• Shopping Cart
    There are no items in your cart

AS 2264-1995

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

A.C. insulation-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 38 kV

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

30-06-2017

Superseded by

AS 62271.201-2008

Language(s)

English

Published date

05-08-1995

€77.79
Excluding VAT

1 - AS 2264-1995 A.C. INSULATION-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 kV AND UP TO AND INCLUDING 38 kV
4 - PREFACE
6 - CONTENTS
8 - 1. Scope
8 - 2. Normal and special service conditions
8 - 3. Definitions
8 - 3.101 Switchgear and controlgear
9 - 3.102 Insulation-enclosed switchgear and controlgear
9 - 3.103 Transport unit
9 - 3.104 Functional unit
9 - 3.105 Insulation enclosure
9 - 3.106 Insulation-embedded component
9 - 3.107 Component
9 - 3.108 Shutter
9 - 3.109 Removable part
10 - 3.110 Withdrawable part
10 - 3.112 Service position/connected position (of a removable part)
10 - 3.113 Earthing position (of a removable part)
10 - 3.114 Test position (of a withdrawable part)
10 - 3.115 Disconnected position (of a withdrawable part)
10 - 3.116 Removed position (of a removable part)
10 - 3.117 Main circuit
10 - 3.118 Auxiliary circuit
11 - 3.119 Rated value
11 - 3.120 Degree of protection
11 - 3.121 Ambient air temperature (of insulation-enclosed switchgear and controlgear)
11 - 3.122 Disruptive discharge
11 - 4. Rating
13 - 5. Design and construction
20 - 6. Type tests
32 - 7. Routine tests
34 - 8. Guide to the selection of switchgear and controlgear for service
35 - 9. Information to be given with enquiries, tenders and orders
36 - 10. Rules for transport, storage, erection and maintenance
38 - APPENDIX AA - INTERNAL FAULT
39 - AA1. Introduction
39 - AA2. Types of accessibility
39 - AA3. Test arrangement
40 - AA4. Current and voltage applied
41 - AA5. Test procedure
42 - AA6. Assessment of the test
43 - AA7. Test report
45 - APPENDIX BB - HUMIDITY TEST
45 - BB1. General
45 - BB2. Test procedure and test conditions
47 - BB3. Test criteria and evaluation
49 - APPENDIX CC - RATED INSULATION LEVEL FOR SERIES II
49 - APPENDIX DD - GUIDE FOR DIELECTRIC TESTS AFTER ERECTION ON SITE
50 - APPENDIX ZZ - LIST OF VARIATIONS BETWEEN THIS STANDARD AND IEC 466
51 - APPENDIX ZA - ITEMS SUBJECT TO AGREEMENT BETWEEN MANUFACTURER AND USER
52 - Amendment 1

Applies to factory-assembled insulation-enclosed switchgear and controlgear for alternating current of rated voltages above 1 kV and up to and including 38 kV for indoor installation and for service frequencies up to and including 60 Hz. This Standard is equivalent in technical content but does not fully correspond in presentation to IEC 466:1987 and Amendment 1:1994.

Committee
EL-007
DocumentType
Standard
ISBN
0 7262 9799 2
Pages
44
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This standard specifies requirements for factory-assembled insulation-enclosed switchgear and controlgear for alternating current of rated voltages above 1 kV and up to and including 38 kV for indoor installation, and for service frequencies up to and including 60 Hz.Note. - In some countries the highest voltage for equipment is 40.5 kV.Insulation-enclosed switchgear and controlgear for special use, for example in flammable atmospheres, in mines or in ships, may be subject to additional requirements.This standard does not deal with components contained in insulation-enclosed switchgear and controlgear for which individual specifications exist.Notes 1. - Switchgear and controlgear assemblies having a metal enclosure are covered by IEC Publication 298:A.C.Metal-enclosed Switchgear and Controlgear for Rated Voltages above 1 kV and up to and including 72.5 kV.2. - While this standard also covers insulation-enclosed switchgear and controlgear the insulation of which is an insulating fluid other than air at atmospheric pressure, additional requirements for such equipment may apply depending on its design.For the purpose of this standard, when the term "switchgear" is used alone, it corresponds to "insulation-enclosed switchgear and controlgear".

First published as AS 2264-1979.
Second edition 1985.
Third edition 1995.

AS 3007.1-2004 Electrical installations - Surface mines and associated processing plant - Scope and definitions
AS 3007.1-1987 Electrical installations - Surface mines and associated processing plant - Scope and definitions
AS 2006-1986 High voltage a.c. switchgear and controlgear - Circuit breakers for rated voltages above 1000 V
AS 1852.151-1988 International electrotechnical vocabulary - Electric and magnetic devices
AS 1255.3-1973 Methods of test for electrical characteristics of solid plastics insulating materials - Determination of electric strength at power frequencies
AS 1939-1990 Degrees of protection provided by enclosures for electrical equipment (IP Code)
AS 2650-1986 High voltage a.c. switchgear and controlgear - Common requirements
AS 1931.1-1996 High-voltage test techniques - General definitions and test requirements
AS 1306-1985 High voltage a.c. switchgear and controlgear - Disconnectors (isolators) and earthing switches
AS 1018-1985 Partial discharge measurements
AS 2086-1995 A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 72.5 kV
AS 1852.441-1985 International electrotechnical vocabulary - Switchgear, controlgear and fuses
AS 2650-2005 Common specifications for high-voltage switchgear and controlgear standards (IEC 60694 Ed.2.2(2002) MOD)

AS 4243-1994 Additional requirements for enclosed switchgear and controlgear from 1 kV to 72.5 kV to be use in severe climatic conditions
AS 2067-1984 Switchgear assemblies and ancillary equipment for alternating voltages above 1 kV
AS 60204.11-2006 Safety of machinery - Electrical equipment of machines Requirements for HV equipment for voltages above 1000 V a.c. or 1500 V d.c and not exceeding 36 kV (IEC 60204-11, Ed. 1.0 (2000) MOD)
AS 2024-1991 High voltage a.c. switchgear and controlgear - Switch-fuse combinations
AS 61330-2005 High-voltage/low-voltage prefabricated substations
AS 2086-1995 A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 72.5 kV

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.