A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Electrical installations - Marinas and recreational boats Marinas

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

11-07-2024

Superseded by

AS/NZS 3004.1:2014

Language(s)

English

Published date

19-11-2008

€65.33
Excluding VAT

1 - AS/NZS 3004.1:2008 ELECTRICAL INSTALLATIONS-MARINAS AND RECREATIONAL BOATS - MARINAS
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 SCOPE AND GENERAL
6 - 1.1 SCOPE
6 - 1.2 APPLICATION
6 - 1.3 REFERENCED DOCUMENTS
7 - 1.4 DEFINITIONS
7 - 1.4.1 Accessible, readily
7 - 1.4.2 Detachable connection
7 - 1.4.3 Direct connection
7 - 1.4.4 Galvanic isolator
7 - 1.4.5 Marina
7 - 1.4.6 Recreational boats
8 - 1.4.7 Service pillar
8 - 1.5 ALTERATIONS, ADDITIONS AND REPAIRS
8 - 1.6 MARINE ENVIRONMENT ELECTRICAL SAFETY CONSIDERATIONS
8 - 1.6.1 Scope
8 - 1.6.2 Additional risk factors
8 - 1.6.3 Additional protection for equipment safety and instruction labels
8 - 1.6.4 Unacceptable measures against electric shock
8 - 1.7 MINIMIZATION OF GALVANIC CORROSION
9 - 1.8 ACCEPTABLE METHODS OF CONNECTION TO RECREATIONAL BOATS
10 - SECTION 2 MARINA ELECTRICAL INSTALLATION
10 - 2.1 WIRING DETAILS
10 - 2.1.1 General
10 - 2.1.2 Selection of electrical wiring systems
10 - 2.1.3 Earthing system
11 - 2.2 MAXIMUM DEMAND
11 - 2.2.1 Mains and submains
11 - 2.3 ISOLATING TRANSFORMERS
11 - 2.3.1 General
11 - 2.3.2 Protection
11 - 2.4 SWITCHBOARDS PROVIDING LOW-VOLTAGE ELECTRICAL SUPPLY TO RECREATIONAL BOATS
11 - 2.4.1 General
11 - 2.4.2 Service pillars
14 - 2.4.3 Other switchboards
14 - 2.5 OTHER SOCKET-OUTLETS
15 - SECTION 3 CONNECTION OF RECREATIONAL BOATS TO A MARINA LOW-VOLTAGE ELECTRICAL INSTALLATION
15 - 3.1 SUPPLY LEAD
15 - 3.1.1 General
15 - 3.1.2 Technical details
15 - 3.1.3 Length
16 - 3.1.4 Coiled leads
16 - 3.2 INSTALLATION OF SUPPLY LEAD
16 - 3.3 EARTHING
16 - 3.3.1 General
16 - 3.3.2 Supply through a shore-mounted isolating transformer
17 - 3.3.3 Supply through an on-board isolating transformer
17 - 3.3.4 Supply without an isolating transformer
18 - SECTION 4 NEW INSTALLATIONS OR ADDITIONS
18 - 4.1 PERIODIC VERIFICATION-AUSTRALIA
18 - 4.1.1 Testing requirements
18 - 4.1.2 Recording of results
18 - 4.2 PERIODIC VERIFICATION-NEW ZEALAND
18 - 4.2.1 Inspection requirements
19 - 4.2.2 Testing requirements
19 - 4.2.3 Testing of RCDs
19 - 4.2.4 Testing of isolating transformers
19 - 4.2.5 Certificate of Verification
20 - APPENDIX A - BERTHING INSTRUCTIONS FOR CONNECTION TO THE MARINA LOW-VOLTAGE ELECTRICAL SUPPLY THROUGH A SHORE°MOUNTED...
21 - APPENDIX B - BERTHING INSTRUCTIONS FOR CONNECTION TO THE MARINA LOW-VOLTAGE ELECTRICAL SUPPLY THROUGH AN ON-BOARD...
22 - APPENDIX C - MARINA LOW-VOLTAGE ELECTRICAL SUPPLY CONFIGURATIONS
24 - APPENDIX D - CALCULATION OF MAXIMUM DEMAND
24 - D1 INTRODUCTION
24 - D2 PROPOSED CALCULATION VALUES
24 - D2.1 General
24 - D2.2 Amenities
24 - D2.3 Service pillars
25 - D3 DETERMINATION OF CALCULATED MAXIMUM DEMAND
26 - APPENDIX E - CERTIFICATION OF VERIFICATION Œ NEW ZEALAND ONLY

