AS/NZS 60079.17:2009
AvailableSuperseded
An Available Superseded Standard is one, which has been made available for a period of time although it has been formally superseded by another Standard. Its availability is maintained where it is referenced in legislation/regulations or in other Standards and its use should be restricted to where so referenced. No responsibility is taken by SAI Global as to the ongoing technical validity of such a Standard, the responsibility resting with the referencing authority.
Explosive atmospheres Electrical installations inspection and maintenance (IEC 60079-17, Ed.4.0 (2007) MOD)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
18-09-2009
Adopts IEC 60079-17 Ed.4.0 with national modifications to cover factors directly related to inspection and maintenance of electrical installations within hazardous areas where the hazard may be caused by flammable gases, vapours, mists, dusts, fibres or flyings.
Committee |
EL-014
|
DocumentType |
Standard
|
ISBN |
0 7337 9243 X
|
Pages |
37
|
PublisherName |
Standards Australia
|
Status |
AvailableSuperseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
First published as AS/NZS 60079.17:2009.
AS/NZS 60079.26:2007 | Explosive atmospheres Equipment with equipment protection level (EPL) Ga |
AS/NZS 60079.20:2000 | Electrical apparatus for explosive gas atmospheres Data for flammable gases and vapours, relating to the use of electrical apparatus |
AS/NZS 4360:2004 | Risk management |
AS/NZS 60079.14:2009 | Explosive atmospheres Electrical installations design, selection and erection (IEC 60079-14, Ed. 4.0 (2007) MOD) |
AS/NZS 61241.10:2005 | Electrical apparatus for use in the presence of combustible dust Classification of areas where combustible dusts are or may be present |
AS/NZS 60079.15:2006 | Electrical apparatus for explosive gas atmospheres Construction, test and marking of type of protection, n electrical apparatus |
AS/NZS 60079.2:2007 | Explosive atmospheres Equipment protection by pressurized enclosure 'p' |
AS 2380.4-1994 | Electrical equipment for explosive atmospheres - Explosion-protection techniques Pressurized rooms or pressurized enclosures (Reconfirmed 2013) |
AS/NZS 60079.7:2006 | Explosive atmospheres Equipment protection by increased safety 'e' |
AS/NZS 61241.4:2002 | Electrical apparatus for use in the presence of combustible dust Type of protection 'pD' |
AS/NZS 60079.27:2008 | Explosive atmospheres Fieldbus intrinsically safe concept (FISCO) |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 61241.1:2005 | Electrical apparatus for use in the presence of combustible dust Protection by enclosures 'tD' |
AS/NZS 60079.29.2:2008 | Explosive atmospheres Gas detectors - Selection, installation, use and maintenance of detectors for flammable gases and oxygen |
AS/NZS 60079.25:2004 | Electrical apparatus for explosive gas atmospheres Intrinsically safe systems |
AS/NZS 60079.28:2007 | Explosive atmospheres Protection of equipment and transmission systems using optical radiation |
AS/NZS 61241.11:2006 | Electrical apparatus for use in the presence of combustible dust Protection by intrinsic safety iD |
AS/NZS 61241.14:2005 | Electrical apparatus for use in the presence of combustible dust Selection and installation (IEC 61241-14, Ed.1.0(2004) MOD) |
AS/NZS 60079.10.1:2009 | Explosive atmospheres Classification of areas - Explosive gas atmospheres (IEC 60079-10-1, Ed.1.0(2008) MOD) |
AS/NZS 4761.2:2008 | Competencies for working with electrical equipment for hazardous areas (EEHA) Guide to assessing competency |
AS/NZS 4761.1:2008 | Competencies for working with electrical equipment for hazardous areas (EEHA) Competency Standards |
AS/NZS 60079.1:2007 | Explosive atmospheres Equipment protection by flameproof enclosures 'd' |
AS/NZS 60079.11:2006 | Explosive atmospheres Equipment protection by intrinsic safety 'i' |
AS/NZS 60079.0:2008 | Explosive atmospheres Equipment - General requirements |
AS/NZS 3800:2005 | Electrical equipment for explosive atmospheres - Repair and overhaul |
AS 1482-1985 | Electrical equipment for explosive atmospheres - Protection by ventilation - Type of protection v (Reconfirmed 2013) |
AS/NZS 60079.29.1:2008 | Explosive atmospheres Gas detectors - Performance requirements of detectors for flammable gases |
AS 4647-2011 | Diaphragm gas meters |
AS/NZS 1716:2012 | Respiratory protective devices (Reconfirmed 2024) |
AS/NZS 3010:2017 | Electrical installations - Generating sets |
AS/NZS 4836:2011 | Safe working on or near low-voltage electrical installations and equipment |
AS/NZS 60079.33:2012 | Explosive atmospheres Equipment protection by special protection 's' (Reconfirmed 2024) |
AS/NZS 2081:2011 | Electrical protection devices for mines and quarries (Reconfirmed 2022) |
AS/NZS 4745:2012 | Code of practice for handling combustible dusts |
HB 239:2011 | Guidance on the repair and overhaul of electrical equipment for explosive atmospheres |
AS 5092-2009 | CNG refuelling stations |
AS/NZS 5026:2012 | The storage and handling of Class 4 dangerous goods (Reconfirmed 2024) |
AS/NZS 1680.2.4:2017 | Interior and workplace lighting Industrial tasks and processes |
AS/NZS 60079.15:2011 | Explosive atmospheres Equipment protection by type of protection 'n' |
AS ISO 21789:2014 | Gas turbine applications - Safety |
AS/NZS 4871.3:2010 | Electrical equipment for mines and quarries Substations |
AS/NZS 3007:2013 | Electrical equipment in mines and quarries - Surface installations and associated processing plant |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.