ASTM C 165 : 2007 : R2017
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Measuring Compressive Properties of Thermal Insulations
Hardcopy , PDF
20-03-2023
English
13-12-2017
CONTAINED IN VOL. 04.06, 2017 Provides two procedures for determining the compressive resistance of thermal insulations.
Committee |
C 16
|
DocumentType |
Test Method
|
Pages |
5
|
ProductNote |
Reconfirmed 2017
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This test method covers two procedures for determining the compressive resistance of thermal insulations.
1.1.1Procedure A covers thermal insulations having an approximate straight-line portion of a load-deformation curve, with or without an identifiable yield point as shown in Figs. 1 and 2. Such behavior is typical of most rigid board or block-type insulations.
FIG. 1Procedure A—Straight Line Portion with Definite Yield Point
FIG. 2Procedure A—Straight Line Portion but no Definite Yield Point
1.1.2Procedure B covers thermal insulations that become increasingly more stiff as load is increased, as shown in Fig. 3. Such behavior is typical of fibrous batt and blanket insulations that have been compressed previously to at least the same deformation by compression packaging or mechanical softening.
FIG. 3Procedure B—Increasing Stiffness
1.2It is recognized that the classification of materials under Procedures A and B shall not hold in all cases. For example, some batt or blanket materials that have not been compression packaged will exhibit behavior more typical of Procedure A for their first loadings. Also, some higher density fibrous insulation boards that have been precompressed will exhibit load-deformation curves more typical of Procedure B. There will also be thermal insulations with load-deformation curves that follow none of the three types shown here; that is, curves with no straight-line portion, curves with compaction areas, and curves that change from negative to positive slope.
1.3This test method does not cover reflective or loose fill insulations.
1.4The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM C 1728 : 2022 | Standard Specification for Flexible Aerogel Insulation |
ASTM C 1423 : 2021 | Standard Guide for Selecting Jacketing Materials for Thermal Insulation |
ASTM D 6817/D6817M : 2017 : R2021 | Standard Specification for Rigid Cellular Polystyrene Geofoam |
ASTM C 1484 : 2010 : R2018 | Standard Specification for Vacuum Insulation Panels |
ASTM C 656 : 2017 | Standard Specification for Structural Insulating Board, Calcium Silicate |
ASTM C 533 : 2017 | Standard Specification for Calcium Silicate Block and Pipe Thermal Insulation |
ASTM C 208 : 2022 | Standard Specification for Cellulosic Fiber Insulating Board |
ASTM C 726 : 2017 | Standard Specification for Mineral Wool Roof Insulation Board |
ASTM C 1676/C1676M : 2019 | Standard Specification for Microporous Thermal Insulation |
ASTM C 1482 : 2017 | Standard Specification for Polyimide Flexible Cellular Thermal and Sound Absorbing Insulation |
ASTM C 1126 : 2019 | Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation |
ASTM C 610 : 2017 | Standard Specification for Molded Expanded Perlite Block and Pipe Thermal Insulation |
ASTM C 209 : 2020 | Standard Test Methods for Cellulosic Fiber Insulating Board |
ASTM C 591 : 2022 | Standard Specification for Unfaced Preformed Rigid Cellular Polyisocyanurate Thermal Insulation |
ASTM C 728 : 2017 : REV A : R2022 | Standard Specification for Perlite Thermal Insulation Board |
ASTM D 7425/D7425M : 2013 : R2019 | Standard Specification for Spray Polyurethane Foam Used for Roofing Applications |
ASTM C 1685 : 2015 : R2021 | Standard Specification for Pneumatically Applied High-Temperature Fiber Thermal Insulation for Industrial Applications |
ASTM C 1029 : 2020 | Standard Specification for Spray-Applied Rigid Cellular Polyurethane Thermal Insulation |
ASTM C 1696 : 2020 | Standard Guide for Industrial Thermal Insulation Systems |
ASTM C 1902 : 2022 : REV A | Standard Specification for Cellular Glass Insulation Used in Building and Roof Applications |
ASTM F 3319 : 2020 | Standard Specification for Selection and Application of Field-Installed Cryogenic Pipe and Equipment Insulation Systems on Liquefied Natural Gas (LNG)-Fueled Ships |
ASTM C 447 : 2015 : R2022 | Standard Practice for Estimating the Maximum Use Temperature of Thermal Insulations |
ASTM D 7492/D7492M : 2016 : REV A | Standard Guide for Use of Drainage System Media with Waterproofing Systems |
ASTM C 612 : 2014(R2019) | Standard Specification for Mineral Fiber Block and Board Thermal Insulation |
ASTM C 552 : 2022 | Standard Specification for Cellular Glass Thermal Insulation |
ASTM C 578 : 2022 | Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation |
ASTM C 1393 : 2019 | Standard Specification for Perpendicularly Oriented Mineral Fiber Roll and Sheet Thermal Insulation for Pipes and Tanks |
ASTM C 168 : 2019 | Standard Terminology Relating to Thermal Insulation |
ASTM E 177 : 1990 : REV A : R1996 | Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods |
ASTM E 177 : 2014 : REDLINE | Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods |
ASTM E 691 : 2020 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM C 240 : 2020 | Standard Test Methods for Testing Cellular Glass Insulation Block |
ASTM E 691 : 2019 : EDT 1 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM C 167 : 2022 | Standard Test Methods for Thickness and Density of Blanket or Batt Thermal Insulations |
ASTM C 240 : 2021 | Standard Test Methods for Testing Cellular Glass Insulation Block |
ASTM E 691 : 2022 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM E 691 : 2009 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM E 4 : 2021 | Standard Practices for Force Calibration and Verification of Testing Machines |
ASTM E 691 : 2021 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM C 167 : 2018 | Standard Test Methods for Thickness and Density of Blanket or Batt Thermal Insulations |
ASTM C 167 : 1998 | Standard Test Methods for Thickness and Density of Blanket or Batt Thermal Insulations |
ASTM C 168 : 2022 | Standard Terminology Relating to Thermal Insulation |
ASTM C 168 : 2017-06 | TERMINOLOGY RELATING TO THERMAL INSULATION |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.