AS/NZS 61459:2000
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Low-voltage fuses - Coordination between fuses and contactors/motor-starters - Application guide
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
30-06-2017
English
06-12-2000
Provides guidance to assist in selecting a fuse-link to ensure coordination with contactors or motor-starters (contactors with overload relay). This Standard is identical with and is reproduced from IEC 61459:1996.
Committee |
EL-007
|
DocumentType |
Standard
|
ISBN |
0 7337 3486 3
|
Pages |
14
|
ProductNote |
This standard remains current in New Zealand.
|
PublisherName |
Standards Australia
|
Status |
Withdrawn
|
Supersedes |
The information given in this technical report provides guidance to assist in selecting a fuse-link to ensure coordination with contactors or motor-starters (contactors with overload relay). The coordination between motor-starters and the fuses which protect them is covered in IEC standards by test requirements such as those in IEC 60947, in particular parts 1 and 4. Overcurrent protection of other equipment, such as motors, conductors, etc., is not covered by this technical report. Tests are specified at three levels of prospective current, according to IEC 60947-4-1: a) in the region of the current Ic (see clause 5). Tests are made at 0,75Ic when thestarter shall disconnect the current without damage and the fuse does not operate, and at 1,25 Ic when the fuse shall operate before the starter (see annex A, figure A.1); b) at the appropriate value of prospective current "r" shown in IEC 60947-4-1, table XI (see table A.1 in annex A); c) at the rated conditional short-circuit current Iq, if higher than the test current "r".The fuse selected is capable of absorbing the surge of current on starting the motor and is normally selected from the recommendations of the manufacturer or by compliance with national installation codes and wiring rules. Studies carried out by IEC committee "Fuses" in collaboration with motor-starter manufacturers worldwide have revealed that there is no major difficulty in achieving satisfactory coordination at the most exacting of the levels of type of coordination using selected fuses according to IEC 60269-2 in coordination with modern contactors. A survey is presented in annex B of the rated currents, I²t values and cut-off currents of fuses correctly chosen according to the ratings of the starters they protect, based on the results of successful type testing throughout the world. Examples of suitable fuse-links used for motor protection are also given in annex B.
First published as AS/NZS 61459:2000.
AS/NZS 60269.2.0:2000 | Low-voltage fuses Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) |
AS 3947.4.1-1995 | Low-voltage switchgear and controlgear Contactors and motor-starters - Electromechanical contactors and motor-starters |
AS/NZS 3947.1:1998 | Low-voltage switchgear and controlgear General rules |
AS 1852.441-1985 | International electrotechnical vocabulary - Switchgear, controlgear and fuses |
AS 61818-2005 | Application guide for low-voltage fuses |