ASTM D 7911 : 2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Guide for Using Reference Material to Characterize Measurement Bias Associated with Volatile Organic Compound Emission Chamber Test
Hardcopy , PDF
13-01-2020
English
01-09-2014
CONTAINED IN VOL. 11.07, 2014 Gives procedures for using a reference material with a known emission rate of a volatile organic compound (VOC) to estimate the bias associated with a VOC emission chamber test.
Committee |
D 22
|
DocumentType |
Guide
|
Pages |
9
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1This guide provides procedures for using a reference material with a known emission rate of a volatile organic compound (VOC) to estimate the bias associated with a VOC emission chamber test.
1.2This guide may be used to assess measurements of VOC emissions conducted in a variety of environmental chambers, such as small-scale chambers, full-scale chambers, emission cells, and micro-scale chambers.
1.3This guide may be used to assess measurements of VOC emissions from a variety of sources including “dry” materials (for example, carpet, floor tile and particleboard) and “wet” materials (for example, paint and cleaning products).
1.4This guide can be used to support quality control efforts by emissions testing laboratories, third party accreditation of testing laboratories participating in emissions testing programs, and quality control efforts by manufacturers of building and other materials.
1.5This guide may be used to support the determination of precision and bias of other commonly used VOC emission standards including Guide D5116, Test Method D6007, ISO 16000-9, ANSI/BIFMA M7.1, and CDPH/EHLB/Standard Method V1.1.
1.6This guide also describes the attributes of a suitable emission reference material and the different methods available to independently determine the reference material’s VOC emission rate.
1.7The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.8This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM D 5116 : 2017 | Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/Products |
ASTM D 5116 : 2017 : REDLINE | Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/Products |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
ASTM E 1333 : 2010 | Standard Test Method for Determining Formaldehyde Concentrations in Air and Emission Rates from Wood Products Using a Large Chamber |
ASTM D 6299 : 2010 | Standard Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measurement System Performance |
ASTM D 6299 : 2013 : EDT 1 | Standard Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measurement System Performance |
ASTM D 7706 : 2017 : REDLINE | Standard Practice for Rapid Screening of VOC Emissions from Products Using Micro-Scale Chambers |
ASTM D 5466 : 1995 | Standard Test Method for Determination of Volatile Organic Chemicals in Atmospheres (Canister Sampling Methodology) |
ASTM D 7339 : 2007 | Standard Test Method for Determination of Volatile Organic Compounds Emitted from Carpet using a Specific Sorbent Tube and Thermal Desorption / Gas Chromatography |
ASTM D 6299 : 2017 : REV A | Standard Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measurement System Performance |
ASTM D 7339 : 2018 | Standard Test Method for Determination of Volatile Organic Compounds Emitted from Carpet using a Specific Sorbent Tube and Thermal Desorption / Gas Chromatography |
ASTM D 6299 : 2017 : REV B | Standard Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measurement System Performance |
ASTM E 1333 : 2014 | Standard Test Method for Determining Formaldehyde Concentrations in Air and Emission Rates from Wood Products Using a Large Chamber |
ASTM D 1356 : 2015 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 6299 : 2009 | Standard Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measurement System Performance |
ASTM D 6617 : 2017 : REDLINE | Standard Practice for Laboratory Bias Detection Using Single Test Result from Standard Material |
ASTM D 6803 : 2002 | Standard Practice for Testing and Sampling of Volatile Organic Compounds (Including Carbonyl Compounds) Emitted from Paint Using Small Environmental Chambers |
ASTM D 6803 : 2013 | Standard Practice for Testing and Sampling of Volatile Organic Compounds (Including Carbonyl Compounds) Emitted from Paint Using Small Environmental Chambers |
ASTM D 5466 : 2015 | Standard Test Method for Determination of Volatile Organic Compounds in Atmospheres (Canister Sampling Methodology) |
ASTM D 6330 : 1998 | Standard Practice for Determination of Volatile Organic Compounds (Excluding Formaldehyde) Emissions from Wood-Based Panels Using Small Environmental Chambers Under Defined Test Conditions |
ASTM D 6299 : 2013 | Standard Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measurement System Performance |
ASTM D 6196 : 1997 | Standard Practice for Selection of Sorbents and Pumped Sampling/Thermal Desorption Analysis Procedures for Volatile Organic Compunds in Air |
ISO/IEC Guide 98:1993 | Guide to the expression of uncertainty in measurement (GUM) |
ASTM D 5116 : 2006 | Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions From Indoor Materials/Products |
