1998 Fire detection, warning, control and intercom systems - Control and indicating equipment - Alarm investigation
AS/NZS 2022:2003 Anhydrous ammonia - Storage and handling (Reconfirmed 2023)
AS 2201.2-2001 Intruder alarm systems - Monitoring centres
AS 3007.3-2004 Electrical installations - Surface mines and associated processing plant General requirements for equipment and ancillaries
AS/NZS 4681:2000 The storage and handling of Class 9 (miscellaneous) dangerous goods and articles
AS 3786-1993 Smoke alarms
AS 1603.14-2001 Automatic fire detection and alarm systems - Point type carbon monoxide (CO) fire detectors
AS 1603.11-2001 Automatic fire detection and alarm systems - Visual warning devices
AS/NZS 4081:2001 The storage and handling of liquid and liquefied polyfunctional isocyanates (Reconfirmed 2021)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.