Specifies requirements for electrical installations associated with marinas supplied at low-voltage a.c. supply systems (i.e. exceeding 50V a.c. but not exceeding 1000V a.c.).

Committee
EL-001
DocumentType
Standard
ISBN
0 7337 8941 2
Pages
21
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This Part of AS/NZS 3004 sets out requirements for electrical installations associated with marinas supplied at low-voltage a.c. supply systems (i.e. exceeding 50 V a.c. but not exceeding 1 000 V a.c.).It includes requirements for electrical installations in marinas intended to supply electrical power to recreational boats. The requirements for installations in recreational boats are given in Part 2 of this Standard.It includes requirements for the periodic inspection and testing of marinas.NOTE: This Standard does not require specific instruction notices to be provided either on a recreational boat or on a marina. However, it is recommended that the marina operator provide each recreational boat operator intending to connect a recreational boat to the marina low-voltage electrical supply with a copy of an instruction notice containing at least the information set out in Appendix A or Appendix B, as appropriate.

Originated as part of AS 3004-1979.
Previous edition part of AS/NZS 3004:2002.
Jointly revised and redesignated (in part) as AS/NZS 3004.1:2008.

AS/NZS 61558.2.6:2001 Safety of power transformers, power supply units and similar Particular requirements for safety isolating transformers for general use (IEC 61558-2-6:1997, MOD)
AS/NZS 3123:2005 Approval and test specification - Plugs, socket-outlets and couplers for general industrial application (Reconfirmed 2016)
AS/NZS 60320.2.1:2004 Appliance couplers for household and similar general purposes Sewing machine couplers (IEC 60320-2-1, Ed. 2.0 (2000) MOD) (Reconfirmed 2016)
AS/NZS 60320.1:2004 Appliance couplers for household and similar general purposes General requirements (IEC 60320-1, Ed. 2.0 (2001) MOD)
AS/NZS 3120:1999 Approval and test specification - Cord extension sockets
AS/NZS 3760:2003 In-service safety inspection and testing of electrical equipment
AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS 2832.3-2005 Cathodic protection of metals Fixed immersed structures
AS/NZS 61009.1:2004 Residual current operated circuit breakers with integral overcurrent protection for household and similar uses (RCBOs) General rules (IEC 61009-1, Ed. 2.1 (2003) MOD)
AS/NZS 3004.2:2008 Electrical installations - Marinas and recreational boats Recreational boats installations
AS/NZS 3191:2008 Electric flexible cords (Reconfirmed 2019)
AS 2832.4-2006 Cathodic protection of metals Internal surfaces (Reconfirmed 2016)
AS 60529-2004 Degrees of protection provided by enclosures (IP Code) (Reconfirmed 2018)
AS/NZS 3112:2004 Approval and test specification - Plugs and socket-outlets
AS/NZS 5000.1:2005 Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2017)
AS 2832.5-2008 Cathodic protection of metals Steel in concrete structures
AS/NZS 60320.2.2:2004 Appliance couplers for household and similar general purposes Interconnection couplers for household and similar equipment (IEC 60320-2-2, Ed. 2.0 (1998) MOD) (Reconfirmed 2016)
AS 2832.1-2004 Cathodic protection of metals Pipes and cables
AS 2832.2-2003 Cathodic protection of metals Compact buried structures

AS/NZS 5761:2011 In-service safety inspection and testing - Second-hand equipment prior to sale
AS/NZS 3004.2:2008 Electrical installations - Marinas and recreational boats Recreational boats installations
AS/NZS 5762:2011 In-service safety inspection and testing - Repaired electrical equipment

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.