AS/NZS 5139:2019
Current
The latest, up-to-date edition.
Electrical installations - Safety of battery systems for use with power conversion equipment
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
11-10-2019
AS NZS 5139 2019 specifies requirements for general installation and safety requirements for battery energy storage systems (BESSs), where the battery system is installed in a location, such as a dedicated enclosure or room, and is connected with power conversion equipment (PCE) to supply electric power to other parts of an electrical installation.
Committee |
EL-042
|
DocumentType |
Standard
|
ISBN |
978 1 76072 586 0
|
Pages |
160
|
PublisherName |
Standards Australia
|
Status |
Current
|
Supersedes |
This Standard sets out general installation and safety requirements for battery energy storage systems (BESSs), where the battery system is installed in a location, such as a dedicated enclosure or room, and is connected with power conversion equipment (PCE) to supply electric power to other parts of an electrical installation.
This Standard sets out the requirements from the battery system up to but not including the PCE. This Standard also applies to pre-assembled integrated battery energy storage systems, which also include PCE(s).
This Standard outlines the potential hazards that are associated with battery energy storage systems and their associated battery systems and specifies installation methods that minimize risks posed by these hazards.
This Standard is applicable for the following battery systems:
(a) Nominal voltage between 12 V d.c. and 1500 V d.c.
(b) Connected to either single or multiple PCEs.
(c) Using secondary or rechargeable cells.
(d) With a rated capacity equal to or greater than 1 kWh and no more than 200 kWh, at —
(i) C10 rating, for lead acid batteries; or
(ii) 0.1C, for lithium technologies; or
(iii) manufacturer’s specified energy capacity, for other technologies.
Where an installation includes multiple battery energy storage systems, this Standard applies to each individual battery energy storage system if —
(A) the total energy storage capacity is equal to or greater than 1 kWh; and
(B) each individual BESS is no more than 200 kWh.
This Standard does not apply to battery systems in the following electrical installation types:
(1) Premises with critical power continuity requirements (e.g. acute care hospitals, substation support and black start).
(2) Telecommunication applications.
(3) Electric vehicles.
(4) Portable equipment.
(5) Uninterruptible power systems (UPS) that are in accordance with AS 62040.1.1 and AS 62040.1.2.
(6) Transportable structures and vehicles that are in accordance with AS/NZS 3001.
NOTE 1 While this Standard applies to systems of up to 200 kWh, the general requirements of this Standard may apply to larger installations.
NOTE 2 This Standard applies for common BESS technologies, and is not specifically written to support all types of battery system installation types or for other storage technologies, e.g. super capacitors. This Standard may be able to be applied in full or in part to the different storage technologies, or the risk approach may be used to assess the hazards and determine mitigations.
Originated in Australia as AS 4086.2-1997.
Jointly revised and redesignated as AS/NZS 5139:2019.
AS 60947.3:2018 | Low voltage switchgear and controlgear Switches, disconnectors, switch-disconnectors and fusecombination units (IEC 60947-3:2015 (ED. 3.2) MOD) |
AS 4029.1-1994 | Stationary batteries - Lead-acid Vented type (based on and including the full text of IEC 896-1) |
ISO 9773:1998 | Plastics — Determination of burning behaviour of thin flexible vertical specimens in contact with a small-flame ignition source |
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV | Low-voltage fuses - Part 1: General requirements |
AS/NZS 4777.1:2016 | Grid connection of energy systems via inverters Installation requirements |
AS/NZS 3008.1.1:2017 | Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions |
IEC 60896-21:2004 | Stationary lead-acid batteries - Part 21: Valve regulated types - Methods of test |
AS/NZS 3008.1.2:2017 | Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand conditions |
SAA/SNZ HB 76:2010 | Dangerous Goods - Initial Emergency Response Guide |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
AS/NZS IEC 60947.1:2015 | Low-voltage switchgear and controlgear General rules |
AS 62040.1.1-2003 | Uninterruptible power systems (UPS) General and safety requirements for UPS used in operator access areas |
AS/NZS 4029.2:2000 | Stationary batteries - Lead-acid Valve-regulated type (IEC 60896-2:1995, MOD) |
AS 3731.1-1995 | Stationary batteries - Nickel-cadmium Vented type |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
AS/NZS 3001:2008 | Electrical installations - Transportable structures and vehicles including their site supplies |
IEC 60896-22:2004 | Stationary lead-acid batteries - Part 22: Valve regulated types - Requirements |
IEC 60269-3:2010+AMD1:2013 CSV | Low-voltage fuses - Part 3: Supplementary requirements for fuses foruse by unskilled persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F |
AS/NZS IEC 60947.2:2015 | Low-voltage switchgear and controlgear Circuit-breakers |
AS/NZS 60079.14:2017 | Explosive atmospheres Design selection, erection and initial inspection (IEC 60079-14:2013 (ED.5.0) MOD) |
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 4777.2:2015 | Grid connection of energy systems via inverters Inverter requirements |
AS 62040.1.2-2003 | Uninterruptible power systems (UPS) General and safety requirements for UPS used in restricted access locations |
IEC 60896-11:2002 | Stationary lead-acid batteries - Part 11: Vented types - General requirements and methods of tests |
AS/NZS 5000.1:2005 | Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2017) |
AS/NZS 1680.1:2006 | Interior and workplace lighting General principles and recommendations |
AS/NZS 1170.1:2002 | Structural design actions Permanent, imposed and other actions |
AS/NZS 1170.2:2011 | Structural design actions Wind actions (Reconfirmed 2016) |
AS 1170.4-2007 | Structural design actions Earthquake actions in Australia (Reconfirmed 2018) |
AS/NZS 5033:2014 | Installation and safety requirements for photovoltaic (PV) arrays |
AS/NZS ISO 31000:2009 | Risk management - Principles and guidelines |
AS 1530.1-1994 | Methods for fire tests on building materials, components and structures Combustibility test for materials (Reconfirmed 2016) |
IEC 62109-1:2010 | Safety of power converters for use in photovoltaic power systems - Part 1: General requirements |
AS/NZS 60898.2:2004 | Circuit-breakers for overcurrent protection for household and similar installations Circuit-breakers for a.c. and d.c. operation (IEC 60898-2, Ed. 1.1 (2003) MOD) (Reconfirmed 2016) |
AS/NZS 3112:2017 | Approval and test specification - Plugs and socket-outlets |
AS/NZS 4509.1:2009 | Stand-alone power systems Safety and installation (Reconfirmed 2017) |
AS/NZS 5000.2:2006 | Electric cables - Polymeric insulated For working voltages up to and including 450/750 V (Reconfirmed 2017) |
AS 3731.2-1995 | Stationary batteries - Nickel-cadmium Valve-regulated type |
IEC 60695-11-20:2015 | Fire hazard testing - Part 11-20: Test flames - 500 W flame test method |
ISO 9772:2012 | Cellular plastics Determination of horizontal burning characteristics of small specimens subjected to a small flame |
AS 3011.2:2019 | Electrical installations - Secondary batteries installed in buildings Sealed cells |
AS 2676.2:2020 | Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings Sealed cells |
AS 2676.1:2020 | Installation, maintenance, testing and replacement of secondary batteries in buildings Vented cells |
AS 3011.1:2019 | Electrical installations - Secondary batteries installed in buildings Vented cells |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.