AS 2201.2-1992
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Intruder alarm systems - Central stations
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
30-06-2017
English
01-01-1992
Sets out requirements for the grading and comparison of central stations, proprietary stations and remote stations, for the purpose of providing a uniform classification scheme for intruder alarm systems.
Committee |
EL-031
|
DocumentType |
Standard
|
ISBN |
0 7262 7658 8
|
Pages |
13
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This Standard sets out the requirements for grading of central stations, for the purposes of providing a uniform classification scheme for monitoring intruder alarm systems.
First published as part of AS 2201.2-1978.
Second edition 1986.
Revised in part as AS 2201.2-1992.
AS 1715-1982 | Selection, use and maintenance of respiratory protective devices |
AS 2444-1995 | Portable fire extinguishers and fire blankets - Selection and location |
AS 1530.4-1990 | Methods for fire tests on building materials, components and structures Fire-resistance tests of elements of building construction |
AS 1221-1991 | Fire hose reels |
AS 2118-1982 | Automatic fire sprinkler systems (known as the SAA Code for Automatic Fire Sprinkler Systems) |
AS 1847-1985 | Portable fire extinguishers - Carbon dioxide type |
AS 1848-1985 | Portable fire extinguishers - Halon type |
AS 1842-1985 | Portable fire extinguishers - Water and wet chemical (stored pressure) type |
AS 3011.1-1992 | Electrical installations - Secondary batteries installed in buildings - Vented cells Vented cells |
AS 1670-1986 | Automatic fire detection and alarm systems - System design, installation, and commissioning |
AS 1668.2-1991 | The use of mechanical ventilation and air-conditioning in buildings Mechanical ventilation for acceptable indoor-air quality |
AS 1844-1985 | Portable fire extinguishers - Foam (gas container) type |
AS 1840-1976 | Water type portable fire extinguishers - Water (soda acid) type |
AS 3000-1986 | Electrical installations - Buildings, structures and premises (known as the SAA Wiring Rules) |
AS 1843-1976 | Foam (chemical) type portable fire extinguishers |
AS 1841-1985 | Portable fire extinguishers - Water (gas container) type |
AS 1716-1984 | Respiratory protective devices |
AS 2676-1983 | Installation and maintenance of batteries in buildings |
AS 1603-1974 | Thermal detectors for fire alarm installations |
AS 1845-1985 | Portable fire extinguishers - Foam (stored pressure) type |
AS 2293.1-1987 | Emergency evacuation lighting in buildings Design and installation |
AS 1846-1985 | Portable fire extinguishers - Powder type |
AS 2201.1-1998 | Intruder alarm systems Systems installed in client’s premises |
AS 2201.5-1992 | Intruder alarm systems - Alarm transmission systems |
AS 4118.1.4-1994 | Fire sprinkler systems Components - Valve monitors (Reconfirmed 2013) |
AS 2201.1-1998 | Intruder alarm systems Systems installed in client’s premises |
AS 2201.5-1992 | Intruder alarm systems - Alarm transmission systems |
HB 37.4-1994 | Handbook of Australian fire Standards Building materials, products and construction (Reconfirmed 2016) |
AS 2118.1-1995 | Automatic fire sprinkler systems - Standard |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.