AS/NZS 1591.1:1995
AvailableSuperseded
An Available Superseded Standard is one, which has been made available for a period of time although it has been formally superseded by another Standard. Its availability is maintained where it is referenced in legislation/regulations or in other Standards and its use should be restricted to where so referenced. No responsibility is taken by SAI Global as to the ongoing technical validity of such a Standard, the responsibility resting with the referencing authority.
Acoustics - Instrumentation for audiometry Reference zero for the calibration of pure-tone bone conduction audiometers (Reconfirmed 2014)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
05-09-1995
Specifies reference equivalent threshold force levels, essential characteristics of the bone vibrator and levels of masking noise applied to the ear not under test. These are applicable to the calibration of bone vibrators for pure-tone bone conduction audiometry. It is identical with and has been reproduced from ISO 389-3:1994.
Committee |
AV-003
|
DocumentType |
Standard
|
ISBN |
0 7262 9855 7
|
Pages |
10
|
ProductNote |
Reconfirmed 04/07/2014.This standard has been reconfirmed in Australia in 2014 and remains current in New Zealand. Reconfirmation Notice 4/07/2014
|
PublisherName |
Standards Australia
|
Status |
AvailableSuperseded
|
SupersededBy | |
Supersedes |
This part of ISO 389 specifies the following data applicable to the calibration of bone vibrators for pure-tone bone-conduction audiometry.a) Reference equivalent threshold force levels (RETFLs), corresponding to the threshold of hearing of young otologically normal persons by bone-conduction audiometry. RETFL is the vibratory force level transmitted to a mechanical coupler of specified characteristics (see 5.3) by a vibrator when applied to the mechanical coupler under stated conditions of test and when energized at the voltage level corresponding to the normal threshold of hearing for location on the mastoid prominence.NOTE 1 Interim values for the differences in reference equivalent threshold force levels between location on the forehead and mastoid are included for information in annex C.b) Essential characteristics of the bone vibrator and of its method of coupling to a person under test and to the mechanical coupler.c) Essential characteristics and datum level of the masking noise applied to the ear not under test.Guidance on the practical application of this part of ISO 389 in the calibration of audiometers is given in annex B.NOTE 2 Recommended procedures for carrying out bone-conduction audiometry are specified in ISO 8253-1.
Standards | Relationship |
ISO 389-3:1994 | Identical |
First published as Joint Standard AS/NZS 1591.1:1995.
AS 1591.2-1987 | Acoustics - Instrumentation for audiometry - Reference zero for the calibration of pure-tone audiometers |
AS/NZS 1591.4:1995 | Acoustics - Instrumentation for audiometry A mechanical coupler for calibration of bone vibrators |
AS/NZS 1591.4:1995 | Acoustics - Instrumentation for audiometry A mechanical coupler for calibration of bone vibrators |