• Shopping Cart
    There are no items in your cart

ASTM D 5222 : 2016 : REDLINE

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Specification for High Fire-Point Mineral Electrical Insulating Oils

Available format(s)

PDF

Superseded date

15-03-2023

Language(s)

English

Published date

30-11-2016

€59.22
Excluding VAT

CONTAINED IN VOL. 10.03, 2016 Specifies a high fire-point mineral oil based insulating fluid, for use as a dielectric and cooling medium in new and existing power and distribution electrical apparatus, such as transformers and switchgear.

Committee
D 27
DocumentType
Redline
Pages
3
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1This specification describes a high fire-point mineral oil based insulating fluid, for use as a dielectric and cooling medium in new and existing power and distribution electrical apparatus, such as transformers and switchgear.

1.2High fire-point insulating oil differs from conventional mineral insulating oil by possessing a fire-point of at least 300°C. High fire-point mineral insulating oils are also referred to as “less flammable” mineral insulating oils.This property is necessary in order to comply with certain application requirements of the National Electrical Code (Article 450-23) or other agencies. The material discussed in this specification is miscible with other petroleum based insulating oils. Mixing high fire-point liquids with lower fire point hydrocarbon insulating oils (for example, Specification D3487 mineral oil) may result in fire points of less than 300°C.

1.3This specification is intended to define a high fire-point electrical mineral insulating oil that is compatible with typical material of construction of existing apparatus and will satisfactorily maintain its functional characteristic in its application in this application. The material described in this specification may not be miscible with electrical insulating liquids of non-petroleum origin. The user should contact the manufacturer of the high fire-point insulating oil for guidance in this respect.

1.4This specification applies only to new insulating material oil as received prior to any processing. Information on in-service maintenance testing is available in appropriate guides.2 The user should contact the manufacturers of the equipment or oil if questions of recommended characteristics or maintenance procedures arise.

1.5The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

IEEE DRAFT C57.93 : D13 2005 INSTALLATION AND MAINTENANCE OF LIQUID-IMMERSED POWER TRANSFORMERS
IEEE C57.637-2015 IEEE Guide for the Reclamation of Mineral Insulating Oil and Criteria for Its Use
ASTM D 3635 : 2013 : REDLINE Standard Test Method for Dissolved Copper In Electrical Insulating Oil By Atomic Absorption Spectrophotometry
IEEE DRAFT C57.121 : D4 OCT 96 DRAFT GUIDE FOR ACCEPTANCE AND MAINTENANCE OF LESS-FLAMMABLE HYDROCARBON FLUID IN TRANSFORMERS
ASTM D 6813 : 2002 : REV A : R2007 Standard Guide for Performance Evaluation of Hydraulic Fluids for Piston Pumps
ASTM D 6813 : 2002 Standard Guide for Performance Evaluation of Hydraulic Fluids for Piston Pumps
ASTM D 6813 : 2002 : REV A : R2013 Standard Guide for Performance Evaluation of Hydraulic Fluids for Piston Pumps (Withdrawn 2015)
ASTM D 6813 : 2002 : REV A Standard Guide for Performance Evaluation of Hydraulic Fluids for Piston Pumps
ASTM D 4768 : 2011 : REDLINE Standard Test Method for Analysis of 2,6-Ditertiary-Butyl Para-Cresol and 2,6-Ditertiary-Butyl Phenol in Insulating Liquids by Gas Chromatography
IEEE C57.91-2011 REDLINE IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators
IEEE 979-2012 IEEE Guide for Substation Fire Protection
IEEE C57.12.00-2015 IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
IEEE C57.93-2007 IEEE Guide for Installation and Maintenance of Liquid-Immersed Power Transformers
ISA 12.26.01 : 1998 ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS: TYPE OF PROTECTION - OIL IMMERSION "O"
ASTM D 877/D877M : 2013 : REDLINE Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes

ASTM D 1816 : 2012 : REDLINE Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using VDE Electrodes
ASTM D 924 : 2015 : REDLINE Standard Test Method for Dissipation Factor (or Power Factor) and Relative Permittivity (Dielectric Constant) of Electrical Insulating Liquids
ASTM D 5950 : 2014 : REDLINE Standard Test Method for Pour Point of Petroleum Products (Automatic Tilt Method)
ASTM D 1275 : 2015 Standard Test Method for Corrosive Sulfur in Electrical Insulating Liquids
ASTM D 1533 : 2012 : REDLINE Standard Test Method for Water in Insulating Liquids by Coulometric Karl Fischer Titration
ASTM D 2440 : 2013 : REDLINE Standard Test Method for Oxidation Stability of Mineral Insulating Oil
ASTM D 5949 : 2016 : REDLINE Standard Test Method for Pour Point of Petroleum Products (Automatic Pressure Pulsing Method)
ASTM D 1524 : 2015 : REDLINE Standard Test Method for Visual Examination of Used Electrical Insulating Liquids in the Field
ASTM D 4768 : 2011 : REDLINE Standard Test Method for Analysis of 2,6-Ditertiary-Butyl Para-Cresol and 2,6-Ditertiary-Butyl Phenol in Insulating Liquids by Gas Chromatography
ASTM D 923 : 2015 : REDLINE Standard Practices for Sampling Electrical Insulating Liquids
ASTM D 2112 : 2015 : REDLINE Standard Test Method for Oxidation Stability of Inhibited Mineral Insulating Oil by Pressure Vessel

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.