• Shopping Cart
    There are no items in your cart

AS 2184-1985

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Low voltage switchgear and controlgear - Moulded-case circuit-breakers for rated voltages up to and including 600 V a.c. and 250 V d.c.

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

30-06-2017

Language(s)

English

Published date

01-01-1985

€45.79
Excluding VAT

Deals with characteristics, design and construction, type and routine tests of single-pole and multi-pole moulded-case circuit-breakers, including those which incorporate replaceable current-limiting fuses, for interrupting ratings of 10 kA and above. It may also be used to verify the breaking capacity of moulded-case circuit-breakers within interrupting ratings of 3 kA to 10 kA, which otherwise fall within the scope of AS 3111. Additional requirements may apply to miniature overcurrent circuit-breakers in approvals regulations.

Committee
EL-006
DocumentType
Standard
ISBN
0 7262 3708 6
Pages
22
PublisherName
Standards Australia
Status
Withdrawn
Supersedes

This standard specifies requirements for single-pole and multipole moulded-case air-break circuit-breakers, including circuit-breakers incorporating replaceable current limiting fuses, having voltage ratings up to and including 600 V a.c. and 250 V d.c. and interrupting ratings of 10 kA or more.It does not apply to single-pole and multipole circuit-breakers intended for installation in rail or road vehicles or in aircraft.NOTES:1. Although this standard is intended to apply only to circuit-breakers having an interrupting rating of 10 kA or more, the interrupting rating tests (see Clause 8.2.9) are used to verify claimed breaking capacities between 3 kA and 10 kA of circuit-breakers falling within the scope of AS 3111.2. Additional requirements may apply to miniature over-current circuit-breakers in approvals regulations.

AS 3111-1994 Approval and test specification - Miniature overcurrent circuit-breakers
AS/NZS 3100:2002 Approval and test specification - General requirements for electrical equipment

AS 2676.2-1992 Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings - Sealed cells
AS 1418.14-1996 Cranes (including hoists and winches) Requirements for cranes subject to arduous working conditions
AS 2676.2:2020 Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings Sealed cells
AS 2676.1:2020 Installation, maintenance, testing and replacement of secondary batteries in buildings Vented cells
AS 2467-2008 Maintenance of electrical switchgear
AS 3111-1983 Approval and test specification for miniature overcurrent circuit-breakers
AS 2467-1981 Maintenance of electrical switchgear
AS 3111-1994 Approval and test specification - Miniature overcurrent circuit-breakers
AS 2595.1-1992 Electrical equipment for coal mines - Electrical requirements for underground mining machines and accessories - Equipment for use in hazardous areas
AS/NZS 3012:1995 Electrical installations - Construction and demolition sites
AS 1029.2-1982 Low voltage contactors - Semiconductor (solid state) (up to and including 1000 V a.c. and 1500 V d.c.)
AS 2676.1-1992 Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings - Vented cells
AS 60947.2-2005 Low-voltage switchgear and controlgear - Circuit-breakers
AS 4086.2-1997 Secondary batteries for use with stand-alone power systems Installation and maintenance

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.