AS/NZS 1591.1:1995

AvailableSuperseded

AvailableSuperseded

An Available Superseded Standard is one, which has been made available for a period of time although it has been formally superseded by another Standard. Its availability is maintained where it is referenced in legislation/regulations or in other Standards and its use should be restricted to where so referenced. No responsibility is taken by SAI Global as to the ongoing technical validity of such a Standard, the responsibility resting with the referencing authority.

Acoustics - Instrumentation for audiometry Reference zero for the calibration of pure-tone bone conduction audiometers (Reconfirmed 2014)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

05-09-1995

€32.89
Excluding VAT

1 - AS/NZS 1591.1:1995 ACOUSTICS - INSTRUMENTATION FOR AUDIOMETRY - REFERENCE ZERO FOR THE CALIBRATION OF PURE-TONE BONE CONDUCT
4 - PREFACE
5 - CONTENTS
6 - INTRODUCTION
9 - 1 Scope
9 - 2 Normative references
10 - 3 Definitions
10 - 3.1 bone conduction:
10 - 3.2 bone vibrator:
10 - 3.3 alternating force level (force level)
10 - 3.4 mechanical coupler:
10 - 3.5 equivalent threshold force level
10 - 3.6 reference equivalent threshold force level (RETFL)
10 - 3.7 hearing level
10 - 3.8 occlusion effect:
10 - 3.9 masking:
10 - 3.10 datum level of masking noise:
10 - 3.11 critical bandwidth:
10 - 3.12 vibrotactile threshold level:
10 - 3.13 white noise:
11 - 4 Reference equivalent threshold force levels (RETFLs)
11 - 5 Test conditions and requirements
11 - 5.1 Bone vibrator
11 - 5.2 Fitting of the bone vibrator
11 - 5.3 Mechanical coupler
11 - 5.4 Test signal
12 - 5.5 Masking noise
12 - 5.6 Masking transducer
12 - 5.7 Fitting of masking transducer
12 - 5.8 Datum level of masking noise
13 - Annex A - Note on the derivation of RETFL values
14 - Annex B - Guidance on the application of the reference zero to the calibration of bone-conduction audiometers
14 - B.1 General
14 - B.2 Choice and fitting of bone vibrator
14 - B.3 Calibration of the bone vibrator
14 - B.4 Choice and fitting of masking transducer
14 - B.5 Masking noise source
15 - Annex C - Interim differences in reference equivalent threshold force levels between forehead and mastoid location of vibrato
17 - Annex D - Bone-conduction threshold of hearing for frequencies below 250 Hz
18 - Annex E - Bibliography

Specifies reference equivalent threshold force levels, essential characteristics of the bone vibrator and levels of masking noise applied to the ear not under test. These are applicable to the calibration of bone vibrators for pure-tone bone conduction audiometry. It is identical with and has been reproduced from ISO 389-3:1994.

Committee
AV-003
DocumentType
Standard
ISBN
0 7262 9855 7
Pages
10
ProductNote
Reconfirmed 04/07/2014.This standard has been reconfirmed in Australia in 2014 and remains current in New Zealand. Reconfirmation Notice 4/07/2014
PublisherName
Standards Australia
Status
AvailableSuperseded
SupersededBy
Supersedes

This part of ISO 389 specifies the following data applicable to the calibration of bone vibrators for pure-tone bone-conduction audiometry.a) Reference equivalent threshold force levels (RETFLs), corresponding to the threshold of hearing of young otologically normal persons by bone-conduction audiometry. RETFL is the vibratory force level transmitted to a mechanical coupler of specified characteristics (see 5.3) by a vibrator when applied to the mechanical coupler under stated conditions of test and when energized at the voltage level corresponding to the normal threshold of hearing for location on the mastoid prominence.NOTE 1 Interim values for the differences in reference equivalent threshold force levels between location on the forehead and mastoid are included for information in annex C.b) Essential characteristics of the bone vibrator and of its method of coupling to a person under test and to the mechanical coupler.c) Essential characteristics and datum level of the masking noise applied to the ear not under test.Guidance on the practical application of this part of ISO 389 in the calibration of audiometers is given in annex B.NOTE 2 Recommended procedures for carrying out bone-conduction audiometry are specified in ISO 8253-1.

Standards Relationship
ISO 389-3:1994 Identical

First published as Joint Standard AS/NZS 1591.1:1995.

AS 1591.2-1987 Acoustics - Instrumentation for audiometry - Reference zero for the calibration of pure-tone audiometers
AS/NZS 1591.4:1995 Acoustics - Instrumentation for audiometry A mechanical coupler for calibration of bone vibrators

AS/NZS 1591.4:1995 Acoustics - Instrumentation for audiometry A mechanical coupler for calibration of bone vibrators

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.