ASTM D 6299 : 2010 : EDT 1 | Standard Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measurement System Performance |
ASTM D 6330 : 1998 : R2014 | Standard Practice for Determination of Volatile Organic Compounds (Excluding Formaldehyde) Emissions from Wood-Based Panels Using Small Environmental Chambers Under Defined Test Conditions |
ASTM D 1356 : 2017 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 6617 : 2013 | Standard Practice for Laboratory Bias Detection Using Single Test Result from Standard Material |
ASTM D 6617 : 2005 | Standard Practice for Laboratory Bias Detection Using Single Test Result from Standard Material |
ASTM D 6007 : 2014 | Standard Test Method for Determining Formaldehyde Concentrations in Air from Wood Products Using a Small-Scale Chamber |
ASTM D 5466 : 2001 : R2007 | Standard Test Method for Determination of Volatile Organic Chemicals in Atmospheres (Canister Sampling Methodology) |
ASTM D 6803 : 2002 : R2007 | Standard Practice for Testing and Sampling of Volatile Organic Compounds (Including Carbonyl Compounds) Emitted from Paint Using Small Environmental Chambers |
ISO 12219-3:2012 | Interior air of road vehicles — Part 3: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials — Micro-scale chamber method |
ISO Guide 33:2015 | Reference materials — Good practice in using reference materials |
ASTM D 6196 : 2003 : R2009 | Standard Practice for Selection of Sorbents, Sampling, and Thermal Desorption Analysis Procedures for Volatile Organic Compounds in Air |
ASTM D 1356 : 2015 : REV B | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 6299 : 2000 | Standard Practice for Applying Statistical Quality Assurance Techniques to Evaluate Analytical Measurement System Performance |
ISO Guide 35:2017 | Reference materials — Guidance for characterization and assessment of homogeneity and stability |
ASTM D 6299 : 2010 : EDT 2 | Standard Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measurement System Performance |
ASTM D 5116 : 2010 | Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions From Indoor Materials/Products |
ASTM D 6299 : 2016 | Standard Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measurement System Performance |
ASTM D 7143 : 2011 : R2016 | Standard Practice for Emission Cells for the Determination of Volatile Organic Emissions from Indoor Materials/Products |
ASTM E 1333 : 1996 | Standard Test Method for Determining Formaldehyde Concentrations in Air and Emission Rates from Wood Products Using a Large Chamber |
ASTM D 6803 : 2013 : REDLINE | Standard Practice for Testing and Sampling of Volatile Organic Compounds (Including Carbonyl Compounds) Emitted from Paint Using Small Environmental Chambers |
ASTM D 6670 : 2013 | Standard Practice for Full-Scale Chamber Determination of Volatile Organic Emissions from Indoor Materials/Products |
ASTM D 6196 : 2015 : EDT 1 | Standard Practice for Choosing Sorbents, Sampling Parameters and Thermal Desorption Analytical Conditions for Monitoring Volatile Organic Chemicals in Air |
ASTM D 5466 : 2015 : REDLINE | Standard Test Method for Determination of Volatile Organic Compounds in Atmospheres (Canister Sampling Methodology) |
ASTM D 6299 : 2000 : REV A | Standard Practice for Applying Statistical Quality Assurance Techniques to Evaluate Analytical Measurement System Performance |
ASTM D 6196 : 2015 | Standard Practice for Choosing Sorbents, Sampling Parameters and Thermal Desorption Analytical Conditions for Monitoring Volatile Organic Chemicals in Air |
ASTM D 1356 : 2014 : REV A | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 6617 : 2008 | Standard Practice for Laboratory Bias Detection Using Single Test Result from Standard Material |
ASTM D 7440 : 2008 : R2015 : EDT 1 | Standard Practice for Characterizing Uncertainty in Air Quality Measurements |
ASTM D 5116 : 2017 | Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/Products |
ASTM D 7143 : 2005 | Standard Practice for Emission Cells for the Determination of Volatile Organic Emissions from Indoor Materials/Products |
ASTM D 5197 : 1997 | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ASTM D 6803 : 2019 | Standard Practice for Testing and Sampling of Volatile Organic Compounds (Including Carbonyl Compounds) Emitted from Architectural Coatings Using Small-Scale Environmental Chambers |
ISO/IEC 17043:2010 | Conformity assessment — General requirements for proficiency testing |
ISO Guide 30:2015 | Reference materials — Selected terms and definitions |
ASTM D 6299 : 2008 | Standard Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measurement System Performance |
ASTM D 6330 : 1998 : R2008 | Standard Practice for Determination of Volatile Organic Compounds (Excluding Formaldehyde) Emissions from Wood-Based Panels Using Small Environmental Chambers Under Defined Test Conditions |
ASTM D 1356 : 2015 : REV A | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ISO 16000-9:2006 | Indoor air — Part 9: Determination of the emission of volatile organic compounds from building products and furnishing — Emission test chamber method |
ASTM D 7440 : 2008 | Standard Practice for Characterizing Uncertainty in Air Quality Measurements |
