AS 1684.2-2006
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Residential timber-framed construction Non-cyclonic areas (SEE IMPORTANT NOTE)
Hardcopy , Hardcopy with incorporated amendment , Looseleaf with incorporated amendment with Binder , Hardcopy Looseleaf with Binder , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
25-07-2024
31-01-2006
This product is available in multiple formats
Hardcopy
This is a traditional bound edition of the new AS 1684.2-2006, with the amendment supplied separately.
Hardcopy incorporating amendment
This is a fully updated edition of AS 1684.2-2006 with Amendment 1 incorporated into the text.
Looseleaf with binder
This is a loose-leafed edition of AS 1684.2-2006, presented in a convenient binder.
Looseleaf with incorporated amendment with binder
This is a fully updated looseleaf edition of AS 1684.2-2006 in a binder with Amendment 1 incorporated into the text.
Specifies requirements for building practice and for the selection, placement and fixing of the various structural elements used in the construction of timber-framed Class 1 and Class 10 buildings, as defined in the Building Code of Australia, for non-cyclonic areas.
Committee |
TM-002
|
DocumentType |
Standard
|
ISBN |
0 7337 7094 0
|
Pages |
0
|
ProductNote |
The CD included with this product is intended to be used on Microsoft PC environment. The PDF format includes as an additional download the complete set of Span Tables (totalling 60MB).
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This Standard specifies requirements for building practice and the selection, placement and fixing of the various structural elements used in the construction of timber-framed Class1 and Class10 buildings as defined by the Building Code of Australia and within the limitations given in Clause1.4. The provisions of this Standard also apply to alterations and additions to such buildings.This Standard also provides building practice and procedures, that assist in the correct specification and determination of timber members, bracing and connections, thereby minimizing the risk of creating an environment that may adversely affect the ultimate performance of the structure.Throughout this Standard, reference is made to the Span Tables in the Supplements. The Supplements are an integral part of, and shall be used in conjunction with, this Standard.This Standard may also be applicable to the design and construction of other classes of buildings where the design criteria, loadings and other parameters applicable to those classes of building are within the limitations of this Standard.NOTES:1 See AS1684.1 for details of design criteria, loadings and other parameters.2 Whilst this Standard can be used to design Class10 buildings, less conservative levels of design for this building class may be permitted by building regulations and other Australian Standards.
First published as AS 056-1946.
Second edition 1948.
Revised and redesignated as AS CA38-1971.
Revised and redesignated as AS 1684-1975.
Third edition 1992.
Revised and redesignated in part as AS 1684.2-1999.
Second edition 2006.
AS/NZS 1859.4:2004 | Reconstituted wood-based panels - Specifications Wet-processed fibreboard |
AS/NZS 1604.3:2004 | Specification for preservative treatment Plywood |
AS/NZS 1604.5:2005 | Specification for preservative treatment Glued laminated timber products |
AS 1214-1983 | Hot-dip galvanized coatings on threaded fasteners (ISO metric coarse thread series) |
AS 3700-2001 | Masonry structures |
AS 1691-1985 | Domestic oil-fired appliances - Installation |
AS/NZS 1170.1:2002 | Structural design actions Permanent, imposed and other actions |
AS 4785.1-2002 | Timber - Softwood - Sawn and milled products Product specification (Reconfirmed 2016) |
AS/NZS 4534:1998 | Zinc and zinc/aluminium-alloy coatings on steel wire |
AS/NZS 1604.4:2004 | Specification for preservative treatment Laminated veneer lumber (LVL) |
AS 1684.4-2006 | Residential timber-framed construction - Simplified Non-cyclonic areas (SEE IMPORTANT NOTE) |
AS 1860-1998 | Installation of particleboard flooring |
AS/NZS 1860.1:2002 | Particleboard flooring Specifications |
AS 3740-2004 | Waterproofing of wet areas within residential buildings |
AS 2796.1-1999 | Timber - Hardwood - Sawn and milled products Product specification (Reconfirmed 2016) |
AS 5604-2005 | Timber - Natural durability ratings (Reconfirmed 2016) |
AS 1720.1-1997 | Timber structures Design methods |
AS 1684.3-2006 | Residential timber-framed construction Cyclonic areas |
AS 1810-1995 | Timber - Seasoned cypress pine - Milled products |
AS 1397-2001 | Steel sheet and strip - Hot-dipped zinc-coated or aluminium/zinc-coated |
AS 4440-2004 | Installation of nailplated timber roof trusses |
AS 2870-1996 | Residential slabs and footings - Construction |
AS 1684.1-1999 | Residential timber-framed construction Design criteria |
AS 4055-2006 | Wind loads for housing |
AS 1720.2-1990 | Timber structures Timber properties |
AS 1604.1-2005 | Specification for preservative treatment Sawn and round timber |
AS/NZS 2918:2001 | Domestic solid fuel burning appliances - Installation |
AS/NZS 1170.2:2002 | Structural design actions Wind actions |
AS/NZS 2269:2004 | Plywood - Structural |
AS/NZS 1170.0:2002 | Structural design actions General principles |
AS/NZS 4791:1999 | Hot-dip galvanized (zinc) coatings on ferrous open sections, applied by an in-line process |
AS/NZS 1604.2:2004 | Specification for preservative treatment Reconstituted wood-based products |
AS 1170.4-1993 | Minimum design loads on structures (known as the SAA Loading Code) Earthquake loads |
HB 52-2000 | The Bathroom Book |
AS 3959-2009 | Construction of buildings in bushfire-prone areas |
AS/NZS 2455.2:2007 | Textile floor coverings - Installation practice - Carpet tiles |
AS/NZS 2455.1:2007 | Textile floor coverings - Installation practice General |
AS 3958.1-2007 | Ceramic tiles Guide to the installation of ceramic tiles |
AS 2050-2002 | Installation of roof tiles |
AS 3959-1999 | Construction of buildings in bushfire-prone areas |
AS 3700-2001 | Masonry structures |
AS 4654.2-2009 | Waterproofing membrane systems for exterior use - Above ground level Design and installation |
AS 3740-2004 | Waterproofing of wet areas within residential buildings |
AS 2082-2007 | Timber - Hardwood - Visually stress-graded for structural purposes (Reconfirmed 2017) |
HB 52-2000 | The Bathroom Book |
AS/NZS 2589:2007 | Gypsum linings - Application and finishing |
AS 1860.2-2006 | Particleboard flooring Installation (Reconfirmed 2016) |
AS/NZS 1748:2006 | Timber - Mechanically stress-graded for structural purposes |
AS 1562.3-2006 | Design and installation of sheet roof and wall cladding Plastic (Reconfirmed 2018) |
AS 1170.4-2007 | Structural design actions Earthquake actions in Australia (Reconfirmed 2018) |
AS 1684.3-2006 | Residential timber-framed construction Cyclonic areas |
AS 1684.4-2006 | Residential timber-framed construction - Simplified Non-cyclonic areas (SEE IMPORTANT NOTE) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.