AS/RISSB 7722 : 2016
Current
The latest, up-to-date edition.
EMC Management
English
01-01-2016
The purpose of this standard is to define requirements for the management of electromagnetic emissions and susceptibility of devices used in the railway so that all systems used in the railway are electromagnetically compatible.These requirements define the minimum effort required to manage the risk associated with EMC and to ensure compliance with legal and regulatory, safety and reliability requirements; particular situations may require more detailed assessment.The scope of this document covers requirements for the management of EMC as applicable to:- a) Planning EMC management- b) Introduction of new rail assets (new products or integrated systems) - c) Alterations to existing rail assets (existing products or integrated systems)- d) Novel alterations to existing rail system configurations or layouts- e) Maintenance of operational rail systems- f) Decommissioning of rail systemsThe scope of this standard is limited to rail systems and assets under the scope and control of the Australian railway networks.
DocumentType |
Standard
|
Pages |
27
|
PublisherName |
Rail Industry Safety and Standards Board
|
Status |
Current
|
First published as AS/RISSB 7722:2016.
AS/NZS 61000.6.3:2012 | Electromagnetic compatibility (EMC) Generic standards - Emission standard for residential, commercial and light-industrial environments |
IEC 61000-6-7:2014 | Electromagnetic compatibility (EMC) - Part 6-7: Generic standards - Immunity requirements for equipment intended to perform functions in a safety-related system (functional safety) in industrial locations |
AS/NZS 1768:2007 | Lightning protection |
IEC 61133:2016 | Railway applications - Rolling stock - Testing of rolling stock on completion of construction and before entry into service |
AS/NZS 7000:2016 | Overhead line design |
EN 50121-3-2:2016 | Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus |
IEC TS 61000-1-2:2008 | Electromagnetic compatibility (EMC) - Part 1-2: General - Methodology for the achievement of functional safety of electrical and electronic systems including equipment with regard to electromagnetic phenomena |
EN 50121-1:2017 | Railway applications - Electromagnetic compatibility - Part 1: General |
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV | Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control |
AS/NZS 61000.6.2:2006 | Electromagnetic compatibility (EMC) General standards - Immunity for industrial environments (Reconfirmed 2016) |
AS/RISSB 7505 : 2014 | Railway Rolling Stock – Signal Detection Interface Signalling Detection Interface |
AS/NZS 61000.6.1:2006 | Electromagnetic compatibility (EMC) Generic standards - Immunity for residential, commercial and light industrial environments (Reconfirmed 2016) |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
EN 55022:2010/AC:2011 | INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008) |
IEC 60364-4-44:2007+AMD1:2015 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
EN 50121-3-1:2017 | Railway applications - Electromagnetic compatibility - Part 3-1: Rolling stock - Train and complete vehicle |
IEC 60571:2012 | Railway applications - Electronic equipment used on rolling stock |
EN 50121-4:2016 | Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus |
EN 50121-2:2017 | Railway applications - Electromagnetic compatibility - Part 2: Emission of the whole railway system to the outside world |
EN 50121-5:2017 | Railway applications - Electromagnetic compatibility - Part 5: Emission and immunity of fixed power supply installations and apparatus |
AS 2067:2016 | Substations and high voltage installations exceeding 1 kV a.c. |
IEC 62305-4:2010 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
CLC/TR 50427:2004 | Assessment of inadvertent ignition of flammable atmospheres by radio-frequency radiation - Guide |
AS/NZS 61000.6.4:2012 | Electromagnetic compatibility (EMC) Generic standards - Emission standard for industrial environments |
EN 50238-1 : 2003 COR 2014 | RAILWAY APPLICATIONS - COMPATIBILITY BETWEEN ROLLING STOCK AND TRAIN DETECTION SYSTEMS - PART 1: GENERAL |
AS 2344:2016 | Limits of electromagnetic interference from overhead a.c. powerlines and high voltage equipment installations in the frequency range 0.15 MHz to 3000 MHz |
IEC TR 61000-5-1:1996 | Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 1: General considerations - Basic EMC publication |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.