• Shopping Cart
    There are no items in your cart

ASTM D 7315 : 2007

NA

NA

Status of Standard is Unknown

Standard Test Method for Determination of Turbidity Above 1 Turbidity Unit (TU) in Static Mode

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

15-04-2007

€96.91
Excluding VAT

Committee
D 19
DocumentType
Test Method
Pages
21
PublisherName
American Society for Testing and Materials
Status
NA
SupersededBy

1.1 This test method covers the static determination of turbidity in water. Static refers to a sample that is removed from its source and tested in an isolated instrument. (See Section 4.)

1.2 This test method is applicable to the measurement of turbidities greater than 1.0 turbidity unit (TU). The upper end of the measurement range was left undefined because different technologies described in this test method can cover very different ranges. The round robin study covered the range of 0-4000 turbidity units because instrument verification in this range can typically be covered by standards that can be consistently reproduced.

1.3 Many of the turbidity units and instrument designs covered in this test method are numerically equivalent in calibration when a common calibration standard is applied across those designs listed in Table 1. Measurement of a common calibration standard of a defined value will also produce equivalent results across these technologies.

1.3.1 In this test method calibration standards are often defined in NTU values, but the other assigned turbidity units, such as those in Table 1 are equivalent. For example, a 1 NTU formazin standard is also a 1 FNU, a 1 FAU, a 1 BU, and so forth.

1.4 This test method does not purport to cover all available technologies for high-level turbidity measurement.

1.5 This test method was tested on different natural waters and wastewater, and with standards that will serve as surrogates to samples. It is the user's responsibility to ensure the validity of this test method for waters of untested matrices.

1.6 Depending on the constituents within a high-level sample, the proposed sample preparation and measurement methods may or may not be applicable. Those samples with the highest particle densities typically prove to be the most difficult to measure. In these cases, and alternative measurement method such as the process monitoring method can be considered.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Refer to the MSDSs for all chemicals used in this procedure.

ASTM D 7726 : 2011 : R2016 : EDT 1 Standard Guide for The Use of Various Turbidimeter Technologies for Measurement of Turbidity in Water
ASTM D 7512 : 2009 : R2015 Standard Guide for Monitoring of Suspended-Sediment Concentration in Open Channel Flow Using Optical Instrumentation
ASTM D 2035 : 2019 Standard Practice for Coagulation-Flocculation Jar Test of Water
ASTM D 6855 : 2017 Standard Test Method for Determination of Turbidity Below 5 NTU in Static Mode
ASTM D 8006 : 2016 Standard Guide for Sampling and Analysis of Residential and Commercial Water Supply Wells in Areas of Exploration and Production (E&P) Operations
ASTM D 4188 : 2017 Standard Practice for Performing Pressure In-Line Coagulation-Flocculation-Filtration Test in Water
ASTM D 6698 : 2014 Standard Test Method for On-Line Measurement of Turbidity Below 5 NTU in Water (Withdrawn 2023)
ASTM D 7937 : 2015 Standard Test Method for In-situ Determination of Turbidity Above 1 Turbidity Unit (TU) in Surface Water
ASTM D 7725 : 2017 Standard Test Method for the Continuous Measurement of Turbidity Above 1 Turbidity Unit (TU)

Access your standards online with a subscription