• Shopping Cart
    There are no items in your cart

AS 2488-1995

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Resuscitators intended for use with humans

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

30-06-2017

Published date

05-01-1996

€77.79
Excluding VAT

Specifies performance and safety requirements for ventilatory resuscitators intended for use with humans of all age groups. Automatic pressure cycled gas-powered resuscitators, electrically-powered resuscitators, devices which are designed only to deliver gases to a patient breathing adequately, and devices intended to assist or provide ventilation to a patient for an extended period of time are not covered. The Clauses of this Standard supplement or modify the corresponding Clauses in ISO 8382:1988.

Committee
HE-018
DocumentType
Standard
ISBN
0 7262 9396 2
Pages
33
PublisherName
Standards Australia
Status
Withdrawn
Supersedes

This Standard specifies minimum performance and safety requirements for ventilatory resuscitators intended for use with humans of all age groups. It specifies the performance of operator-powered and gas-powered ventilatory resuscitators which are portable and intended for use in emergency situations to provide lung ventilation to humans whose breathing is inadequate. Requirements for partial rebreathing and circle systems are also included. For gas-powered resuscitators, gas supply requirements are included. Requirements are included for suction systems which may be supplied with the resuscitator. Resuscitators for infants and children are designated according to body mass range and approximate age equivalent. Automatic pressure-cycled gas-powered resuscitators are not dealt with in the Standard because serious under-ventilation is likely if the patient has a high airway resistance or a low compliance of the lungs or chest wall (or both). Such resuscitators are also not suitable for use during external cardiac compression. Electrically powered resuscitators, devices which are designed only to deliver gases to a patient breathing adequately and devices which are intended to assist or provide for the ventilation of a patient for an extended period of time are also not covered by this Standard. Appendix A details test methods, while Appendix B provides tables of resistances and compliances required to set up the test lung.NOTE: Appendix C gives a rationale for various Clauses in this Australian Standard and is included to provide additional insight into the reasoning that led to the requirements and recommendations that have been given. Appendices D and E provide advice concerning materials to be used in resuscitators and face masks.

Standards Relationship
ISO 8382:1988 Corresponds

First published as AS 2488-1981.
Second edition 1995.

AS 2896-1998 Medical gas systems - Installation and testing of non-flammable medical gas pipeline systems
AS 2120.2-1992 Medical suction equipment Manually-powered suction equipment
AS 2120.1-1992 Medical suction equipment Electrically-powered suction equipment Safety requirements
AS/NZS 2496:1995 Breathing attachments for anaesthetic purposes for human use
AS 2472-1996 Valves for medical gas cylinders (Including pin-indexed outlet)
AS 2900.3-2002 Quantities and units - Mechanics
AS 2900.3-1986 Quantities, units, and symbols - Quantities and units of mechanics
AS 2496-1981 Breathing attachments for anaesthetic purposes for human use
AS 2120.3-1992 Medical suction equipment Suction equipment powered from a vacuum or pressure source (Reconfirmed 2016)
AS 2472-1985 Valves for medical gas cylinders

AS/NZS 1715:2009 Selection, use and maintenance of respiratory protective equipment (Reconfirmed 2024)
AS/NZS 1716:2012 Respiratory protective devices (Reconfirmed 2024)
AS/NZS 1716:1994 Respiratory protective devices
AS/NZS 1716:2003 Respiratory protective devices
AS 3848.1-1999 Filling of portable gas cylinders Decant filling of medical air and oxygen into portable cylinders - Safe procedures
AS 1716-1991 Respiratory protective devices

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.