ASTM D 1356 : 2005 : R2010 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM E 1333 : 2014 : REDLINE | Standard Test Method for Determining Formaldehyde Concentrations in Air and Emission Rates from Wood Products Using a Large Chamber |
ASTM D 6007 : 2002 : R2008 | Standard Test Method for Determining Formaldehyde Concentration in Air from Wood Products Using a Small Scale Chamber |
ASTM D 5197 : 2016 : REDLINE | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ASTM D 6299 : 2002 : EDT 1 | Standard Practice for Applying Statistical Quality Assurance Techniques to Evaluate Analytical Measurement System Performance |
ASTM D 6196 : 2003 | Standard Practice for Selection of Sorbents, Sampling, and Thermal Desorption Analysis Procedures for Volatile Organic Compounds in Air |
ASTM D 5197 : 2016 | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ASTM D 5197 : 2009 : EDT 1 | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ASTM D 7706 : 2017 | Standard Practice for Rapid Screening of VOC Emissions from Products Using Micro-Scale Chambers |
ASTM D 6670 : 2001 | Standard Practice for Full-Scale Chamber Determination of Volatile Organic Emissions from Indoor Materials/Products |
ASTM D 6670 : 2001 : R2007 | Standard Practice for Full-Scale Chamber Determination of Volatile Organic Emissions from Indoor Materials/Products |
ISO 16000-3:2011 | Indoor air — Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air — Active sampling method |
BIFMA M7.1 : 2011(R2016) | STANDARD TEST METHOD FOR DETERMINING VOC EMISSIONS FROM OFFICE FURNITURE SYSTEMS, COMPONENTS AND SEATING |
ASTM D 6007 : 2002 | Standard Test Method for Determining Formaldehyde Concentration in Air from Wood Products Using a Small Scale Chamber |
ASTM D 7143 : 2017 : REDLINE | Standard Practice for Emission Cells for the Determination of Volatile Organic Emissions from Indoor Materials/Products |
ASTM D 7339 : 2012 | Standard Test Method for Determination of Volatile Organic Compounds Emitted from Carpet using a Specific Sorbent Tube and Thermal Desorption / Gas Chromatography |
ASTM D 7143 : 2017 | Standard Practice for Emission Cells for the Determination of Volatile Organic Emissions from Indoor Materials/Products |
ASTM D 1356 : 2000 : REV A | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 5116 : 1997 | Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/Products (Withdrawn 2006) |
ASTM D 1356 : 2014 : REV B | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 5466 : 2001 | Standard Test Method for Determination of Volatile Organic Chemicals in Atmospheres (Canister Sampling Methodology) |
ASTM D 1356 : 2014 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ISO 16000-10:2006 | Indoor air — Part 10: Determination of the emission of volatile organic compounds from building products and furnishing — Emission test cell method |
ISO 16000-11:2006 | Indoor air — Part 11: Determination of the emission of volatile organic compounds from building products and furnishing — Sampling, storage of samples and preparation of test specimens |
ASTM D 6299 : 2007 | Standard Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measurement System Performance |
ASTM D 6670 : 2018 | Standard Practice for Full-Scale Chamber Determination of Volatile Organic Emissions from Indoor Materials/Products |
ASTM D 6299 : 2007 : EDT 1 | Standard Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measurement System Performance |
ASTM D 6330 : 1998 : R2003 | Standard Practice for Determination of Volatile Organic Compounds (Excluding Formaldehyde) Emissions from Wood-Based Panels Using Small Environmental Chambers Under Defined Test Conditions |
ASTM D 6007 : 2014 : REDLINE | Standard Test Method for Determining Formaldehyde Concentrations in Air from Wood Products Using a Small-Scale Chamber |
ASTM D 1356 : 2005 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 6299 : 2017 | Standard Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measurement System Performance |
ASTM D 6007 : 1996 | Standard Test Method for Determining Formaldehyde Concentration in Air from Wood Products Using a Small Scale Chamber |
ISO 16000-6:2011 | Indoor air Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID |
ISO Guide 34:2009 | General requirements for the competence of reference material producers |
ASTM D 5197 : 2003 | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ASTM D 5197 : 2009 | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ASTM D 7143 : 2011 | Standard Practice for Emission Cells for the Determination of Volatile Organic Emissions from Indoor Materials/Products |
ASTM D 7706 : 2011 | Standard Practice for Rapid Screening of VOC Emissions from Products Using Micro-Scale Chambers |
ASTM D 6617 : 2000 | Standard Practice for Laboratory Bias Detection Using Single Test Result from Standard Material |
ASTM D 6299 : 2002 | Standard Practice for Applying Statistical Quality Assurance Techniques to Evaluate Analytical Measurement System Performance |
ASTM D 6617 : 2017 | Standard Practice for Laboratory Bias Detection Using Single Test Result from Standard Material |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.