1.1These test methods cover procedures for testing crosslinked insulations and jackets for wire and cable. To determine the test to be made on the particular insulation or jacket, refer to the product specification for that type. These test methods do not apply to the class of products known as flexible cords.
1.2In many instances the insulation or jacket cannot be tested unless it has been formed around a conductor or cable. Therefore, tests are done on insulated or jacketed wire or cable in these test methods solely to determine the relevant property of the insulation or jacket and not to test the conductor or completed cable.
1.3These test methods appear in the following sections:
Test Method | Section(s) |
AC and DC Voltage Withstand Tests | 22 to 29 |
Capacitance and Dissipation Factor Tests | 38 to 44 |
Cold Bend | 124 |
Cold Bend, Long-time Voltage Test on Short Specimens | 51 to 57 |
Double AC Voltage Test on Short Specimens | 45 to 50 |
Electrical Tests of Insulation | 17 to 64 |
Heat Distortion Test | 123 |
Horizontal Flame Test | 100 |
Insulation Resistance Tests on Completed Cable | 30 to 37 |
Mineral Filler Content, Determination of | 107 to 111 |
Ozone Resistance Test | 87 to 99 |
Partial-Discharge Test | 58 to 64 |
Physical Tests of Insulation and Jacket Compounds | 5 to 16 |
Surface Resistivity Test | 112 to 116 |
Track Resistance Test | 125 to 128 |
U-Bend Discharge Test | 117 to 121 |
Water Absorption Test | 65 to 71 |
Water Absorption Test, Accelerated | 72 to 86 |
Water Absorption Test on Fibrous Coverings | 101 to 106 |
1.4Whenever two sets of values are presented, in different units, the values in the first set are the standard, while those in the parentheses are for information only.
1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazards see Section 4.
1.6This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM D 4325 : 2020 | Standard Test Methods for Nonmetallic Semi-Conducting and Electrically Insulating Rubber Tapes |
ASTM D 4313 : 2017 | Standard Specification for General-Purpose, Heavy-Duty, and Extra-Heavy-Duty Crosslinked Chlorinated Polyethylene (CM) Jackets For Wire and Cable |
ASTM D 2655 : 2019 | Standard Specification for Crosslinked Polyethylene Insulation for Wire and Cable Rated 0 to 2000 V, 90°C Operation |
ASTM D 7936 : 2020 | Standard Test Method for Flammability of Electrical Insulating Materials Intended for Wires or Cables When Burning in Horizontal Configuration |
ASTM D 1711 : 2020 | Standard Terminology Relating to Electrical Insulation |
ASTM D 3555 : 2020 : EDT 1 | Standard Specification for Track-Resistant Crosslinked Polyethylene Insulation for Wire and Cable, 90 °C Operation |
ASTM D 2656 : 2020 | Standard Specification for Crosslinked Polyethylene Insulation for Wire and<brk/> Cable Rated 2001 to 35 000 V |
ASTM F 855 : 2020 | Standard Specifications for Temporary Protective Grounds to Be Used on De-energized Electric Power Lines and Equipment |
ASTM D 4246 : 2014 : R2020 | Standard Specification for Ozone-Resistant Thermoplastic Elastomer Insulation for Wire and Cable, 90°C Operation |
ASTM D 150 : 2022 | Standard Test Methods for AC Loss Characteristics and Permittivity (Dielectric Constant) of Solid Electrical Insulation |
ASTM D 2132 : 2023 | Standard Test Method for Dust-and-Fog Tracking and Erosion Resistance of Electrical Insulating Materials |
ASTM D 5423 : 2022 | Standard Specification for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation |
ASTM D 257 : 2014 | Standard Test Methods for DC Resistance or Conductance of Insulating Materials |
ASTM D 412 : 2016 : EDT 1 | Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension |
ASTM D 1711 : 2024 : REV A | Standard Terminology Relating to Electrical Insulation |
ASTM D 572 : 2023 | Standard Test Method for Rubber—Deterioration by Heat and Oxygen |
ASTM D 5423 : 2023 | Standard Specification for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation |
ASTM D 412 : 2016 | Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension |
ASTM D 1711 : 2024 | Standard Terminology Relating to Electrical Insulation |
ASTM D 2132 : 2019 | Standard Test Method for Dust-and-Fog Tracking and Erosion Resistance of Electrical Insulating Materials |
ASTM D 1711 : 2022 | Standard Terminology Relating to Electrical Insulation |
ASTM D 412 : 2016 : R2021 | Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension |
ASTM D 150 : 2018 | Standard Test Methods for AC Loss Characteristics and Permittivity (Dielectric Constant) of Solid Electrical Insulation |
ASTM D 2132 : 1998 | Standard Test Method for Dust-and-Fog Tracking and Erosion Resistance of Electrical Insulating Materials |
ASTM D 572 : 2004 : R2019 | Standard Test Method for Rubber—Deterioration by Heat and Oxygen |
ASTM D 257 : 2014 : R2021 : EDT 1 | Standard Test Methods for DC Resistance or Conductance of Insulating Materials |
ASTM D 5423 : 2014 | Standard Specification for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-