• ASTM D 5222 : 2016 : REDLINE

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Standard Specification for High Fire-Point Mineral Electrical Insulating Oils

    Available format(s):  PDF

    Superseded date:  15-03-2023

    Language(s):  English

    Published date:  30-11-2016

    Publisher:  American Society for Testing and Materials

    Add To Cart

    Abstract - (Show below) - (Hide below)

    CONTAINED IN VOL. 10.03, 2016 Specifies a high fire-point mineral oil based insulating fluid, for use as a dielectric and cooling medium in new and existing power and distribution electrical apparatus, such as transformers and switchgear.

    Scope - (Show below) - (Hide below)

    1.1This specification describes a high fire-point mineral oil based insulating fluid, for use as a dielectric and cooling medium in new and existing power and distribution electrical apparatus, such as transformers and switchgear.

    1.2High fire-point insulating oil differs from conventional mineral insulating oil by possessing a fire-point of at least 300°C. High fire-point mineral insulating oils are also referred to as “less flammable” mineral insulating oils.This property is necessary in order to comply with certain application requirements of the National Electrical Code (Article 450-23) or other agencies. The material discussed in this specification is miscible with other petroleum based insulating oils. Mixing high fire-point liquids with lower fire point hydrocarbon insulating oils (for example, Specification D3487 mineral oil) may result in fire points of less than 300°C.

    1.3This specification is intended to define a high fire-point electrical mineral insulating oil that is compatible with typical material of construction of existing apparatus and will satisfactorily maintain its functional characteristic in its application in this application. The material described in this specification may not be miscible with electrical insulating liquids of non-petroleum origin. The user should contact the manufacturer of the high fire-point insulating oil for guidance in this respect.

    1.4This specification applies only to new insulating material oil as received prior to any processing. Information on in-service maintenance testing is available in appropriate guides.2 The user should contact the manufacturers of the equipment or oil if questions of recommended characteristics or maintenance procedures arise.

    1.5The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

    General Product Information - (Show below) - (Hide below)

    Committee D 27
    Document Type Redline
    Publisher American Society for Testing and Materials
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    IEEE DRAFT C57.93 : D13 2005 INSTALLATION AND MAINTENANCE OF LIQUID-IMMERSED POWER TRANSFORMERS
    IEEE C57.637-2015 REDLINE IEEE Guide for the Reclamation of Mineral Insulating Oil and Criteria for Its Use
    ASTM D 3635 : 2013 : REDLINE Standard Test Method for Dissolved Copper In Electrical Insulating Oil By Atomic Absorption Spectrophotometry
    IEEE DRAFT C57.121 : D4 OCT 96 DRAFT GUIDE FOR ACCEPTANCE AND MAINTENANCE OF LESS-FLAMMABLE HYDROCARBON FLUID IN TRANSFORMERS
    ASTM D 6813 : 2002 : REV A : R2007 Standard Guide for Performance Evaluation of Hydraulic Fluids for Piston Pumps
    ASTM D 6813 : 2002 Standard Guide for Performance Evaluation of Hydraulic Fluids for Piston Pumps
    ASTM D 6813 : 2002 : REV A : R2013 Standard Guide for Performance Evaluation of Hydraulic Fluids for Piston Pumps (Withdrawn 2015)
    ASTM D 6813 : 2002 : REV A Standard Guide for Performance Evaluation of Hydraulic Fluids for Piston Pumps
    ASTM D 4768 : 2011 : REDLINE Standard Test Method for Analysis of 2,6-Ditertiary-Butyl Para-Cresol and 2,6-Ditertiary-Butyl Phenol in Insulating Liquids by Gas Chromatography
    IEEE C57.91-2011 REDLINE IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators
    IEEE 979-2012 IEEE Guide for Substation Fire Protection
    IEEE C57.12.00-2015 IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
    IEEE C57.93-2007 IEEE Guide for Installation and Maintenance of Liquid-Immersed Power Transformers
    ISA 12.26.01 : 1998 ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS: TYPE OF PROTECTION - OIL IMMERSION "O"
    ASTM D 877/D877M : 2013 : REDLINE Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes

    Standards Referencing This Book - (Show below) - (Hide below)

    ASTM D 1816 : 2012 : REDLINE Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using VDE Electrodes
    ASTM D 924 : 2015 : REDLINE Standard Test Method for Dissipation Factor (or Power Factor) and Relative Permittivity (Dielectric Constant) of Electrical Insulating Liquids
    ASTM D 5950 : 2014 : REDLINE Standard Test Method for Pour Point of Petroleum Products (Automatic Tilt Method)
    ASTM D 1275 : 2015 Standard Test Method for Corrosive Sulfur in Electrical Insulating Liquids
    ASTM D 1533 : 2012 : REDLINE Standard Test Method for Water in Insulating Liquids by Coulometric Karl Fischer Titration
    ASTM D 2440 : 2013 : REDLINE Standard Test Method for Oxidation Stability of Mineral Insulating Oil
    ASTM D 5949 : 2016 : REDLINE Standard Test Method for Pour Point of Petroleum Products (Automatic Pressure Pulsing Method)
    ASTM D 1524 : 2015 : REDLINE Standard Test Method for Visual Examination of Used Electrical Insulating Liquids in the Field
    ASTM D 4768 : 2011 : REDLINE Standard Test Method for Analysis of 2,6-Ditertiary-Butyl Para-Cresol and 2,6-Ditertiary-Butyl Phenol in Insulating Liquids by Gas Chromatography
    ASTM D 923 : 2015 : REDLINE Standard Practices for Sampling Electrical Insulating Liquids
    ASTM D 2112 : 2015 : REDLINE Standard Test Method for Oxidation Stability of Inhibited Mineral Insulating Oil by Pressure Vessel
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective