• Shopping Cart
    There are no items in your cart

AS 4055-1992

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Wind loads for housing

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

29-05-2024

Superseded by

AS 4055-2006

Published date

01-01-1992

€57.40
Excluding VAT

1 - AS 4055-1992 WIND LOADS FOR HOUSING
4 - PREFACE
4 - CONTENTS
5 - 1 SCOPE
5 - 2 APPLICATION
5 - 3 REFERENCED DOCUMENTS
5 - 4 DEFINITIONS
5 - 4.1 Average slope
5 - 4.2 Bottom of hill, ridge or escarpment
5 - 4.3 Height
5 - 4.4 House
5 - 4.5 Length
5 - 4.6 Plan
5 - 4.7 Racking forces
5 - 4.8 Width
5 - 5 NOTATION
6 - 6 LIMITATIONS
7 - 7 WIND CLASSIFICATION SYSTEM
9 - 8 TERRAIN CATEGORY CLASSIFICATION
9 - 9 SHIELDING CLASSIFICATION
9 - 10 TOPOGRAPHIC CLASSIFICATION
10 - 11 RACKING FORCES
14 - 12 UPLIFT
15 - APPENDIX A - DERIVATION OF TABLE 1 - WIND CLASSIFICATION SYSTEM
16 - APPENDIX B - PRESSURE COEFFICIENT
16 - B1 INTRODUCTION
16 - B2 WIND CLASSIFICATIONS N1 TO N6
16 - B3 WIND CLASSIFICATIONS C1 TO C4
17 - APPENDIX C - SPACING OF BRACING WALLS FOR HOUSES
19 - APPENDIX D - WORKED EXAMPLE FOR THE CALCULATION OF TOPOGRAPHY
21 - APPENDIX E - WORKED EXAMPLES FOR THE SELECTION OF TERRAIN CATEGORY AND SHIELDING CLASSIFICATION
23 - APPENDIX F - WORKED EXAMPLES FOR RACKING FORCES

This Standard sets out data and procedures for determining design wind speeds and wind loads for housing only. Wind speeds are specified for the serviceability and ultimate strength/stability limit states, and for permissible stress design. Where houses do not comply with the limitations of this Standard, AS 1170.2 should be used.

Committee
BD-099
DocumentType
Standard
ISBN
0 7262 7706 1
Pages
19
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard sets out data and procedures for determining design wind speeds and wind loads for housing.Alternatively, design wind speeds and wind loads for housing may be obtained using AS 1170.2.

First published as AS 4055-1992.

AS 1170.2-1989 Minimum design loads on structures (known as the SAA Loading Code) Wind loads
AS 1170.1-1981 Minimum design loads on structures (known as the SAA Loading Code) Dead and live loads

AS/NZS 4666:2000 Insulating glass units
HB 132.2-1999 Structural upgrading of older houses Cyclone areas
AS/NZS 4504.2:1998 Domestic garage doors - Methods of test Wind pressure test
AS 3600-2001 Concrete structures
AS 2050-1995 Installation of roof tiles
AS 2047-1999 Windows in buildings - Selection and installation
AS 3600-1994 Concrete structures
HB 132.1-1999 Structural upgrading of older houses Non-cyclone areas
AS 3700-1998 Masonry structures
AS 2050-2002 Installation of roof tiles
AS 3623-1993 Domestic metal framing (Reconfirmed 2018)
AS 4440-1997 Installation of nailplated timber trusses
AS/NZS 2589.1:1997 Gypsum linings in residential and light commercial construction - Application and finishing Gypsum plasterboard
AS/NZS 4200.1:1994 Pliable building membranes and underlays Materials
AS 3700-2001 Masonry structures
AS 4597-1999 Installation of roof slates and shingles (Non-interlocking type) (Reconfirmed 2015)
AS 2047.1-1996 Windows in buildings - Specification for materials and performance
AS/NZS 2588:1998 Gypsum plasterboard (Reconfirmed 2016)
AS 2049-2002 Roof tiles (Reconfirmed 2015)
AS/NZS 4505:1998 Domestic garage doors
AS 4440-2004 Installation of nailplated timber roof trusses
AS/NZS 2785:2000 Suspended ceilings - Design and installation
AS/NZS 2589.2:1997 Gypsum linings in residential and light commercial construction - Application and finishing - Fibre reinforced gypsum plaster

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.